Endovascular repair of abdominal aortic aneurysm with the ancure endograft: CT follow-up of perigraft flow and aneurysm size at 6 months

被引:22
|
作者
Franco, TJ
Zajko, AB
Federle, MP
Makaroun, MS
机构
[1] Univ Pittsburgh, Med Ctr, Div Intervent Radiol, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Med Ctr, Div Vasc Surg, Pittsburgh, PA 15213 USA
关键词
aneurysm; aortic; CT; therapy; stents and prostheses;
D O I
10.1016/S1051-0443(07)61374-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: Perigraft flow-flow outside the graft lumen but contained within the abdominal aortic aneurysm (AAA)-is a potential complication after endovascular repair of AAA. Such flow may permit AAA growth and rupture. The purpose of this study is to evaluate with computed tomography (CT) the rate of spontaneous closure of perigraft flow and the effect of persistent flow on AAA diameter. MATERIALS AND METHODS: During a 30-month period, the authors evaluated all CT scans in 50 patients who underwent AAA repair using the Ancure endograft system CT was performed at discharge, 6, 12, and 24 months, and at 3 months if there was perigraft now at discharge. Scans were reviewed for the presence, size, and location of perigraft flow, and measurement of AAA diameter. Transcatheter embolization was performed on those patients with persistent leak at 6 months. RESULTS: Sixteen (32%) of 50 patients demonstrated perigraft flow on CT performed within 72 hours of placement. Resolution of perigraft flow by 6 months was found in nine (56%) of the 16 patients, in whom AAA size had decreased in five, had increased in none, and was unchanged in four. Seven patients had persistent leaks at g-month CT; AAA size had decreased in one, had increased in one, and was unchanged in five. In 34 patients without leaks, AAA size had decreased in nine, had increased in one, and was unchanged on 24. There was no statistically significant difference for the relationship between resolution or persistence of perigraft flow and subsequent course of AAA diameter (P = .16). CONCLUSIONS: Although perigraft flow is frequently seen (32%) early after repair of AAA with the Ancure system, spontaneous resolution by 6 months occurs in 56% of cases. AAA size decreased in a larger percentage of patients in whom perigraft leak was absent or resolved by 6 months compared with those in whom perigraft leak persisted at 6 months.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 50 条
  • [21] Inflammatory Abdominal Aortic Aneurysm Endovascular Repair into the Long-Term Follow-Up
    Coppi, Gioacchino
    Rametta, Francesco
    Aiello, Stefano
    Saitta, Giuseppe
    Gennai, Stefano
    Silingardi, Roberto
    ANNALS OF VASCULAR SURGERY, 2010, 24 (08) : 1053 - 1059
  • [22] Treatment of abdominal aortic aneurysm (AAA) with the Guidant-Ancure Endograft: 3-8-year follow-up at a single center
    Gomes, AS
    Moore, WS
    Quinones-Baldrich, WJ
    Vescera, CL
    Monteleone, P
    RADIOLOGY, 2002, 225 : 494 - 494
  • [23] Endovascular Technique Versus Conventional Replacement for Abdominal Aortic Aneurysm Up to 24 Months of Follow-Up
    De Luca, Ignacio
    Castelli, Mariano
    Pfund, Guillermo
    Alamo, Alejandro
    Auza, Delfina
    Zaefferer, Patricio
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (05) : E143 - E144
  • [24] Results of the endovascular abdominal aortic aneurysm repair using the Anaconda aortic endograft
    Freyrie, Antonio
    Gallitto, Enrico
    Gargiulo, Mauro
    Faggioli, Gianluca
    Massoni, Claudio Bianchini
    Mascoli, Chiara
    Pini, Rodolfo
    Stella, Andrea
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (05) : 1132 - 1139
  • [25] Endovascular Relining of a Perigraft Hygroma After Open Abdominal Aortic Aneurysm Repair
    Landis, Ryan
    Amiri, Farzad
    Denning, David
    Constantinou, Constantinou
    AMERICAN SURGEON, 2018, 84 (02) : E87 - E88
  • [26] Endograft Conformability and Aortoiliac Tortuosity in Endovascular Abdominal Aortic Aneurysm Repair
    Lee, Kevin
    Leci, Erik
    Forbes, Thomas
    Dubois, Luc
    DeRose, Guy
    Power, Adam
    JOURNAL OF ENDOVASCULAR THERAPY, 2014, 21 (05) : 728 - 734
  • [27] Follow-up of abdominal aortic aneurysm after endovascular aortic repair: Comparison of volumetric and diametric measurement
    Hahne, J. D.
    Arndt, C.
    Herrmann, J.
    Schoennagel, B.
    Adam, G.
    Habermann, C. R.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (06) : 1187 - 1191
  • [28] Abdominal aortic aneurysm repair: long-term follow-up of endovascular versus open repair
    Piffaretti, Gabriele
    Mariscalco, Giovanni
    Riva, Francesca
    Fontana, Federico
    Carrafiello, Gianpaolo
    Castelli, Patrizio
    ARCHIVES OF MEDICAL SCIENCE, 2014, 10 (02) : 273 - 282
  • [29] Computed tomography and ultrasound in follow-up of patients after endovascular repair of abdominal aortic aneurysm
    Elkouri, S
    Panneton, JM
    Andrews, JC
    Lewis, BD
    McKusick, MA
    Noel, AA
    Rowland, CM
    Bower, TC
    Cherry, KJ
    Gloviczki, P
    ANNALS OF VASCULAR SURGERY, 2004, 18 (03) : 271 - 279
  • [30] Transcatheter, endovascular repair of abdominal aortic aneurysm: Feasibility, noninvasive diagnosis, problems, and follow-up
    Kronzon, I
    Varkey, M
    Tunick, PA
    Riles, T
    Rosen, R
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1999, 16 (06): : 617 - 623