Experimental Study of Energy-Saving Air-Conditioner with Hot Water

被引:0
|
作者
CHEN Jian-bo
CHEN Dan
LU Ying(University of Shanghai for Science and Technology
Shanghai
China)
机构
关键词
D O I
暂无
中图分类号
TU831 [空气调节];
学科分类号
080705 ;
摘要
Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in series in the system.This experiment of the energy-saving air-conditioner was carried out in the enthalpy-difference air-conditioner laboratory.The hot water temperature and the compressor's discharge and suction pressure were recorded in the working condition,where the ambient temperature was at 43 ℃,35 ℃,21 ℃,7 ℃,and 2 ℃ separately.The results showed that the system operated stably and reliably.This system can supply 240 L hot water at 50 ℃ in the whole year,and its coefficience of performance(COP)is much higher than the conventional air source heat pump system.Its energy conservation was proved by comparing the thermal efficiency with other sourece water heaters.
引用
收藏
页码:75 / 78
页数:4
相关论文
共 50 条
  • [41] Experimental study on the effect of air outflow parameters of wall mounted air-conditioner on the indoor thermal environment
    Lai, Y. H.
    Zhang, J. G.
    Guo, L.
    Lin, Charlie
    Lu, M. X.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 492 - 498
  • [42] Experimental study on energy performance of a split air-conditioner by using variable thickness evaporative cooling pads coupled to the condenser
    Martinez, P.
    Ruiz, J.
    Cutillas, C. G.
    Martinez, P. J.
    Kaiser, A. S.
    Lucas, M.
    APPLIED THERMAL ENGINEERING, 2016, 105 : 1041 - 1050
  • [43] Experimental study on continuous running performance and energy consumption analysis of portable air-conditioner with variable condensate supply methods
    Kim, Dae Hyeok
    Lee, Jae Won
    Kang, Yong Tae
    ENERGY, 2023, 281
  • [44] Study on the energy saving and the performance of air conditioner with variable speed compressor
    Shao, SQ
    Shi, WX
    Li, XT
    Yan, QS
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 539 - 545
  • [45] Experimental investigations on the thermal characteristics of a multi-functional air-conditioner
    Qiu, Fuqiang
    Du, Juanli
    Xu, Taoping
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2023, 18 : 218 - 227
  • [46] Experimental investigations on the thermal characteristics of a multi-functional air-conditioner
    Qiu, Fuqiang
    Du, Juanli
    Xu, Taoping
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2023, 18 : 218 - 227
  • [47] SIMULATION OF THE CHILLED WATER SYSTEM OF GAS-FIRED AIR-CONDITIONER
    Lan, Li
    Zhang, Ling
    Lian, Zhiwei
    Liu, Zhongbing
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1857 - 1864
  • [48] Take an Energy-saving And Comfortable Hot Bath
    Zhou, Yibin
    PROCEEDINGS OF THE 2017 5TH INTERNATIONAL CONFERENCE ON FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY (FMSMT 2017), 2017, 130 : 657 - 660
  • [49] Experimental study of the effects of the cycle characteristics on the refrigerant-induced noise in system air-conditioner
    Weui Bong Jeong
    Hyung Suk Han
    Jin Yong Mo
    Jae Kwon Lee
    Journal of Mechanical Science and Technology, 2007, 21 : 1112 - 1119
  • [50] Renewable Energy Source Allocation of Air-Conditioner Using Fuzzy Logic
    Rao, M. Nageswara
    Ravindra, K.
    Chaitanya, V. S. N. K.
    PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING AND CONTROL (I2C2), 2017,