Effect of central corneal thickness on intraocular pressure and comparison of Topcon CT-80 non-contact tonometry with Goldmann applanation tonometry

被引:22
|
作者
Mansoori, Tarannum [1 ]
Balakrishna, Nagalla [2 ]
机构
[1] Anand Eye Inst, Dept Glaucoma, Hyderabad, Andhra Pradesh, India
[2] Natl Inst Nutr, Dept Stat, Hyderabad, Andhra Pradesh, India
关键词
central corneal thickness; Goldmann applanation tonometer; Topcon CT-80 NCT; PNEUMOTONOMETER; AGREEMENT;
D O I
10.1111/cxo.12620
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To compare intraocular pressure (IOP) measurements obtained with the Topcon CT-80 non-contact tonometer (NCT) and Goldmann applanation tonometer (GAT), in different ranges of IOP in normal and glaucoma subjects, and to assess the influence of central corneal thickness (CCT) on the IOP measurements in Asian Indian eyes. Methods: Four hundred and two eyes of 402 subjects (193 newly diagnosed primary open angle glaucoma [POAG] and 209 normal) were enrolled for this prospective study. For each eye, IOP was measured with GAT by a glaucoma specialist and NCT by a trained optometrist. The IOP values were compared among the tonometers in the three different IOP ranges (<= 12 mmHg, 13-20 mmHg and >= 21 mmHg) using Bland-Altman graphs. Correlation between GAT and NCT was assessed by Pearson correlation co-efficient. CCT was measured with ultrasound pachymetry and its correlation with GAT and NCT was analysed using linear regression analysis. Results: The mean paired difference of IOP between NCT and GAT was 1.556 +/- 2.69 mmHg (r = 0.26, p = 0.006) at IOP range of <= 12 mmHg, -1.665 +/- 2.6 mmHg (r = 0.51, p < 0.0001) in IOP range of 13-20 mmHg and -2.202 +/- 3.44 mmHg (r = 0.82, p < 0.0001) in the IOP range of >= 21 mmHg. Linear regression analysis showed a mean IOP variation of 0.27 mmHg per 10 m change in CCT for NCT (p < 0.0001) and IOP change of 0.19 mmHg per 10 mu m change in CCT for GAT (p = 0.01). Conclusion: In this study of normotensive and POAG subjects, the Topcon CT-80 NCT showed an overestimation of IOP at the lower range and underestimation of IOP in normal and higher ranges of IOP. Clinicians should keep in mind that CCT influences IOP measurement with both types of tonometer and that the IOP readings obtained with these tonometers are not interchangeable.
引用
收藏
页码:206 / 212
页数:7
相关论文
共 50 条
  • [21] Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients
    Vincent, Stephen J.
    Vincent, Roslyn A.
    Shields, David
    Lee, Graham A.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (04): : E163 - E170
  • [22] Comparative evaluation of TonoPen AVIA, Goldmann applanation tonometry and non-contact tonometry
    Bhartiya S.
    Bali S.J.
    Sharma R.
    Chaturvedi N.
    Dada T.
    International Ophthalmology, 2011, 31 (4) : 297 - 302
  • [23] Correlation Between Goldmann Applanation Tonometry and Rebound Tonometry in Relation to Central Corneal Thickness
    Brandtner, H.
    Hitzl, W.
    Strohmaier, C.
    Abri, S.
    Wintersteller, C.
    Hohensinn, M.
    Ruckhofer, J.
    Stoiber, J.
    Grabner, G.
    Reitsamer, H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [24] Comparison of Goldmann Applanation Tonometry and Dynamic Contour Tonometry in the Measurement of Intraocular Pressure in Eyes with Different Corneal Thicknesses
    Roszkowska, A. M.
    De Grazia, L.
    Cirone, M.
    Ferreri, G.
    OPHTHALMOLOGICA, 2009, 223 (04) : 244 - 249
  • [25] Comparison of dynamic contour tonometry and Goldmann applanation tonometry in relation to central corneal thickness in primary congenital glaucoma
    Marcelo Lopes Silva Jordão
    Vital Paulino Costa
    Maria de Lourdes Veronese Rodrigues
    Jayter Silva Paula
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 : 117 - 121
  • [26] Effects of central corneal thickness, central corneal power, and axial length on intraocular pressure measurement assessed with goldmann applanation tonometry
    Oezcura, Fatih
    Aydin, Sayime
    Uzgoeren, Nevin
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2008, 52 (05) : 353 - 356
  • [27] Effects of central corneal thickness, central corneal power, and axial length on intraocular pressure measurement assessed with goldmann applanation tonometry
    Fatih Özcura
    Sayime Aydın
    Nevin Uzgören
    Japanese Journal of Ophthalmology, 2008, 52 : 353 - 356
  • [28] Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry
    J Y F Ku
    H V Danesh-Meyer
    J P Craig
    G D Gamble
    C N J McGhee
    Eye, 2006, 20 : 191 - 198
  • [29] Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry
    Ku, JYF
    Danesh-Meyer, HV
    Craig, JP
    Gamble, GD
    McGhee, CNJ
    EYE, 2006, 20 (02) : 191 - 198
  • [30] Comparison of dynamic contour tonometry and Goldmann applanation tonometry in relation to central corneal thickness in primary congenital glaucoma
    Silva Jordao, Marcelo Lopes
    Costa, Vital Paulino
    Veronese Rodrigues, Maria de Lourdes
    Paula, Jayter Silva
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (01) : 117 - 121