The present article reviews the most significant results obtained over the last five years on the use of HPLC to study mammalian MT polymorphism. Firstly, it has been shown that reverse phase HPLC with electrochemical (EC, coulometric) detection allowed us to follow the chemical evolution of a trithiolic hexapeptide intrinsic to the MT structure. The EC response is proportional to the number of free thiols, which permits the identification of the reduced and oxidised forms of the peptide which are well separated. This EC detection was then applied to MT characterisation. Four MTs from rabbit Liver and horse kidney were subjected to RP-HPLC (TFA/acetonitile) with on-line UV and EC detection. They were found to exhibit a different polymorphism. Actually, two types of peaks were observed, those equally detected by UV and by EC being attributed to original thiol containing sub-isoforms and those less hydrophobic, detected by UV but hardly at ail by EC, being attributed to oxidised forms containing disulphides instead of thiols, hence not detectable in our EC mode. The elutions were then carried out at various temperatures between 25 and 60 degrees C. This appears to have two main effects: small retention time decrease of all peaks with increasing temperature and large effect on peak 'detectability": when the temperature rises, a drastic alteration of the oxidised peaks is observed. As a result, between 20 and 40 degrees C all peaks are detected and resolved, while at 60 degrees C only those peaks assumed to be the original sub-isoforms, hence heat-stable, are present. Previous to that, separation of MT by size exclusion chromatography had shown that they were all partially dimerised (5 to 15% of molar rates of dimers). Although small, these levels of non-monomer MT are not negligible.
引用
收藏
页码:73 / 84
页数:12
相关论文
共 50 条
  • [21] Evaluation of Suwannee River NOM electrophoretic fractions by RP-HPLC with online absorbance and fluorescence detection
    Olga E. Trubetskaya
    Claire Richard
    Oleg A. Trubetskoj
    Environmental Science and Pollution Research, 2015, 22 : 9989 - 9998
  • [22] RP-HPLC method with electrochemical detection for the determination of metoclopramide in serum and its use in pharmacokinetic studies
    Lamparczyk, H
    Chmielewska, A
    Konieczna, L
    Plenis, A
    Zarzycki, PK
    BIOMEDICAL CHROMATOGRAPHY, 2001, 15 (08) : 513 - 517
  • [23] DETERMINATION OF NITRITE AS PENTAFLUOROBENZYL DERIVATIVE BY RP-HPLC AND UV DETECTION WITH AND WITHOUT ION-PAIR EXTRACTION
    TSIKAS, D
    FROLICH, JC
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 344 (06): : 256 - 260
  • [24] HPLC-RP separation with electrochemical detection of daminozide and 1,1-dimethylhydrazine
    Barek, J
    Teraso, A
    Mejstrik, V
    Moreira, JC
    Zima, J
    CHEMIA ANALITYCZNA, 2003, 48 (03): : 483 - 493
  • [25] A. simple method for the. simultaneous determination of guanine, xanthine and hypoxanthine by RP-HPLC with UV detection
    Majumder, Natasha
    Chowdhury, Chumki
    Jana, Tapan Kumar
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2015, 92 (09) : 1381 - 1385
  • [26] Study of mammalian metallothionein polymorphism by reverse phase HPLC with on-line diode array and electrochemical detection
    Bordin, G
    Cordeiro-Raposo, F
    Rodríguez, AR
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (07) : 999 - 1018
  • [27] Evaluation of the separation of steroids in combined forms by RP HPLC with UV-detection and gas chromatography
    Tsvetkova, D.
    Obreshkova, D.
    Ivanova, S.
    Hadjieva, B.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2017, 49 (02): : 377 - 383
  • [28] Use of a one-line fluorescence detection to characterize glutenin fraction in the separation techniques (SE-HPLC and RP-HPLC)
    Aussenac, T
    Carceller, JL
    WHEAT GLUTEN, 2000, (261): : 144 - 148
  • [29] Determination of florfenicol residues in broiler meat and liver samples using RP-HPLC with UV-visible detection
    Nasim, Asma
    Aslam, Bilal
    Javed, Ijaz
    Ali, Asghar
    Muhammad, Faqir
    Raza, Ahmad
    Sindhu, Zia-ud-Din
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2016, 96 (04) : 1284 - 1288
  • [30] Simultaneous determination of adenosine triphosphate and its metabolites in human whole blood by RP-HPLC and UV-detection
    Coolen, Erik J. C. M.
    Arts, Ilaj C. W.
    Swennen, Els L. R.
    Bast, Aalt
    Stuart, Martien A. Cohen
    Dagnelie, Pieter C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 864 (1-2): : 43 - 51