Review of the Mechanical Behavior of Different Implant-Abutment Connections

被引:54
|
作者
Vinhas, Ana Sofia [1 ]
Aroso, Carlos [2 ]
Salazar, Filomena [1 ]
Lopez-Jarana, Paula [1 ]
Rios-Santos, Jose Vicente [3 ]
Herrero-Climent, Mariano [4 ]
机构
[1] Inst Univ Ciencias Saude, Dept Periodontol, P-4585116 Gandra, Portugal
[2] Inst Univ Ciencias Saude, Dept Prosthodont, P-4585116 Gandra, Portugal
[3] Univ Seville, Sch Dent, Dept Periodontol, C Avicena S-N, Seville 41009, Spain
[4] Porto Dent Inst, P-4150518 Porto, Portugal
关键词
implant– abutment connection; preload; tightening torque; cyclic loading; misfit; microleakage; IN-VITRO EVALUATION; EXTERNAL-CONNECTION; TORQUE MAINTENANCE; BACTERIAL LEAKAGE; REMOVAL TORQUE; PRELOAD; HEXAGON; DESIGN; INTERFACE; FATIGUE;
D O I
10.3390/ijerph17228685
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Introduction: Different implant-abutment connections have been developed to reduce mechanical and biological failure. The most frequent complications are loss of preload, screw loosening, abutment or implant fracture, deformations at the different interfaces, and bacterial microleakage. Aim: To review the evidence indicating whether the implant-abutment connection type is significant regarding the following issues: (1) maintenance of the preload in static and dynamic in vitro studies; (2) assessment of possible deformations at the implant-abutment interfaces, after repeated application of the tightening torque; (3) evaluation of the sealing capability of different implant connections against microleakage. Materials and Methods: In June 2020, an electronic literature search was performed in Medline, EBSCO host, and PubMed databases. The search was focused on the ability of different implant connections to maintain preload, resist deformation after tightening and retightening, and prevent microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full-text reading. Results: The literature search conducted for this review initially resulted in 68 articles, among which 19 articles and 1 systematic review fulfilled the criteria for inclusion. The studies were divided according to the three proposed objectives, with some studies falling into more than one category (maintenance of preload, surface abutment-implant deformation, and resistance to microleakage). Conclusions: Conical abutment appears to result in fewer mechanical complications, such as screw loosening or fractures, and higher torque preservation. After SEM evaluation, damage was observed in the threads of the abutment screws, before and after loading in internal and external connections. Internal hexagon implants and predominantly internal conical (Morse taper) implants showed less microleakage in dynamic loading conditions. We suggest further studies to guarantee excellence in methodological quality.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 50 条
  • [31] Effect of fluid contamination on the reverse torque values of abutment screws at implant-abutment connections
    Koosha, Sara
    Toraji, Sedigheh
    Mostafavi, Azam S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (04): : 618 - 621
  • [32] Biofilm Affecting the Mechanical Integrity of Implant-Abutment Joints
    Prado, Abraao M.
    Pereira, Jorge
    Henriques, Bruno
    Benfatti, Cesar A. M.
    Magini, Ricardo S.
    Lopez-Lopez, Jose
    Souza, Julio C. M.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (04) : 381 - 383
  • [33] Antimicrobial Efficacy and Permeability of Various Sealing Materials in Two Different Types of Implant-Abutment Connections
    Smojver, Igor
    Bjelica, Roko
    Vuletic, Marko
    Gerbl, Drazena
    Budimir, Ana
    Gabric, Dragana
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (14)
  • [34] Molecular leakage at implant-abutment connection-in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration
    Harder, Soenke
    Dimaczek, Birka
    Acil, Yaha
    Terheyden, Hendrik
    Freitag-Wolf, Sandra
    Kern, Matthias
    CLINICAL ORAL INVESTIGATIONS, 2010, 14 (04) : 427 - 432
  • [35] Non-linear 3D Evaluation of Different Oral Implant-Abutment Connections
    Streckbein, P.
    Streckbein, R. G.
    Wilbrand, J. F.
    Malik, C. Y.
    Schaaf, H.
    Howaldt, H. P.
    Flach, M.
    JOURNAL OF DENTAL RESEARCH, 2012, 91 (12) : 1184 - 1189
  • [36] PHOTOELASTIC STRESS ANALYSIS OF EXTERNAL VERSUS INTERNAL IMPLANT-ABUTMENT CONNECTIONS
    Asvanund, Pattapon
    Morgano, Steven M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (04): : 266 - 271
  • [37] Analytical approach to determine the rotational freedom of dental implant-abutment connections
    Kraft, S.
    Semper, W.
    Nelson, K.
    Krueger, T.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 1484 - 1487
  • [38] Dental Implants with Conical Implant-Abutment Interface: Influence of the Conical Angle Difference on the Mechanical Behavior of the Implant
    Aguirrebeitia, Josu
    Abasolo, Mikel
    Vallejo, Javier
    Ansola, Ruben
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : E72 - E82
  • [39] In vitro assessment of connection strength and stability of internal implant-abutment connections
    Kofron, Michelle D.
    Carstens, Matthew
    Fu, Cong
    Wen, Hai Bo
    CLINICAL BIOMECHANICS, 2019, 65 : 92 - 99
  • [40] A Strain Gauge Analysis Comparing External and Internal Implant-Abutment Connections
    Asvanund, Pattapon
    IMPLANT DENTISTRY, 2014, 23 (02) : 206 - 211