Review of the Mechanical Behavior of Different Implant-Abutment Connections

被引:54
|
作者
Vinhas, Ana Sofia [1 ]
Aroso, Carlos [2 ]
Salazar, Filomena [1 ]
Lopez-Jarana, Paula [1 ]
Rios-Santos, Jose Vicente [3 ]
Herrero-Climent, Mariano [4 ]
机构
[1] Inst Univ Ciencias Saude, Dept Periodontol, P-4585116 Gandra, Portugal
[2] Inst Univ Ciencias Saude, Dept Prosthodont, P-4585116 Gandra, Portugal
[3] Univ Seville, Sch Dent, Dept Periodontol, C Avicena S-N, Seville 41009, Spain
[4] Porto Dent Inst, P-4150518 Porto, Portugal
关键词
implant– abutment connection; preload; tightening torque; cyclic loading; misfit; microleakage; IN-VITRO EVALUATION; EXTERNAL-CONNECTION; TORQUE MAINTENANCE; BACTERIAL LEAKAGE; REMOVAL TORQUE; PRELOAD; HEXAGON; DESIGN; INTERFACE; FATIGUE;
D O I
10.3390/ijerph17228685
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Introduction: Different implant-abutment connections have been developed to reduce mechanical and biological failure. The most frequent complications are loss of preload, screw loosening, abutment or implant fracture, deformations at the different interfaces, and bacterial microleakage. Aim: To review the evidence indicating whether the implant-abutment connection type is significant regarding the following issues: (1) maintenance of the preload in static and dynamic in vitro studies; (2) assessment of possible deformations at the implant-abutment interfaces, after repeated application of the tightening torque; (3) evaluation of the sealing capability of different implant connections against microleakage. Materials and Methods: In June 2020, an electronic literature search was performed in Medline, EBSCO host, and PubMed databases. The search was focused on the ability of different implant connections to maintain preload, resist deformation after tightening and retightening, and prevent microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full-text reading. Results: The literature search conducted for this review initially resulted in 68 articles, among which 19 articles and 1 systematic review fulfilled the criteria for inclusion. The studies were divided according to the three proposed objectives, with some studies falling into more than one category (maintenance of preload, surface abutment-implant deformation, and resistance to microleakage). Conclusions: Conical abutment appears to result in fewer mechanical complications, such as screw loosening or fractures, and higher torque preservation. After SEM evaluation, damage was observed in the threads of the abutment screws, before and after loading in internal and external connections. Internal hexagon implants and predominantly internal conical (Morse taper) implants showed less microleakage in dynamic loading conditions. We suggest further studies to guarantee excellence in methodological quality.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 50 条
  • [11] The micromechanical behavior of implant-abutment connections under a dynamic load protocol
    Zipprich, Holger
    Weigl, Paul
    Ratka, Christoph
    Lange, Bodo
    Lauer, Hans-Christoph
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (05) : 814 - 823
  • [12] Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth
    Martin-Gili, D.
    Molmeneu, M.
    Fernandez, M.
    Punset, M.
    Giner, Ll
    Armengou, J.
    Gil, F. Javier
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2015, 26 (07)
  • [13] Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth
    D. Martin-Gili
    M. Molmeneu
    M. Fernandez
    M. Punset
    Ll. Giner
    J. Armengou
    F. Javier Gil
    Journal of Materials Science: Materials in Medicine, 2015, 26
  • [14] Axial Displacement in Cement-Retained Prostheses with Different Implant-Abutment Connections
    Ko, Kyung-Ho
    Huh, Yoon-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (05) : 1093 - 1099
  • [15] Sealing effectiveness against Staphylococcus aureus of five different implant-abutment connections
    Discepoli, Nicola
    Cagidiaco, Edoardo Ferrari
    Landini, Giulia
    Pallecchi, Lucia
    Garcia-Godoy, Franklin
    Ferrari, Marco
    AMERICAN JOURNAL OF DENTISTRY, 2018, 31 (03): : 141 - 143
  • [16] Assessment of lipopolysaccharide microleakage at conical implant-abutment connections
    Sönke Harder
    Elgar Susanne Quabius
    Lars Ossenkop
    Matthias Kern
    Clinical Oral Investigations, 2012, 16 : 1377 - 1384
  • [17] Implant-Abutment Connections: A Review of Biologic Consequences and Peri-implantitis Implications
    Sasada, Yuya
    Cochran, David L.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (06) : 1296 - 1307
  • [18] Fatigue induced changes in conical implant-abutment connections
    Blum, Kai
    Wiest, Wolfram
    Fella, Christian
    Balles, Andreas
    Dittmann, Jonas
    Rack, Alexander
    Maier, Dominik
    Thomann, Ralf
    Spies, Benedikt Christopher
    Kohal, Ralf Joachim
    Zabler, Simon
    Nelson, Katja
    DENTAL MATERIALS, 2015, 31 (11) : 1415 - 1426
  • [19] Assessment of lipopolysaccharide microleakage at conical implant-abutment connections
    Harder, Soenke
    Quabius, Elgar Susanne
    Ossenkop, Lars
    Kern, Matthias
    CLINICAL ORAL INVESTIGATIONS, 2012, 16 (05) : 1377 - 1384
  • [20] Load Fatigue Performance of Conical Implant-Abutment Connections
    Seetoh, Y. L.
    Tan, Keson B.
    Chua, E. K.
    Quek, H. C.
    Nicholls, Jack I.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (04) : 797 - 806