Endovascular repair of abdominal aortic aneurysm with the ancure endograft: CT follow-up of perigraft flow and aneurysm size at 6 months

被引:22
|
作者
Franco, TJ
Zajko, AB
Federle, MP
Makaroun, MS
机构
[1] Univ Pittsburgh, Med Ctr, Div Intervent Radiol, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Med Ctr, Div Vasc Surg, Pittsburgh, PA 15213 USA
关键词
aneurysm; aortic; CT; therapy; stents and prostheses;
D O I
10.1016/S1051-0443(07)61374-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: Perigraft flow-flow outside the graft lumen but contained within the abdominal aortic aneurysm (AAA)-is a potential complication after endovascular repair of AAA. Such flow may permit AAA growth and rupture. The purpose of this study is to evaluate with computed tomography (CT) the rate of spontaneous closure of perigraft flow and the effect of persistent flow on AAA diameter. MATERIALS AND METHODS: During a 30-month period, the authors evaluated all CT scans in 50 patients who underwent AAA repair using the Ancure endograft system CT was performed at discharge, 6, 12, and 24 months, and at 3 months if there was perigraft now at discharge. Scans were reviewed for the presence, size, and location of perigraft flow, and measurement of AAA diameter. Transcatheter embolization was performed on those patients with persistent leak at 6 months. RESULTS: Sixteen (32%) of 50 patients demonstrated perigraft flow on CT performed within 72 hours of placement. Resolution of perigraft flow by 6 months was found in nine (56%) of the 16 patients, in whom AAA size had decreased in five, had increased in none, and was unchanged in four. Seven patients had persistent leaks at g-month CT; AAA size had decreased in one, had increased in one, and was unchanged in five. In 34 patients without leaks, AAA size had decreased in nine, had increased in one, and was unchanged on 24. There was no statistically significant difference for the relationship between resolution or persistence of perigraft flow and subsequent course of AAA diameter (P = .16). CONCLUSIONS: Although perigraft flow is frequently seen (32%) early after repair of AAA with the Ancure system, spontaneous resolution by 6 months occurs in 56% of cases. AAA size decreased in a larger percentage of patients in whom perigraft leak was absent or resolved by 6 months compared with those in whom perigraft leak persisted at 6 months.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 50 条
  • [32] Diagnostic value of color duplex ultrasonography in the follow-up of endovascular repair of abdominal aortic aneurysm
    Sun, Zhonghua
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (05) : 759 - 764
  • [33] Endovascular Repair of Abdominal Aortic Aneurysm: Follow-up with Noninvasive Vascular Elastography in a Canine Model
    Salloum, Eli
    Bertrand-Grenier, Antony
    Lerouge, Sophie
    Kauffman, Claude
    Heon, Helene
    Therasse, Eric
    Salazkin, Igor
    Cardinal, Marie-Helene Roy
    Cloutier, Guy
    Soulez, Gilles
    RADIOLOGY, 2016, 279 (02) : 410 - 419
  • [34] Endoleaks during follow-up after endovascular repair of abdominal aortic aneurysm - Are they all dangerous?
    Buth, J
    Harris, PL
    Van Marrewijk, C
    Fransen, G
    JOURNAL OF CARDIOVASCULAR SURGERY, 2003, 44 (04): : 559 - 566
  • [35] Extended Follow-Up of Open vs Endovascular Repair for Abdominal Aortic Aneurysm: the OVER Trial
    Freischlag, Julie A.
    Kyriakides, Tassos C.
    Stroupe, Kevin T.
    Padberg, Frank T., Jr.
    Matsumura, Jon S.
    Huo, Zhiping
    Johnson, Gary R.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2018, 227 (04) : E1 - E1
  • [36] A Simple Booklet for Patient Follow-Up After Endovascular Abdominal Aortic Aneurysm Repair Procedures
    Antoniadis, Pavlos N.
    Kyriakidis, Konstantinos D.
    Paraskevas, Kosmas I.
    ANGIOLOGY, 2012, 63 (08) : 634 - 637
  • [37] Follow-up imaging experience with endovascular abdominal aortic aneurysm stents
    Khan, AM
    Jafri, SZ
    Khan, S
    Salem, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 125 - 125
  • [38] What Is the Optimal Abdominal Aortic Aneurysm Sac Measurement on CT Images during Follow-up after Endovascular Repair?
    Boos, Johannes
    Brook, Olga R.
    Fang, Jieming
    Temin, Nathaniel
    Brook, Alexander
    Raptopoulos, Vasillios
    RADIOLOGY, 2017, 285 (03) : 1032 - 1041
  • [39] The influence of gender and aortic aneurysm size on eligibility for endovascular abdominal aortic aneurysm repair
    Sweet, Matthew P.
    Fillinger, Mark F.
    Morrison, Tina M.
    Abel, Dorothy
    JOURNAL OF VASCULAR SURGERY, 2011, 54 (04) : 931 - 937
  • [40] A multidetector tomography protocol for follow-up of endovascular aortic aneurysm repair
    Bastos, Roberto Moraes
    Razuk Filho, Alvaro
    Blasbalg, Roberto
    Caffaro, Roberto Augusto
    Karakhanian, Walter Khegan
    Rocha, Antonio Jose
    CLINICS, 2011, 66 (12) : 2025 - 2029