Non-invasive measurement of cardiac output: Evaluation of new infrared absorption spectrometer

被引:2
|
作者
Baum, M. M.
Moss, J. A.
Kumar, S.
Wagner, P. D.
机构
[1] Oak Crest Inst Sci, Dept Chem, Pasadena, CA 91107 USA
[2] Univ Calif San Diego, Sch Med, Div Physiol, La Jolla, CA 92093 USA
关键词
infrared spectroscopy; open-circuit; inert gas;
D O I
10.1016/j.resp.2005.09.010
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The mass spectrometer (MS) traditionally has been the instrument of choice for measuring cardiac Output (Q(T)) non-invasively using the foreign gas uptake method. However, the size and cost of the MS has hampered widespread adoption of this technique outside of the laboratory. Here, we present results, from six normal human subjects at rest and during exercise, of simultaneous QT measurements by an MS and a new, portable infrared (IR) device developed in our laboratories. These measurements are made using on the open-circuit acetylene uptake method. The IR device measures inspired and end-tidal concentrations of acetylene, sulfur hexafluoride, and carbon dioxide by IR absorption spectroscopy with a 10-90% response time of 43 ms; accurate measurements were made down to sample flow rates of 50 mL min(-1). Excellent correlation [Q(T) (IR) = 0-98 QT (MS), R-2 = 0.94] was observed between instruments across the range from rest to heavy exercise. These results suggest that the IR device, which is small, light-weight, and rugged may enable the foreign gas uptake method to be used in clinical, field, and point-of-care settings for QT measurement. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 50 条
  • [31] Non-invasive monitoring of cardiac output - Reply
    Huber, T
    Segiet, W
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1998, 39 (02): : 102 - 103
  • [32] Non-invasive Cardiac Output Monitoring in Neonates
    O'Neill, Roisin
    Dempsey, Eugene M.
    Garvey, Aisling A.
    Schwarz, Christoph E.
    FRONTIERS IN PEDIATRICS, 2021, 8
  • [33] Non-invasive cardiac output and oxygen delivery measurement in an infant with critical anemia
    Garry M. Steil
    Olive S. Eckstein
    Julie Caplow
    Michael S. D. Agus
    Brian K. Walsh
    Jackson Wong
    Journal of Clinical Monitoring and Computing, 2011, 25 : 113 - 119
  • [34] Using non-invasive cardiac output measurement in a protocol of weaning of Novacor LVAD
    Bubenek, S
    Miclea, I
    Stelian, E
    Timofiev, L
    Boros, C
    Mitcov, D
    Candea, V
    Moldovan, H
    Tulbure, D
    INTENSIVE CARE MEDICINE, 2003, 29 : S106 - S106
  • [35] NON-INVASIVE CARDIAC OUTPUT AND OXYGEN DELIVERY MEASUREMENT IN AN INFANT WITH CRITICAL ANEMIA
    Steil, Garry M.
    Eckstein, Olive S.
    Caplow, Julie
    Agus, Michael S. D.
    Walsh, Brian K.
    Wong, Jackson
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2011, 25 (02) : 113 - 119
  • [36] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY ELECTRICAL-IMPEDANCE CARDIOGRAPHY
    SINGH, JB
    HAFTY, B
    PEURA, R
    DUTTA, D
    KOTILAINEN, P
    CLINICAL RESEARCH, 1976, 24 (03): : A240 - A240
  • [37] Non-invasive measurement of cardiac output during coronary artery bypass grafting
    Cohen, AJ
    Arnaudov, D
    Zabeeda, D
    Schultheis, L
    Lashinger, J
    Schachner, A
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 14 (01) : 64 - 69
  • [38] Comparison of a new non-invasive cardiac output technique with invasive bolus and continuous thermodilution
    Watt, RC
    Loeb, RG
    Orr, J
    ANESTHESIOLOGY, 1998, 89 (3A) : U406 - U406
  • [39] Influence of systemic vascular resistance on cardiac output measured by new non-invasive cardiac output monitor
    K Yamashita
    T Yamatabe
    H Abe
    M Yokoyama
    Critical Care, 14 (Suppl 1):
  • [40] EVALUATION OF THE CO2 REBREATHING METHOD FOR THE NON-INVASIVE MEASUREMENT OF RESTING CARDIAC-OUTPUT IN MAN
    HARGREAVES, M
    JENNINGS, G
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1983, 10 (05) : 609 - 614