THE EFFECT OF ASPHERICITY OF ACETABULAR BEARING SURFACE ON CONTACT MECHANICS OF UHMWPE TOTAL HIP IMPLANTS BY FINITE ELEMENT ANALYSIS

被引:1
|
作者
Zhang, Xuan [1 ]
Wang, Ling [1 ]
Peng, Xifeng [1 ]
Li, Dichen [1 ]
He, Jiankang [1 ]
Liu, Yaxiong [1 ]
Lian, Qin [1 ]
Jin, Zhongmin [1 ,2 ]
Liu, Chaozong [3 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, Xian 710049, Peoples R China
[2] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
[3] UCL, Royal Natl Orthopaed Hosp, John Scales Ctr Biomed Engn, London HA7 4LP, England
基金
中国国家自然科学基金;
关键词
Total hip arthroplasty; asphericity; contact mechanics; finite element analysis; edge loading; MOLECULAR-WEIGHT POLYETHYLENE; METAL-ON-METAL; WEAR DEBRIS; REPLACEMENTS; ARTHROPLASTY; CUPS; PROSTHESES; RATES;
D O I
10.1142/S0219519417500117
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Asphericity and out-of-roundness are generally used to evaluate the manufacturing quality of ultra-high molecular weight polyethylene (UHMWPE) cup inner surfaces, which can potentially affect initial clinical wear and contribute to osteolysis of total hip arthroplasty. This study measured the location and magnitude of asphericity and the out-of-roundness value for four UHMWPE cups in a single set, and then investigated the effects of the asphericity on the contact mechanics of UHMWPE cups. A co-ordinate measuring machine (CMM) was used for the surface measurement and finite element analysis (FEA) was adopted for contact mechanics study. The results demonstrated that the asphericity varied between cups with the maximum value as 0.088 +/- 0.004 mm. Although such a value met the ISO specification, large difference of volume appeared for the asphericity above 0.060 mm. Actual surface profile accounting for the asphericity was found to affect the value of contact pressure and contact area by around 12%. The inferior asphericity resulted in a nonsmoothly distributed contact pressure, which had a negative effect on the contact mechanics of UHMWPE cups and the edge loading was predicted to occur for the sample with a large asphericity. In conclusion, the asphericity of UHMWPE cup could affect the contact mechanics of the articular bearings and may subsequently contribute to initial wear during bedding-in phase.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Effect of Negative Poisson's Ratios of Auxetic UHMWPE on the Contact Mechanics in Artificial Hip Joint Replacement
    Xie, Fang
    Liu, Zuomin
    NEW MATERIALS, APPLICATIONS AND PROCESSES, PTS 1-3, 2012, 399-401 : 1559 - +
  • [42] Finite element analysis of the effect of surface roughness on nanometer-scale contact
    Higashino, Tasuku
    Suga, Tadatomo
    6TH INTERNATIONAL IEEE CONFERENCE ON POLYMERS AND ADHESIVES IN MICROELECTRONICS AND PHOTONICS, PROCEEDINGS 2007, 2007, : 209 - +
  • [43] EFFECT OF ROUGH SURFACE ASYMMETRY ON CONTACT ENERGY LOSS IN HIP IMPLANTS
    Hodaei, Mohammad
    Farhang, Kambiz
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (01)
  • [44] Effect of inclination and anteversion angles on kinematics and contact mechanics of dual mobility hip implants
    Gao, Yongchang
    Chen, Zhenxian
    Zhang, Zhifeng
    Chen, Shibin
    Jin, Zhongmin
    CLINICAL BIOMECHANICS, 2018, 57 : 48 - 55
  • [45] Effect of Average Conformity on Contact Stresses in Total Knee Replacement: Finite Element Analysis
    Usman
    Huang, Shyh Chour
    2017 INTERNATIONAL CONFERENCE ON MECHANICAL, AERONAUTICAL AND AUTOMOTIVE ENGINEERING (ICMAA 2017), 2017, 108
  • [46] Effect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
    Darwich, Ayham
    Nazha, Hasan
    Daoud, Monzer
    JOURNAL OF APPLIED AND COMPUTATIONAL MECHANICS, 2020, 6 (02): : 284 - 295
  • [47] Analysis of contact mechanics in McKee-Farrar metal-on-metal hip implants
    Yew, A
    Jagatia, M
    Ensaff, H
    Jin, ZM
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2003, 217 (H5) : 333 - 340
  • [48] The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups - finite element simulations and experimental tests
    Korhonen, Rami K.
    Koistinen, Arto
    Konttinen, Yrjo T.
    Santavirta, Seppo S.
    Lappalainen, Reijo
    BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)
  • [49] The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups – finite element simulations and experimental tests
    Rami K Korhonen
    Arto Koistinen
    Yrjö T Konttinen
    Seppo S Santavirta
    Reijo Lappalainen
    BioMedical Engineering OnLine, 4
  • [50] Effect of coronal plane acetabular correction on joint contact pressure in Periacetabular osteotomy: a finite-element analysis
    Kitamura, Kenji
    Fujii, Masanori
    Iwamoto, Miho
    Ikemura, Satoshi
    Hamai, Satoshi
    Motomura, Goro
    Nakashima, Yasuharu
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)