Quality assurance and system stability of a clinical MRI-guided focused ultrasound system: Four-year experience

被引:33
|
作者
McDannold, Nathan [1 ]
Hynynen, Kullervo [1 ]
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
magnetic resonance; focused ultrasound; water proton chemical shift; temperature mapping;
D O I
10.1118/1.2352853
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To retrospectively evaluate the four-year experience of a quality assurance method for a MRI-guided focused ultrasound system that uses temperature maps acquired during heating in an ultrasound/MRI phantom. This quality assurance method was performed before 148 clinical uterine fibroid thermal ablation treatments. The stability of the peak temperature rise, the targeting accuracy, the shape of the heated zone, and the noise level in the imaging was evaluated. The peak temperature rise was mostly stable for the first three years. An increase in heating was observed when the system was replaced after year three. Detection of this increase was taken into account in the subsequent clinical treatments. A small secondary hotspot was detected by the temperature maps and was seen to be resolved after system calibration. The average standard deviation in unheated regions of the phantom in the temperature maps was 0.5 +/- 0.2 degrees C; it was less than 1 degrees C in all but one procedure. The average initial targeting error was 2.8 +/- 1.8 and 2.8 +/- 2.1 mm in two radial directions and 7.7 +/- 2.9 mm along the ultrasound beam direction. The width of the heating profile was consistent over the four years. This simple method to evaluate the performance appeared to be sensitive to small changes in system performance, which was adequately stable over a four-year time period. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4307 / 4313
页数:7
相关论文
共 50 条
  • [1] Quality assurance and system stability of a clinical MRI-guided focused ultrasound system: Three-year experience
    McDannold, Nathan
    Hynynen, Kullervo
    THERAPEUTIC ULTRASOUND, 2006, 829 : 652 - +
  • [2] The targeting accuracy of a preclinical MRI-guided focused ultrasound system
    Ellens, N. P. K.
    Kobelevskiy, I.
    Chau, A.
    Waspe, A. C.
    Staruch, R. M.
    Chopra, R.
    Hynynen, K.
    MEDICAL PHYSICS, 2015, 42 (01) : 430 - 439
  • [3] A Robotic Platform to Navigate MRI-guided Focused Ultrasound System
    Dai, Jing
    He, Zhuoliang
    Fang, Ge
    Wang, Xiaomei
    Li, Yingqi
    Cheung, Chim-Lee
    Liang, Liyuan
    Iordachita, Iulian
    Chang, Hing-Chiu
    Kwok, Ka-Wai
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2021, 6 (03): : 5137 - 5144
  • [4] Initial Quality Assurance Experience of the First Clinical Gantry-Mounted Proton Therapy System - A Four-Year Experience
    Liu, B.
    Carter, J.
    Qing, K.
    Nie, K.
    Wang, X.
    Cui, T.
    Zhang, M.
    Zou, J.
    Davis, R.
    Parikh, R.
    Yue, N.
    Zhang, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E249 - E249
  • [5] Positioning device for MRI-guided high intensity focused ultrasound system
    Damianou, Christakis
    Ioannides, Kleanthis
    Milonas, Nicos
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 2 (06) : 335 - 345
  • [6] MRI-guided focused ultrasound robotic system for the treatment of bone cancer
    Menikou, Georgios
    Yiallouras, Christos
    Yiannakou, Marinos
    Damianou, Christakis
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2017, 13 (01):
  • [7] Positioning device for MRI-guided high intensity focused ultrasound system
    Christakis Damianou
    Kleanthis Ioannides
    Nicos Milonas
    International Journal of Computer Assisted Radiology and Surgery, 2008, 2 : 335 - 345
  • [8] FOUR-YEAR EXPERIENCE WITH A CLINICAL ULTRASOUND QUALITY CONTROL PROGRAM
    Hangiandreou, Nicholas J.
    Stekel, Scott F.
    Tradup, Donald J.
    Gorny, Krzysztof R.
    King, Deirdre M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (08): : 1350 - 1357
  • [9] First clinical experience with a dedicated MRI-guided high-intensity focused ultrasound system for breast cancer ablation
    Laura G. Merckel
    Floor M. Knuttel
    Roel Deckers
    Thijs van Dalen
    Gerald Schubert
    Nicky H. G. M. Peters
    Teun Weits
    Paul J. van Diest
    Willem P. Th. M. Mali
    Paul H. H. B. Vaessen
    Joost M. H. H. van Gorp
    Chrit T. W. Moonen
    Lambertus W. Bartels
    Maurice A. A. J. van den Bosch
    European Radiology, 2016, 26 : 4037 - 4046
  • [10] First clinical experience with a dedicated MRI-guided high-intensity focused ultrasound system for breast cancer ablation
    Merckel, Laura G.
    Knuttel, Floor M.
    Deckers, Roel
    van Dalen, Thijs
    Schubert, Gerald
    Peters, Nicky H. G. M.
    Weits, Teun
    van Diest, Paul J.
    Mali, Willem P. Th. M.
    Vaessen, Paul H. H. B.
    van Gorp, Joost M. H. H.
    Moonen, Chrit T. W.
    Bartels, Lambertus W.
    van den Bosch, Maurice A. A. J.
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 4037 - 4046