A 256 x 256 2-D Array Transducer with Row-Column Addressing for 3-D Rectilinear Imaging

被引:90
|
作者
Seo, Chi Hyung [1 ]
Yen, Jesse T. [2 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
关键词
3-DIMENSIONAL ULTRASOUND; BREAST;
D O I
10.1109/TUFFC.2009.1107
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We present simulation and experimental results from a 5-MHz, 256 x 256 2-D (65536 elements, 38.4 x 38.4 mm) 2-D array transducer with row-column addressing. The main benefits of this design are a reduced number of interconnects, a modified transmit/receive switching scheme with a simple diode circuit, and an ability to perform volumetric imaging of targets near the transducer with transmit beamforming in azimuth and receive beamforming in elevation. The final dimensions of the transducer were 38.4 mm x 38.4 rum x 300 mu m. After a row-column transducer was prototyped, the series resonance impedance was 104 Omega at 5.4 MHz. The measured -6 dB fractional bandwidth was 53% with a center frequency of 5.3 MHz. The SNR at the transmit focus was measured to be 30 dB. At 5 MHz, the average nearest neighbor crosstalk was -25 dB. In this paper, we present 3-D images of both 5 pairs of nylon wires embedded in a clear gelatin phantom and an 8 mm diameter cylindrical anechoic cyst phantom acquired from a 256 x 256 2-D array transducer made from a 1-3 composite. We display the azimuth and elevation B-scans as well as the C-scan for each image. The cross-section of the wires is visible in the azimuth B-scan, and the long axes can be seen in the elevation B-scan and C-scans. The pair of wires with 1-mm axial separation is discernible in the elevational B-scan. When a single wire from the wire target phantom was used, the measured lateral beamwidth was 0.68 mm and 0.70 mm at 30 mm depth in transmit beamforming and receive beamforming, respectively, compared with the simulated beamwidth of 0.55 mm. The cross-section of the cyst is visible in the azimuth B-scan whereas the long axes can be seen as a rectangle in the elevation B-scan and C-scans.
引用
收藏
页码:837 / 847
页数:11
相关论文
共 50 条
  • [41] Fourier-Based Fast 3-D Ultrasound Imaging Using Row-Column-Addressed 2-D Arrays
    Lin, Shang-Ching
    Li, Pai-Chi
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (01) : 85 - 101
  • [42] Strain Imaging Using a Rectilinear 2-D Array: Preliminary Results
    Awad, Samer I.
    Lye, Yan Lin
    Yen, Jesse T.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 1270 - 1273
  • [43] In vivo 3D Super-Resolution Ultrasound Imaging of a Rat Kidney using a Row-Column Array
    Taghavi, Iman
    Schou, Mikkel
    Panduro, Nathalie Sarup
    Andersen, Sofie Bech
    Tomov, Borislav G.
    Sorensen, Charlotte Mehlin
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [44] 3D Volumetric Tensor Velocity Imaging with Low Computational Complexity Using a Row-Column Addressed Array
    Chetverikova, Kseniya
    Jensen, Jorgen Arendt
    Traberg, Marie Sand
    Stuart, Matthias Bo
    APPLIED SCIENCES-BASEL, 2021, 11 (12):
  • [45] Sparse 2-D Arrays for 3-D phased array imaging - Design methods
    Austeng, A
    Holm, S
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1073 - 1086
  • [46] ADS-Based Array Design for 2-D and 3-D Ultrasound Imaging
    Oliveri, Giacomo
    Massa, Andrea
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (07) : 1568 - 1582
  • [47] 3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array
    Harput, Sevan
    Tortoli, Piero
    Eckersley, Robert J.
    Dunsby, Chris
    Tang, Meng-Xing
    Christensen-Jeffries, Kirsten
    Ramalli, Alessandro
    Brown, Jemma
    Zhu, Jiaqi
    Zhang, Ge
    Leow, Chee Hau
    Toulemonde, Matthieu
    Boni, Enrico
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (02) : 269 - 277
  • [48] Sparse 2-D arrays for 3-D phased array imaging - Experimental validation
    Austeng, A
    Holm, S
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1087 - 1093
  • [49] Minimally Redundant 2-D Array Designs for 3-D Medical Ultrasound Imaging
    Karaman, Mustafa
    Wygant, Ira O.
    Oralkan, Oemer
    Khuri-Yakub, Butrus T.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (07) : 1051 - 1061
  • [50] Dual-layer transducer array for 3-d imaging
    Jeong, Jong Seob
    Seo, Chi Hyung
    Yen, Jesse T.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 2371 - 2374