Pentacam Scheimpflug Tomography Findings in Topographically Normal Patients and Subclinical Keratoconus Cases

被引:105
|
作者
Ruiseor Vazquez, Pablo R. [1 ,2 ]
David Galletti, Jonatan [1 ,2 ]
Minguez, Natalia [1 ,2 ]
Delrivo, Marianella [1 ]
Fuentes Bonthoux, Fernando [1 ]
Pfortner, Tomas [1 ]
Gaston Galletti, Jeremias [1 ,3 ]
机构
[1] EGOS Clin Ocular Studies Lab, Buenos Aires, DF, Argentina
[2] Univ Buenos Aires, Div Ophthalmol, Hosp Clin Jose San Martin, Buenos Aires, DF, Argentina
[3] Natl Acad Med, CONICET, Inst Expt Med, Buenos Aires, DF, Argentina
关键词
POSTERIOR CORNEAL ELEVATION; NORMAL EYES; THICKNESS; PARAMETERS; ECTASIA; VOLUME; SHAPE;
D O I
10.1016/j.ajo.2014.03.018
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate Pentacam ectasia detection indices in topographically normal patients and in subclinical keratoconus cases. DESIGN: Prospective, observational case series. METHODS: SETTING: Institutional. PATIENTS: Group 1 comprised 1 eye from 189 patients with unremarkable topography and Groups 2 and 3 included the better and worse eyes, respectively, of 55 keratoconic patients. Group 2 eyes with normal topography (n = 37) were considered subclinical keratoconus cases. OBSERVATION PROCEDURE: Pentacam Scheimpflug tomography. MAIN OUTCOME MEASURES: Eleven Pentacam ectasia detection indices. RESULTS: All Pentacam ectasia indices significantly differed between Groups 1 and 2 and were correlated with keratoconus grade. Only 99 eyes (52%) in Group 1 had normal values for every index, whereas 7 subclinical keratoconus eyes (19%) showed 2 or fewer abnormal indices. Standardized relational thickness and overall deviation indices had 73% and 89% sensitivity for subclinical keratoconus, respectively. Both average and maximum pachymetric progression indices offered 84% sensitivity while maximum relational thickness index showed 78% sensitivity for subclinical keratoconus. Optimized cutoff values for subclinical keratoconus increased the sensitivity of the standardized and maximum relational thickness indices. CONCLUSION: Pentacam Scheimpflug tomography can detect most subclinical keratoconus cases with unremarkable topography, but performance is not as good as reported and varies considerably for each index. The overall deviation, average and maximum pachymetric progression, and maximum relational thickness indices offer the highest sensitivity, which can be improved by using optimized cutoff values. Specificity constitutes an issue for some indices and up to 10% of subclinical keratoconus cases may go undetected by this technology. (Am J Ophthalmol 2014;158:32-40. (C) 2014 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:32 / 40
页数:9
相关论文
共 50 条
  • [1] Pentacam Scheimpflug Tomography Findings in Topographically Normal Patients and Subclinical Keratoconus Cases
    Jia, Yan
    Zhu, Haobin
    Zhou, Jibo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (01) : 209 - 209
  • [2] Subclinical Keratoconus Detection Based On Pentacam Scheimpflug Tomography Indices
    Ruisenor Vazquez, Pablo
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfortner, Tomas
    Chiaradia, Pablo
    Galletti, Jeremias
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [3] Evaluation of Scheimpflug Tomography Parameters in Subclinical Keratoconus, Clinical Keratoconus, and Normal Caucasian Eyes
    Huseynli, Samira
    Abdulaliyeva, Farah
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2018, 48 (03): : 99 - 108
  • [4] Corneal Asymmetry Analysis by Pentacam Scheimpflug Tomography for Keratoconus Diagnosis
    Galletti, Jonatan D.
    Ruisenor Vazquez, Pablo R.
    Minguez, Natalia
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfoertner, Tomas
    Galletti, Jeremias G.
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (02) : 116 - +
  • [5] Keratoconus detection by corneal asymmetry analysis with Pentacam Scheimpflug tomography
    David Galletti, Jonatan
    Ruisenor Vazquez, Pablo Raul
    Ximena Minguez, Natalia
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfortner, Tomas
    Gaston Galletti, Jeremias
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [6] Pentacam Scheimpflug Tomography Findings in Chinese Patients With Different Corneal Diameters
    Ding, Lan
    Wang, Jifang
    Niu, Lingling
    Shi, Wanru
    Qian, Yishan
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (10) : 688 - +
  • [7] Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes
    Ucakhan, Omur O.
    Cetinkor, Volkan
    Ozkan, Muhip
    Kanpolat, Ayfer
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1116 - 1124
  • [8] Correlation of the KISA% index and Scheimpflug tomography in 'normal', 'subclinical', 'keratoconus-suspect' and 'clinically manifest' keratoconus eyes
    Steinberg, Johannes
    Aubke-Schultz, Silke
    Frings, Andreas
    Huelle, Jan
    Druchkiv, Vasyl
    Richard, Gisbert
    Katz, Toam
    Linke, Stephan J.
    ACTA OPHTHALMOLOGICA, 2015, 93 (03) : e199 - e207
  • [9] Corneal changes in time in normal and keratoconic patients assessed by Pentacam Scheimpflug tomography
    Ximena Minguez, Natalia
    Ruisenor Vazquez, Pablo Raul
    David Galletti, Jonatan
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfortner, Tomas
    Gaston Galletti, Jeremias
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [10] Agreement of Corrected Intraocular Pressure Values Between Corvis ST and Pentacam in Patients With Keratoconus, Subclinical Keratoconus, and Normal Cornea
    Chen, Yanhui
    Rong, Hua
    Liu, Wei
    Liu, Guihua
    Du, Bei
    Jin, Chengcheng
    Wei, Ruihua
    CORNEA, 2021, 40 (11) : 1426 - 1432