The optimized match method enhances the energy efficiency ratio (EER) of room air-conditioner

被引:0
|
作者
Wang Zhiyuan [1 ]
Hetao [1 ]
Xu Zhiliang [1 ]
Luohao [1 ]
Dang Hongchang [2 ]
机构
[1] Henan Univ Sci & Technol, Coll Vehicle & Power, Luoyang, Peoples R China
[2] Anhui Ind Univ, Maanshan, Peoples R China
关键词
air-conditioner; System; Optimization; EER; HEAT-TRANSFER; CONDENSATION; TUBES;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, an experimental study was conducted on domestic air- conditioner refrigeration system to increase the system energy efficiency ratio (EER). First, different types of high efficiency compressors were tested and selected. Second, inner-grooved copper tubes which had fins with hydrophilic membrane, together with the indoor and outdoor helical fans were employed to improve the heat convection efficiency. Third, the relationship between capillary's optimum length and refrigerant charge quantity was confirmed experimentally. By these means, the system EER can reach up to 3.2, which meets the demands of National standards of China.
引用
收藏
页数:5
相关论文
共 50 条
  • [22] High energy efficiency desiccant assisted automobile air-conditioner and its temperature and humidity control system
    Nagaya, K
    Senbongi, T
    Li, Y
    Zheng, J
    Murakami, I
    APPLIED THERMAL ENGINEERING, 2006, 26 (14-15) : 1545 - 1551
  • [23] Renewable Energy Source Allocation of Air-Conditioner Using Fuzzy Logic
    Rao, M. Nageswara
    Ravindra, K.
    Chaitanya, V. S. N. K.
    PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING AND CONTROL (I2C2), 2017,
  • [24] Experimental Study of Energy-Saving Air-Conditioner with Hot Water
    CHEN Jian-bo
    CHEN Dan
    LU Ying(University of Shanghai for Science and Technology
    Shanghai
    China)
    湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 75 - 78
  • [25] Energy reduction of building air-conditioner with phase change material in Thailand
    Chaiyat, Nattaporn
    Kiatsiriroat, Tanongkiat
    CASE STUDIES IN THERMAL ENGINEERING, 2014, 4 : 175 - 186
  • [26] Experimental study of energy-saving air-conditioner with hot water
    Chen, Jian-Bo
    Chen, Dan
    Lu, Ying
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL.): : 75 - 78
  • [27] Experimental Study of Energy-Saving Air-Conditioner with Hot Water
    CHEN Jian-bo
    湖南大学学报(自然科学版), 2009, (S1) : 75 - 78
  • [28] Effect of the airflow rate of a ceiling type air-conditioner on ventilation effectiveness in a lecture room
    Noh, Kwang-Chul
    Han, Chang-Woo
    Oh, Myung-Do
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (02): : 180 - 188
  • [29] Detailed dynamic refrigerant migration characteristics in room air-conditioner with R290
    Liang Jierong
    Li Tingxun
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 108 - 116
  • [30] EASY INSTALLATION OF TOSHIBA ROOM AIR-CONDITIONER, PERSONALTM RAC-141ET
    SANO, H
    INOUE, O
    TOSHIBA REVIEW, 1976, (106): : 38 - 41