Non-invasive measurement of cardiac output: Evaluation of new infrared absorption spectrometer

被引:2
|
作者
Baum, M. M.
Moss, J. A.
Kumar, S.
Wagner, P. D.
机构
[1] Oak Crest Inst Sci, Dept Chem, Pasadena, CA 91107 USA
[2] Univ Calif San Diego, Sch Med, Div Physiol, La Jolla, CA 92093 USA
关键词
infrared spectroscopy; open-circuit; inert gas;
D O I
10.1016/j.resp.2005.09.010
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The mass spectrometer (MS) traditionally has been the instrument of choice for measuring cardiac Output (Q(T)) non-invasively using the foreign gas uptake method. However, the size and cost of the MS has hampered widespread adoption of this technique outside of the laboratory. Here, we present results, from six normal human subjects at rest and during exercise, of simultaneous QT measurements by an MS and a new, portable infrared (IR) device developed in our laboratories. These measurements are made using on the open-circuit acetylene uptake method. The IR device measures inspired and end-tidal concentrations of acetylene, sulfur hexafluoride, and carbon dioxide by IR absorption spectroscopy with a 10-90% response time of 43 ms; accurate measurements were made down to sample flow rates of 50 mL min(-1). Excellent correlation [Q(T) (IR) = 0-98 QT (MS), R-2 = 0.94] was observed between instruments across the range from rest to heavy exercise. These results suggest that the IR device, which is small, light-weight, and rugged may enable the foreign gas uptake method to be used in clinical, field, and point-of-care settings for QT measurement. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 50 条
  • [41] Non-invasive measurements of cardiac output after cardiac surgery
    Ludwik Fedorko
    David Preiss
    Joseph Fisher
    George Djaiani
    Jo Carroll
    L. Minkovich
    Azami Takafumi
    George Volgyesi P. Eng.
    Canadian Journal of Anesthesia, 2005, 52 (Suppl 1): : A88 - A88
  • [42] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY A SINGLE BREATH CONSTANT EXPIRATORY TECHNIQUE
    CORRIS, P
    GIBSON, J
    THORAX, 1984, 39 (12) : 958 - 958
  • [43] Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique
    Gabrielsen, A
    Videbæk, R
    Schou, M
    Damgaard, M
    Kastrup, J
    Norsk, P
    CLINICAL SCIENCE, 2002, 102 (02) : 247 - 252
  • [44] Validation of a non-invasive cardiac output measurement using exhaled carbon dioxide in children
    Levy, RJ
    Nicolson, SC
    Lin, RJ
    Chiavacci, R
    Helfaer, MA
    Nadkarni, VM
    CRITICAL CARE MEDICINE, 2002, 30 (12) : A161 - A161
  • [45] Non-Invasive Cardiac Output Monitoring by Aortic Blood Flow Measurement With the Dynemo 3000
    Jean-Luc G. Boulnois
    Thierry Pechoux
    Journal of Clinical Monitoring and Computing, 2000, 16 : 127 - 140
  • [46] Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care
    Bataille, B.
    Bertuit, M.
    Mora, M.
    Mazerolles, M.
    Cocquet, P.
    Masson, B.
    Moussot, P. E.
    Ginot, J.
    Silva, S.
    Larche, J.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (06) : 879 - 886
  • [47] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY A SINGLE BREATH CONSTANT EXPIRATORY TECHNIQUE
    ELKAYAM, U
    WILSON, AF
    MORRISON, J
    MELTZER, P
    DAVIS, J
    KLOSTERMAN, P
    LOUVIER, J
    HENRY, WL
    THORAX, 1984, 39 (02) : 107 - 113
  • [48] NON-INVASIVE ULTRASONIC CARDIAC-OUTPUT MEASUREMENT IN INTENSIVE-CARE UNIT
    LEVY, BI
    PAYEN, DM
    TEDGUI, A
    XHAARD, M
    MCILROY, MB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (06): : 841 - 849
  • [49] Non-invasive measurement of cardiac output using AESCULON® mini after Fontan operation
    Yoshitake, Shuichi
    Miyamoto, Takashi
    Tanaka, Yuki
    Naito, Yuji
    PEDIATRICS INTERNATIONAL, 2017, 59 (02) : 141 - 144
  • [50] Non-invasive measurement of cardiac output using an iterative, respiration-based method
    Klein, M.
    Minkovich, L.
    Machina, M.
    Selzner, M.
    Spetzler, V. N.
    Knaak, J. M.
    Roy, D.
    Duffin, J.
    Fisher, J. A.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 114 (03) : 406 - 413