Non-invasive measurement of cardiac output: Evaluation of new infrared absorption spectrometer

被引:2
|
作者
Baum, M. M.
Moss, J. A.
Kumar, S.
Wagner, P. D.
机构
[1] Oak Crest Inst Sci, Dept Chem, Pasadena, CA 91107 USA
[2] Univ Calif San Diego, Sch Med, Div Physiol, La Jolla, CA 92093 USA
关键词
infrared spectroscopy; open-circuit; inert gas;
D O I
10.1016/j.resp.2005.09.010
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The mass spectrometer (MS) traditionally has been the instrument of choice for measuring cardiac Output (Q(T)) non-invasively using the foreign gas uptake method. However, the size and cost of the MS has hampered widespread adoption of this technique outside of the laboratory. Here, we present results, from six normal human subjects at rest and during exercise, of simultaneous QT measurements by an MS and a new, portable infrared (IR) device developed in our laboratories. These measurements are made using on the open-circuit acetylene uptake method. The IR device measures inspired and end-tidal concentrations of acetylene, sulfur hexafluoride, and carbon dioxide by IR absorption spectroscopy with a 10-90% response time of 43 ms; accurate measurements were made down to sample flow rates of 50 mL min(-1). Excellent correlation [Q(T) (IR) = 0-98 QT (MS), R-2 = 0.94] was observed between instruments across the range from rest to heavy exercise. These results suggest that the IR device, which is small, light-weight, and rugged may enable the foreign gas uptake method to be used in clinical, field, and point-of-care settings for QT measurement. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 50 条
  • [1] Model for non-invasive cardiac output measurement
    Wassertheurer, Siegfried
    Mayer, Christopher
    Breitenecker, Felix
    AMS 2007: FIRST ASIA INTERNATIONAL CONFERENCE ON MODELLING & SIMULATION ASIA MODELLING SYMPOSIUM, PROCEEDINGS, 2007, : 580 - +
  • [2] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT
    LASZLO, G
    BOONZAIER, D
    WELLS, PNT
    BIOMEDICAL ENGINEERING, 1974, 9 (08): : 362 - 364
  • [3] NON-INVASIVE CARDIAC-OUTPUT MEASUREMENT
    MACKAY, RS
    MICROVASCULAR RESEARCH, 1972, 4 (04) : 438 - &
  • [4] A novel approach to non-invasive measurement of cardiac output
    Klein, Michael
    Machina, Matt
    Battisti, Anne
    Pucci, Olivia
    Minkovich, Leonid
    Duffin, James
    Fisher, Joseph
    FASEB JOURNAL, 2011, 25
  • [5] NON-INVASIVE DOPPLER MEASUREMENT OF CARDIAC-OUTPUT
    TOUCHE, T
    NITENBERG, A
    LAFFAY, N
    DAHAN, M
    PRASQUIER, R
    PRESSE MEDICALE, 1984, 13 (27): : 1687 - 1692
  • [6] NON-INVASIVE METHOD FOR THE MEASUREMENT OF CARDIAC-OUTPUT
    NARUMI, J
    SUMA, K
    OHE, Y
    IWABUCHI, K
    UCHIYAMA, A
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1982, 46 (08): : 801 - 802
  • [7] Reliability of non-invasive cardiac output measurement in individuals with tetraplegia
    S Hostettler
    J Brechbühl
    L Leuthold
    G Mueller
    S K Illi
    C M Spengler
    Spinal Cord, 2011, 49 : 665 - 671
  • [8] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT DURING LAPAROSCOPY
    MCKENZIE, R
    WADHWA, RK
    BEDGER, RC
    JOURNAL OF REPRODUCTIVE MEDICINE, 1980, 24 (06) : 247 - 250
  • [9] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY ULTRASONIC METHODS
    TERUYA, H
    IWAHASHI, K
    KUREHA, M
    NAKAYAMA, N
    KUNO, A
    NAKATSUKA, T
    YOSHIMURA, S
    FURUHATA, H
    HORISAKA, R
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1981, 45 (08): : 942 - 942
  • [10] End Tidal Oxygen: A Non-Invasive Measurement of Cardiac Output
    Singer, D. J.
    Russell, J.
    Caputo, N.
    ANNALS OF EMERGENCY MEDICINE, 2019, 74 (04) : S138 - S138