Frequency-constrained multi-source power system scheduling against N-1 contingency and renewable uncertainty

被引:20
|
作者
Yin, Yue [1 ]
Liu, Tianqi [1 ]
Wu, Lei [2 ]
He, Chuan [1 ]
Liu, Yikui [2 ]
机构
[1] Sichuan Univ, Dept Elect Engn, Chengdu 610065, Peoples R China
[2] Stevens Inst Technol, Dept Elect & Comp Engn, Hoboken, NJ 07030 USA
关键词
Generalized benders composition; N-1; contingency; Primary frequency response; Transient frequency-constrained unit commitment; Uncertainty; DEMAND RESPONSE; UNIT COMMITMENT; ENERGY-STORAGE; WIND; CAPACITY; STRATEGIES; OPERATION;
D O I
10.1016/j.energy.2020.119296
中图分类号
O414.1 [热力学];
学科分类号
摘要
Security continues to be the most critical concern in power system operation, which is exceptionally important under low inertia and high uncertainty situations induced by an increasing penetration of renewable sources. This paper presents a transient frequency-constrained two-stage stochastic scheduling model to study the day-ahead operation of thermal-hydro-wind-demand response systems. Specifically, (i) limits on rate-of-change-of-frequency and maximum frequency derivation are introduced to provide sufficient governor reserve from multiple sources for guaranteeing dynamic frequency performance against N-1 contingency; (ii) The de-loaded mode of variable speed wind turbines is proposed for leveraging economics of system operation and security of dynamic frequency response; (iii) Virtual inertial constant of power systems with variable speed wind turbines is calculated to simulate performance of the virtual inertial control; (iv) Demand response is considered in the stochastic framework to mitigate the time delay of delivering virtual inertia. Multiple scenarios are generated via Monte Carlo method to simulate wind generation uncertainties. The proposed two-stage stochastic mixed-integer nonlinear programming model with binaries in both stages is solved via an improved generalized Benders decomposition, which takes about 40% less time than the standard generalized Benders decomposition. Several enhanced strategies are discussed to improve computational performance of the generalized Benders decomposition. Numerical simulations illustrate effectiveness of the proposed approach in coordinating multi-resource scheduling of power systems against N-1 contingencies and uncertainties with guaranteed frequency performance. Specifically, numerical results on the 6-bus system illustrate that: (i) The optimal wind generation penetration level of 40% could well balance the wind curtailments and the benefits of variable speed wind turbines for regulation provision; (ii) With 50% penetration of wind generation, doubling the capacity of demand response can reduce the amount of wind curtailment 50.42%, and decrease the transient frequency deviation to 0.25Hz. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Coordination of Optimal LFC and Digital Frequency Relay for Multi-Source Power System in Egypt
    Mohamed, Emad A.
    Magdy, G.
    Shabib, G.
    Elbaset, Adel A.
    Mitani, Yasunori
    2018 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENERGY SYSTEMS (ICEES), 2018, : 178 - 183
  • [22] Load Frequency Control of a Two Area Multi-source Power System with Electric Vehicle
    Nikhil Saikia
    Nipan Kumar Das
    Journal of Control, Automation and Electrical Systems, 2023, 34 : 394 - 406
  • [23] PEV assisted Primary Frequency Control of a Wind Integrated Multi-Source Power System
    Sarma, Praveen S.
    Chandran, Sunil V.
    Jose, Athul P.
    Deepak, M.
    2022 IEEE INTERNATIONAL POWER AND RENEWABLE ENERGY CONFERENCE, IPRECON, 2022,
  • [24] Load Frequency Control of a Two Area Multi-source Power System with Electric Vehicle
    Saikia, Nikhil
    Das, Nipan Kumar
    JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2023, 34 (02) : 394 - 406
  • [25] Optimal assignment of the battery for the electric power system against N-1 accident
    Watanabe H.
    Takase N.
    Okamoto T.
    Seki K.
    Jintsugawa T.
    Aiyoshi E.
    1600, Institute of Electrical Engineers of Japan (136): : 746 - 757
  • [26] SMES-GCSC Coordination for Frequency and Voltage Regulation in a Multi-Area and Multi-Source Power System with Penetration of Electric Vehicles and Renewable Energy Sources
    Shukla, Hiramani
    Nikolovski, Srete
    Raju, More
    Rana, Ankur Singh
    Kumar, Pawan
    ENERGIES, 2023, 16 (01)
  • [27] Optimized coordinated control of LFC and SMES to enhance frequency stability of a real multi-source power system considering high renewable energy penetration
    Magdy G.
    Shabib G.
    Elbaset A.A.
    Mitani Y.
    Protection and Control of Modern Power Systems, 2018, 3 (1)
  • [28] A Multi-Source Power System's Load Frequency Control Utilizing Particle Swarm Optimization
    Qu, Zhengwei
    Younis, Waqar
    Wang, Yunjing
    Georgievitch, Popov Maxim
    ENERGIES, 2024, 17 (02)
  • [29] Two stage scheduling strategy of multi-source combined power generation system with concentrated solar power participating in adjustment
    Li Q.
    Deng G.
    Zhang J.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (12): : 86 - 92
  • [30] Load Frequency Model Predictive Control of a Large-Scale Multi-Source Power System
    Afaneh, Tayma
    Mohamed, Omar
    Abu Elhaija, Wejdan
    ENERGIES, 2022, 15 (23)