Accuracy of tibial component positioning in the robotic arm assisted versus conventional unicompartmental knee arthroplasty

被引:8
|
作者
Thilak, Jai [1 ]
Thadi, Mohan [1 ]
Mane, Prajwal P. [1 ]
Sharma, Anubhav [1 ]
Mohan, Vipin [1 ]
Babu, Balu C. [1 ]
机构
[1] Amrita Inst Med Sci, Kochi 682041, Kerala, India
关键词
Unicompartmental; Partial knee arthroplasty; Robotic-assisted surgery; Osteoarthritis; Haptic guidance; COMPUTER NAVIGATION; EARLY FAILURE; REPLACEMENT; ALIGNMENT; IMPLANTATION; REVISION; PATIENT;
D O I
10.1016/j.jor.2020.08.022
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Our study aims to determine the planned accuracy of the tibial component placement in robotic arm assisted unicompartmental knee arthroplasty (UKA) versus the conventional jig based UKA of the initial cases done in India for the first time with this particular robotic system. Materials & Methods: Study group 1 consisted of patients who underwent robotic arm (MAKO, Stryker, USA) assisted UKA. Group 2 consists of patients who underwent a standard conventional jig based (Oxford knee, Biomet, UK). Post-operative radiographs were taken to determine the Tibial Implant position and orientation which were compared to their preoperative plan respectively by two independent observers. The mean error value was obtained for both study groups respectively and compared to determine the accuracy of the postoperative tibial implant placement. Results: In the Robotic arm assisted UKA, the deviation of post-operative varus angle from preoperative planned angle was about 0.43 degrees and post-operative Tibial slope alignment differed from preoperative plan was 0.41 degrees. In the Conventional UKA group post-operative varus angle differed from preoperative planned angle by about 2.12 degrees and post-operative Tibial slope alignment deviation from preoperative plan was 2.47 degrees. Conclusions: Robotic arm assisted system was more accurate compared to the conventional jig-based technique in achieving the planned orientation and alignment of the tibial implant in the initial learning phase of this particular Robotic System used for the first time in India. Mesh terms: partial knee replacement, robotic assisted surgery.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 50 条
  • [21] Robotic Arm-Assisted Lateral Unicompartmental Knee Arthroplasty: How Are Components Aligned?
    Zambianchi, Francesco
    Franceschi, Giorgio
    Banchelli, Federico
    Marcovigi, Andrea
    Ensini, Andrea
    Catani, Fabio
    JOURNAL OF KNEE SURGERY, 2022, 35 (11) : 1214 - 1222
  • [22] Robotic-Assisted Versus Manual Unicompartmental Knee Arthroplasty: A Systematic Review
    Iturriaga, Cesar
    Salem, Hytham S.
    Sodhi, Nipun
    Ehiorobo, Joseph O.
    Mont, Michael A.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 37
  • [23] Unicompartmental knee arthroplasty versus high tibial osteotomy for medial unicompartmental knee osteoarthritis
    Mueller, P. E.
    Pietschmann, M. F.
    ARTHROSKOPIE, 2009, 22 (03) : 199 - 204
  • [24] Robotic-assisted unicompartmental knee arthroplasty: a review
    Pei Liu
    Fei-fan Lu
    Guo-jie Liu
    Xiao-hong Mu
    Yong-qiang Sun
    Qi-dong Zhang
    Wei-guo Wang
    Wan-shou Guo
    Arthroplasty, 3
  • [25] Robotic-assisted unicompartmental knee arthroplasty: a review
    Liu, Pei
    Lu, Fei-fan
    Liu, Guo-jie
    Mu, Xiao-hong
    Sun, Yong-qiang
    Zhang, Qi-dong
    Wang, Wei-guo
    Guo, Wan-shou
    ARTHROPLASTY, 2021, 3 (01)
  • [26] UNICOMPARTMENTAL ARTHROPLASTY OF THE KNEE - CADAVER STUDY OF TIBIAL COMPONENT PLACEMENT
    MOLLER, JT
    WEETH, RE
    KELLER, JO
    ACTA ORTHOPAEDICA SCANDINAVICA, 1985, 56 (02): : 115 - 119
  • [27] DEFORMATION AND LOOSENING OF THE TIBIAL COMPONENT IN KNEE ARTHROPLASTY WITH UNICOMPARTMENTAL ENDOPROSTHESES
    KNUTSON, K
    JONSSON, G
    ANDERSEN, JL
    LARUSDOTTIR, H
    LIDGREN, L
    ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (06): : 667 - 673
  • [28] Robotic arm-assisted versus manual unicompartmental knee arthroplasty A SYSTEMATIC REVIEW AND META-ANALYSIS OF THE MAKO ROBOTIC SYSTEM
    Zhang, J.
    Ng, N.
    Scott, C. E. H.
    Blyth, M. J. G.
    Haddad, F. S.
    Macpherson, G. J.
    Patton, J. T.
    Clement, N. D.
    BONE & JOINT JOURNAL, 2022, 104B (05): : 541 - 548
  • [29] Comparison of robotic-assisted versus conventional unicompartmental knee arthroplasty for the treatment of single compartment knee osteoarthritis: A meta-analysis
    Zhang, Pei
    Xu, Keteng
    Zhang, Jiale
    Chen, Pengtao
    Fang, Yongchao
    Wang, Jingcheng
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2021, 17 (01): : 1 - 11
  • [30] Minimally invasive versus conventional unicompartmental knee arthroplasty
    Thomas J. Heyse
    Turgay Efe
    Stefan Rumpf
    Markus D. Schofer
    Susanne Fuchs-Winkelmann
    Jan Schmitt
    Carsten Hauk
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1287 - 1290