Organ dose conversion coefficients for external photon irradiation using the Chinese voxel phantom (CVP)

被引:12
|
作者
Li, Junli [1 ,2 ,3 ]
Qiu, Rui [1 ,2 ,3 ]
Zhang, Zhan [3 ]
Liu, Liye [3 ]
Zeng, Zhi [1 ,2 ,3 ]
Bi, Lei [3 ]
Li, Wenqian [3 ]
机构
[1] Tsinghua Univ, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
[2] Key Lab High Energy Radiat Imaging Fundamental Sc, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
基金
美国国家科学基金会;
关键词
COLOR PHOTOGRAPHS; VIP-MAN; ADULT; MODEL; BODY; CONSTRUCTION;
D O I
10.1093/rpd/ncp087
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A set of conversion coefficients from kerma free-in-air to the organ absorbed dose are presented for external monoenergetic photon beams from 10 keV to 10 MeV based on a whole-body, Chinese adult male voxel phantom. This computational phantom, called the Chinese voxel phantom (CVP), including totally 23 organs, was developed from magnetic resonance imaging of a young healthy Chinese man at a resolution of 2 x 2 mm. Compared with the ICRP Reference Man, more than half of the organs or tissues in the CVP show mass differences of more than 20. Monte Carlo simulations with MCNP code were carried out to calculate the organ dose conversion coefficients. Irradiation conditions include anterior-posterior, posterior-anterior (PA), right-lateral, left-lateral, rotational and isotropic geometries. Organ dose conversion coefficients from this study are compared with the data from the Asian voxel phantoms Visible Chinese Human and KORMAN. These data sets agree with each other within 10% for photon energy > 5 MeV. However, discrepancies of 34-63% were observed for organs of the alimentary tract, such as the oesophagus and stomach, those of the urinary system, such as the bladder wall and thyroid, especially at low photon energy range and PA geometry. These results suggest that the anatomical variation within the Chinese population, as represented by these adult male voxel phantoms, can lead to uncertainties when a standard phantom is used for the entire population.
引用
收藏
页码:33 / 42
页数:10
相关论文
共 50 条
  • [21] Organ and effective dose conversion coefficients for a sitting female hybrid computational phantom exposed to monoenergetic protons in idealized irradiation geometries
    Alves, M. C.
    Santos, W. S.
    Lee, Choonsik
    Bolch, Wesley E.
    Hunt, John G.
    Carvalho Junior, A. B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (24): : 7957 - 8003
  • [22] Evaluation of the fluence to dose conversion coefficients for high energy neutrons using a voxel phantom coupled with the GEANT4 code
    Paganini, S
    Vilela, E
    BRAZILIAN JOURNAL OF PHYSICS, 2005, 35 (3B) : 818 - 820
  • [23] Comparison of Monoenergetic Photon Organ Dose Rate Coefficients for the Female Stylized and Voxel Phantoms Submerged in Air
    Hiller, Mauritius
    Dewji, Shaheen Azim
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) : 336 - 343
  • [24] CALCULATION OF THE DOSE CONVERSION COEFFICIENTS FOR CHINESE EYE LENS UNDER PHOTON EXPOSURE
    Teng, Zhongbin
    Song, Mingzhe
    Liu, Senlin
    Wei, Kexin
    Liu, Yuntao
    RADIATION PROTECTION DOSIMETRY, 2021, 197 (3-4) : 163 - 174
  • [25] Dose conversion coefficients for ICRP110 voxel phantom in the Geant4 Monte Carlo code
    Martins, M. C.
    Cordeiro, T. P. V.
    Silva, A. X.
    Souza-Santos, D.
    Queiroz-Filho, P. P.
    Hunt, J. G.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 309 - 312
  • [26] Preliminary studies on neutron conversion coefficients calculated with MCNPX in NORMAN voxel phantom
    Gualdrini, G.
    Ferrari, P.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 449 - 452
  • [27] Increasing organ dose accuracy through voxel phantom organ matching with individual patient anatomy
    Borbinha, Jorge
    Di Maria, Salvatore
    Madeira, Paula
    Belchior, Ana
    Baptista, Mariana
    Vaz, Pedro
    RADIATION PHYSICS AND CHEMISTRY, 2019, 159 : 35 - 46
  • [28] Absorbed dose rate conversion coefficients for reference terrestrial biota for external photon and internal exposures
    Taranenko, V
    Pröhl, G
    Gómez-Ros, JM
    JOURNAL OF RADIOLOGICAL PROTECTION, 2004, 24 (4A) : A35 - A62
  • [29] A comparison between GATE and MCNPX for photon dose calculations in radiation protection using a male voxel phantom
    Cui, Tiantian
    Li, Zhanpeng
    Zhang, Shuyuan
    Wang, Yidi
    Chen, Dandan
    Sun, Liang
    RADIATION PHYSICS AND CHEMISTRY, 2019, 157 : 47 - 53
  • [30] Neutron-fluence-to-dose conversion coefficients in an anthropomorphic phantom
    Alghamdi, AA
    Ma, A
    Tzortzis, M
    Spyrou, NM
    RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 606 - 611