Indicators of the maximum radiation dose to the skin during percutaneous coronary intervention in different target vessels

被引:18
|
作者
Chida, Koichi
Saito, Haruo
Kagaya, Yutaka
Kohzuki, Masahiro
Takai, Yoshihiro
Takahashi, Shoki
Yamada, Shogo
Zuguchi, Masayuki
机构
[1] Tohoku Univ, Fac Med, Sch Hlth Sci, Dept Radiol Technol,Aoba Ku, Sendai, Miyagi 9808575, Japan
[2] Tohoku Univ, Grad Sch Med, Dept Radiol, Sendai, Miyagi 980, Japan
[3] Tohoku Univ, Grad Sch Med, Dept Cardiovasc Med, Sendai, Miyagi 980, Japan
[4] Tohoku Univ, Grad Sch Med, Dept Internal Med & Rehabil Sci, Sendai, Miyagi 980, Japan
关键词
catheterization; coronary intervention; angiography; patient radiation exposure; coronary diseases;
D O I
10.1002/ccd.20830
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To evaluate whether the maximum radiation dose to the patient's skin (MSD) can be estimated during percutaneous coronary intervention (PCI) procedures, we investigated the relationship between the MSD and fluoroscopic time, dose-area product (DAP), and body weight, separately analyzing the relationships for different target vessels. Background: Many cases of skin injury caused by excessive radiation exposure during cardiac intervention procedures have been reported. However, real-time maximum-dose monitoring of the skin is unavailable for many cardiac intervention procedures. Methods: We studied 197 consecutive PCI procedures that involved a single target vessel and were conducted. The DAP was measured, and the MSD was calculated by a skin-dose mapping software program (Caregraph). The target vessels of the PCI procedures were divided into four groups based on the AHA classification system: AHA 5-10, left anterior descending artery domain (LAD), AHA 11-15, left circumflex artery domain (LCx), AHA 1-3 = R 1-3, and AHA 4 = R 4. Results: The correlation coefficient (r) between the MSD and fluoroscopic time was higher for the right coronary artery (RCA) vessels (R 1-3, 0.852; R 4, 0.715) than for the left coronary artery (LCA) vessels (LAD, 0.527; LCx, 0.646), and the r value between the MSD and DAP was higher for the RCA vessels (R 1-3, 0.871; R 4, 0.898) than for the LCA vessels (LAD, 0.628; LCx, 0.694). Similarly, the correlation coefficient between the MSD and weight x fluoroscopic time (WFP) was higher for the RCA vessels (R 1-3, 0.874; R 4, 0.807) than for the LCA vessels (LAD, 0.551; LCx, 0.735). Conclusions: The DAP and WFP can be used to estimate the MSD during PCI in the RCA but not in the LCA, especially the LAD. (C) 2006 Wiley-Liss, Inc.
引用
收藏
页码:236 / 241
页数:6
相关论文
共 50 条
  • [1] Total entrance skin dose: An effective indicator of maximum radiation dose to the skin during percutaneous coronary intervention
    Chida, Koichi
    Kagaya, Yutaka
    Saito, Haruo
    Takai, Yoshihiro
    Takahashi, Shoki
    Yamada, Shogo
    Kohzuki, Masahiro
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (04) : W224 - W227
  • [2] Influence of the target vessel on the location and area of maximum skin dose during percutaneous coronary intervention
    Chida, K.
    Fuda, K.
    Kagaya, Y.
    Saito, H.
    Takai, Y.
    Kohzuki, M.
    Takahashi, S.
    Yamada, S.
    Zuguchi, M.
    ACTA RADIOLOGICA, 2007, 48 (08) : 846 - 850
  • [3] CLINICAL DETERMINANTS OF RADIATION SKIN DOSE IN ADULT PERCUTANEOUS CORONARY INTERVENTION
    Fetterly, Kenneth A.
    Lennon, Ryan J.
    Bell, Malcolm R.
    Holmes, David R., Jr.
    Rihal, Charanjit S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [4] Methods to reduce patients' maximum skin dose during percutaneous coronary intervention for chronic total occlusion
    Suzuki, Shigeru
    Furui, Shigeru
    Isshiki, Takaaki
    Kozuma, Ken
    Koyama, Yutaka
    Ochiai, Masahiko
    Asakura, Yasushi
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 71 (06) : 792 - 798
  • [5] Predictors of Increased Radiation Dose During Percutaneous Coronary Intervention
    Mercuri, Mathew
    Xie, Changchun
    Levy, Michael
    Valettas, Nicholas
    Natarajan, Madhu K.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (09): : 1241 - 1244
  • [6] Patient Radiation Dose During Bifurcation Percutaneous Coronary Intervention
    Rempakos, Athanasios
    Strepkos, Dimitrios
    Carvalho, Pedro
    Mutlu, Deniz
    Alexandrou, Michaella
    Yildirim, Ufuk
    Khelimskii, Dmitrii
    Krestyaninov, Oleg
    Uluganyan, Mahmut
    Kultursay, Barkin
    Mastrodemos, Olga
    Rangan, Bavana
    Al-Ogaili, Ahmed
    Jalli, Sandeep
    Voudris, Konstantinos
    Burke, M. Nicholas
    Sandoval, Yader
    Brilakis, Emmanouil
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B194 - B194
  • [7] Patients' skin dose during percutaneous coronary intervention for chronic total occlusion
    Suzuki, Shigeru
    Furui, Shigeru
    Isshiki, Takaaki
    Kozuma, Ken
    Koyama, Yutaka
    Yamamoto, Hiroyuki
    Ochiai, Masahiko
    Asakura, Yasushi
    Ikari, Yuji
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 71 (02) : 160 - 164
  • [8] Evaluation of peak skin dose during percutaneous coronary intervention procedures: relationship with fluoroscopic pulse rate and target vessel
    Tanaka, Takuro
    Matsubara, Kosuke
    Kobayashi, Satoshi
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (01) : 34 - 40
  • [9] Evaluation of peak skin dose during percutaneous coronary intervention procedures: relationship with fluoroscopic pulse rate and target vessel
    Takuro Tanaka
    Kosuke Matsubara
    Satoshi Kobayashi
    Radiological Physics and Technology, 2021, 14 : 34 - 40
  • [10] Efficacy of radiation dose reduction due to real-time monitoring and visualization of peak skin dose during coronary angiography and percutaneous coronary intervention
    Ichimoto, Eiji
    Kadohira, Tadayuki
    Nakayama, Takashi
    De Gregorio, Joseph
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (04) : 717 - 722