Experimental Study of Energy-Saving Air-Conditioner with Hot Water

被引:0
|
作者
CHEN Jian-bo
CHEN Dan
LU Ying(University of Shanghai for Science and Technology
Shanghai
China)
机构
关键词
D O I
暂无
中图分类号
TU831 [空气调节];
学科分类号
080705 ;
摘要
Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in series in the system.This experiment of the energy-saving air-conditioner was carried out in the enthalpy-difference air-conditioner laboratory.The hot water temperature and the compressor's discharge and suction pressure were recorded in the working condition,where the ambient temperature was at 43 ℃,35 ℃,21 ℃,7 ℃,and 2 ℃ separately.The results showed that the system operated stably and reliably.This system can supply 240 L hot water at 50 ℃ in the whole year,and its coefficience of performance(COP)is much higher than the conventional air source heat pump system.Its energy conservation was proved by comparing the thermal efficiency with other sourece water heaters.
引用
收藏
页码:75 / 78
页数:4
相关论文
共 50 条
  • [1] Experimental study of energy-saving air-conditioner with hot water
    Chen, Jian-Bo
    Chen, Dan
    Lu, Ying
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL.): : 75 - 78
  • [3] The Spray Fan and Saving Water of the Textile Air-conditioner
    Xu, Hong
    Hui, Jing
    CHINA FUNCTIONAL MATERIALS TECHNOLOGY AND INDUSTRY FORUM, 2013, 320 : 753 - 756
  • [4] Experimental Research on Improvement of the Heat Pump Air-conditioner and Hot Water System
    Chen, Jianbo
    Li, Fen
    Min, Kuangwei
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 6199 - 6203
  • [5] Design and implementation of energy saving controller for air-conditioner in building
    Zhao, Liang
    Zhang, Jili
    Shen, Yue
    Wu, Wenyan
    Zhang, Jili, 2015, Science and Engineering Research Support Society (09): : 47 - 54
  • [6] The effect of air-conditioner operation modes on the energy-saving capacity of external wall insulation in residential buildings
    Deng, Qinli
    Liu, Daoru
    Zhou, Zeng
    Ma, Sha
    ENERGY EXPLORATION & EXPLOITATION, 2021, 39 (02) : 620 - 636
  • [7] Energy-Saving Occupant-Feedback Control Method Under Preferred Air-Conditioner Settings of Occupants
    Yano, Toru
    Sako, Miho
    IEEE ACCESS, 2024, 12 : 29126 - 29143
  • [8] Experimental research on the operational characteristics of household air-conditioner with domestic hot water supply
    Gao, Yanbing
    Huai, Lanlan
    Jin, Wen
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 677 - 682
  • [9] An Experimental Study on Water Harvesting from a Modified Window Air-Conditioner
    Dalai, Purnendu
    Nanda, Prasant
    Mund, Chinmaya
    Mishra, Debasmita
    Gupta, Abhijeet
    INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 : 253 - 260
  • [10] The Experimental Study of Thermodynamic Performance on R407C Air-conditioner Hot Water Combined Unit
    Hu, Hongsong
    Wang, Fang
    Yu, Jianzhong
    Hao, Wu
    MATERIALS, MECHATRONICS AND AUTOMATION, PTS 1-3, 2011, 467-469 : 549 - 553