Organ dose conversion coefficients for external photon irradiation using the Chinese voxel phantom (CVP)

被引:12
|
作者
Li, Junli [1 ,2 ,3 ]
Qiu, Rui [1 ,2 ,3 ]
Zhang, Zhan [3 ]
Liu, Liye [3 ]
Zeng, Zhi [1 ,2 ,3 ]
Bi, Lei [3 ]
Li, Wenqian [3 ]
机构
[1] Tsinghua Univ, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
[2] Key Lab High Energy Radiat Imaging Fundamental Sc, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
基金
美国国家科学基金会;
关键词
COLOR PHOTOGRAPHS; VIP-MAN; ADULT; MODEL; BODY; CONSTRUCTION;
D O I
10.1093/rpd/ncp087
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A set of conversion coefficients from kerma free-in-air to the organ absorbed dose are presented for external monoenergetic photon beams from 10 keV to 10 MeV based on a whole-body, Chinese adult male voxel phantom. This computational phantom, called the Chinese voxel phantom (CVP), including totally 23 organs, was developed from magnetic resonance imaging of a young healthy Chinese man at a resolution of 2 x 2 mm. Compared with the ICRP Reference Man, more than half of the organs or tissues in the CVP show mass differences of more than 20. Monte Carlo simulations with MCNP code were carried out to calculate the organ dose conversion coefficients. Irradiation conditions include anterior-posterior, posterior-anterior (PA), right-lateral, left-lateral, rotational and isotropic geometries. Organ dose conversion coefficients from this study are compared with the data from the Asian voxel phantoms Visible Chinese Human and KORMAN. These data sets agree with each other within 10% for photon energy > 5 MeV. However, discrepancies of 34-63% were observed for organs of the alimentary tract, such as the oesophagus and stomach, those of the urinary system, such as the bladder wall and thyroid, especially at low photon energy range and PA geometry. These results suggest that the anatomical variation within the Chinese population, as represented by these adult male voxel phantoms, can lead to uncertainties when a standard phantom is used for the entire population.
引用
收藏
页码:33 / 42
页数:10
相关论文
共 50 条
  • [41] MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam
    Lamyae El Gonnouni
    Tarek El Bardouni
    Mariam Zoubair
    Mohamed Idaomar
    Abderrahmane Senhoo
    原子核物理评论, 2011, 28 (02) : 236 - 240
  • [42] Study On the Dose Conversion Coefficients in Pediatric Radiography with the Development of Children Voxel Phantoms
    Liu, Q.
    Zhuo, W.
    Liu, H.
    Liu, Y.
    Chen, T.
    MEDICAL PHYSICS, 2016, 43 (06) : 3348 - 3348
  • [43] Adult female voxel models of different stature and photon conversion coefficients for radiation protection
    Fill, UA
    Zankl, M
    Petoussi-Henss, N
    Siebert, M
    Regulla, D
    HEALTH PHYSICS, 2004, 86 (03): : 253 - 272
  • [44] Dose conversion coefficients for photon exposure of the human eye lens
    Behrens, R.
    Dietze, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (02): : 415 - 437
  • [45] EVALUATION OF DOSE CONVERSION COEFFICIENTS FOR EXTERNAL EXPOSURE USING TAIWANESE REFERENCE MAN AND WOMAN
    Chang, S. J.
    Hung, S. Y.
    Liu, Y. L.
    Jiang, S. H.
    Wu, J.
    RADIATION PROTECTION DOSIMETRY, 2015, 167 (1-3) : 247 - 250
  • [46] Fluence to organ dose conversion coefficients calculated with the voxel model norman-05 and the MCNPX Monte Carlo code for external monoenergetic photons from 20 kev to 100 mev
    Ferrari, P.
    Gualdrini, G.
    RADIATION PROTECTION DOSIMETRY, 2007, 123 (03) : 295 - 317
  • [47] Calculation of effective dose from external exposure to photons for the Male Adult voXel (MAX) phantom
    Vieira, JW
    Kramer, R
    Lima, FRA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 654 - 657
  • [48] Comparison of Organ and Effective Photon Dose Coefficients for Reference Phantoms in Articulated and Upright Postures in Cranial and Caudal Irradiation Geometries
    Bales, Kathryn
    Dewji, Shaheen
    HEALTH PHYSICS, 2019, 116 (05): : 599 - 606
  • [49] THE NEUTRON DOSE CONVERSION COEFFICIENTS CALCULATION IN HUMAN TOOTH ENAMEL IN AN ANTHROPOMORPHIC PHANTOM
    Khailov, A. M.
    Ivannikov, A. I.
    Skvortsov, V. G.
    Stepanenko, V. F.
    Tsyb, A. F.
    Trompier, F.
    Hoshi, M.
    HEALTH PHYSICS, 2010, 98 (02): : 369 - 377
  • [50] New estimation of electron and photon internal dose coefficients for new adult female computational phantom using DoseCalcs
    El Ghalbzouri, Tarik
    El Bardouni, Tarek
    El Bakkali, Jaafar
    El-Bouzaidi, Mohamed Drissi
    Satti, Hicham
    RADIATION PHYSICS AND CHEMISTRY, 2025, 234