Quality assurance and system stability of a clinical MRI-guided focused ultrasound system: Four-year experience

被引:33
|
作者
McDannold, Nathan [1 ]
Hynynen, Kullervo [1 ]
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
magnetic resonance; focused ultrasound; water proton chemical shift; temperature mapping;
D O I
10.1118/1.2352853
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To retrospectively evaluate the four-year experience of a quality assurance method for a MRI-guided focused ultrasound system that uses temperature maps acquired during heating in an ultrasound/MRI phantom. This quality assurance method was performed before 148 clinical uterine fibroid thermal ablation treatments. The stability of the peak temperature rise, the targeting accuracy, the shape of the heated zone, and the noise level in the imaging was evaluated. The peak temperature rise was mostly stable for the first three years. An increase in heating was observed when the system was replaced after year three. Detection of this increase was taken into account in the subsequent clinical treatments. A small secondary hotspot was detected by the temperature maps and was seen to be resolved after system calibration. The average standard deviation in unheated regions of the phantom in the temperature maps was 0.5 +/- 0.2 degrees C; it was less than 1 degrees C in all but one procedure. The average initial targeting error was 2.8 +/- 1.8 and 2.8 +/- 2.1 mm in two radial directions and 7.7 +/- 2.9 mm along the ultrasound beam direction. The width of the heating profile was consistent over the four years. This simple method to evaluate the performance appeared to be sensitive to small changes in system performance, which was adequately stable over a four-year time period. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4307 / 4313
页数:7
相关论文
共 50 条
  • [21] MRI guided focused ultrasound robotic system for animal experiments
    Yiannakou, Marinos
    Menikou, Georgios
    Yiallouras, Christos
    Ioannides, Cleanthis
    Damianou, Christakis
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2017, 13 (04):
  • [22] Simple, inexpensive, and ergonomic phantom for quality assurance control of MRI guided Focused Ultrasound systems
    Anastasia Antoniou
    Christakis Damianou
    Journal of Ultrasound, 2023, 26 : 401 - 408
  • [23] Simple, inexpensive, and ergonomic phantom for quality assurance control of MRI guided Focused Ultrasound systems
    Antoniou, Anastasia
    Damianou, Christakis
    JOURNAL OF ULTRASOUND, 2023, 26 (02) : 401 - 408
  • [24] The development of the MRI linac system for online MRI-guided radiotherapy: a clinical update
    Lagendijk, J. J. W.
    van Vulpen, M.
    Raaymakers, B. W.
    JOURNAL OF INTERNAL MEDICINE, 2016, 280 (02) : 203 - 208
  • [25] MRI guided focused ultrasound robotic system for the treatment of gynaecological tumors
    Epaminonda, Eva
    Drakos, Theoharis
    Kalogirou, Christina
    Theodoulou, Margarita
    Yiallouras, Christos
    Damianou, Christakis
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2016, 12 (01): : 46 - 52
  • [26] MRI-guided percutaneous sclerotherapy of venous malformations: initial clinical experience using a 3T MRI system
    O'Mara, Daniel M.
    Berges, Alexandra J.
    Fritz, Jan
    Weiss, Clifford R.
    CLINICAL IMAGING, 2020, 65 (65) : 8 - 14
  • [27] Volumetric MRI-guided, high-intensity focused ultrasound ablation of uterine leiomyomas: ASEAN preliminary experience
    Keserci, Bilgin
    Nguyen Minh Duc
    Nadarajan, Chandran
    Huynh Quang Huy
    Saizan, Aishah
    Ahmed, Wan Aireene Wan
    Osman, Khalid
    Abdullah, Mohd Shafie
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2020, 26 (03) : 207 - 215
  • [28] One Year Quality Assurance Experience of the First RefleXion System
    Han, B.
    Shi, M.
    Cui, S.
    Chuang, C.
    Kovalchuk, N.
    Xing, L.
    Surucu, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E936 - E936
  • [29] Distortion-Free Diffusion MRI Using an MRI-Guided Radiation Therapy System: Sequence Validation and Preliminary Clinical Experience
    Gao, Y.
    Han, F.
    Zhou, Z.
    Cao, M.
    Kaprealian, T. B.
    Kamrava, M.
    Wang, C.
    Neylon, J.
    Low, D.
    Yang, Y.
    Hu, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : S124 - S124
  • [30] A system for MRI-guided thermal therapy of prostate disease with transurethral ultrasound heating applicators
    Chopra, R
    Choy, V
    Baker, S
    Tang, K
    Boyes, A
    Bronskill, M
    MEDICAL PHYSICS, 2005, 32 (07) : 2422 - 2422