Maximum Entropy Based Non-Negative Optoacoustic Tomographic Image Reconstruction

被引:31
|
作者
Prakash, Jaya [1 ]
Mandal, Subhamoy [2 ,3 ]
Razansky, Daniel [2 ,4 ]
Ntziachristos, Vasilis [2 ,5 ]
机构
[1] Inst Biol & Med Imaging, Oberschleissheim, Germany
[2] Helmholtz Zentrum Munchen, Inst Biol & Med Imaging, D-85764 Munich, Germany
[3] Tech Univ Munich, Dept Elect & Comp Engn, Munich, Germany
[4] Tech Univ Munich, Sch Med, Munich, Germany
[5] Tech Univ Munich, Chair Biol Imaging, D-81675 Munich, Germany
基金
欧洲研究理事会; 美国国家卫生研究院;
关键词
Optical parameters; photoacoustic tomography; inverse problems; image reconstruction; regularization theory; PHOTOACOUSTIC TOMOGRAPHY; OPTICAL-ABSORPTION; REGULARIZATION; INVERSION; DISTRIBUTIONS; OXYGENATION; TISSUES;
D O I
10.1109/TBME.2019.2892842
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Optoacoustic (photoacoustic) tomography is aimed at reconstructing maps of the initial pressure rise induced by the absorption of light pulses in tissue. In practice, due to inaccurate assumptions in the forward model, noise, and other experimental factors, the images are often afflicted by artifacts, occasionally manifested as negative values. The aim of this work is to develop an inversion method which reduces the occurrence of negative values and improves the quantitative performance of optoacoustic imaging. Methods: We present a novel method for optoacoustic tomography based on an entropy maximization algorithm, which uses logarithmic regularization for attaining non-negative reconstructions. The reconstruction image quality is further improved using structural prior-based fluence correction. Results: We report the performance achieved by the entropy maximization scheme on numerical simulation, experimental phantoms, and in-vivo samples. Conclusion: The proposed algorithm demonstrates superior reconstruction performance by delivering non-negative pixel values with no visible distortion of anatomical structures. Significance: Our method can enable quantitative optoacoustic imaging, and has the potential to improve preclinical and translational imaging applications.
引用
收藏
页码:2604 / 2616
页数:13
相关论文
共 50 条
  • [41] Maximum entropy Kalman filter for image reconstruction and compression
    Avesta, N
    Aboulnasr, T
    JOURNAL OF ELECTRONIC IMAGING, 2004, 13 (04) : 738 - 755
  • [42] Non-negative source separation using the maximum likelihood approach
    Moussaoui, Said
    Brie, David
    Carteret, Cedric
    2005 IEEE/SP 13TH WORKSHOP ON STATISTICAL SIGNAL PROCESSING (SSP), VOLS 1 AND 2, 2005, : 1043 - 1048
  • [43] Wigner non-negative states that verify the Wigner entropy conjecture
    Qian, Qipeng
    Gagatsos, Christos N.
    PHYSICAL REVIEW A, 2024, 110 (01)
  • [44] Non-negative differentially constrained entropy-like regularization
    Landl, G
    Anderssen, RS
    INVERSE PROBLEMS, 1996, 12 (01) : 35 - 53
  • [45] Rain Removal Using Single Image based on Non-negative Matrix Factorization
    Liu, Pin-Hsian
    Lin, Chih-Yang
    Yeh, Chia-Hung
    Kang, Li-Wei
    Lo, Kyle Shih-Huang
    Hwang, Tai-Hwei
    Kuo, Chia-Chen
    INTELLIGENT SYSTEMS AND APPLICATIONS (ICS 2014), 2015, 274 : 1137 - 1146
  • [46] Reconstruction of Tomographic Images from a Few Views by New Maximum Entropy Approach
    CHEN Shao-hua (College of Phys. & Electron. Techn.
    SemiconductorPhotonicsandTechnology, 2000, (04) : 200 - 203
  • [47] Multi-focus image fusing based on non-negative matrix factorization
    Xu, Le
    Dong, Ji-yang
    Cai, Cong-bo
    Chen, Zhong
    14TH INTERNATIONAL CONFERENCE ON MECHATRONICS AND MACHINE VISION IN PRACTICE 2007, PROCEEDINGS, 2007, : 108 - +
  • [48] Image Fusion Based on Non-negative Matrix Factorization and Infrared Feature Extraction
    Mou, Jiao
    Gao, Wei
    Song, Zongxi
    2013 6TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP), VOLS 1-3, 2013, : 1046 - 1050
  • [49] Supervised non-negative matrix factorization based latent semantic image indexing
    梁栋
    杨杰
    常宇畴
    Chinese Optics Letters, 2006, (05) : 272 - 274
  • [50] Analysis of the Security of Perceptual Image Hashing Based on Non-Negative Matrix Factorization
    Khelifi, Fouad
    Jiang, Jianmin
    IEEE SIGNAL PROCESSING LETTERS, 2010, 17 (01) : 43 - 46