Micro-CT artifacts reduction based on detector random shifting and fast data inpainting

被引:26
|
作者
Zhu, Yining [1 ]
Zhao, Mengliu [1 ]
Li, Hongwei [1 ]
Zhang, Peng [1 ]
机构
[1] Capital Normal Univ, Sch Math, CT Lab, Beijing 10048, Peoples R China
基金
中国国家自然科学基金;
关键词
Micro-CT; scintillator defects; artifacts reduction; detector random shifting; exemplar-based data inpainting; multiscale; RING ARTIFACTS; OBJECT REMOVAL; MODEL; WAVELET; STRIPE;
D O I
10.1118/1.4790697
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In Micro-CT systems based on optical coupling detectors, the defects of scintillator or CCD-camera would lead to heavy artifacts in reconstructed CT images. Meanwhile, different detector units usually suffer from inhomogeneous response, which also leads to artifacts in the CT images. Detector shifting is a simple and efficient method to remove the artifacts due to inhomogeneous responses of detector units. However, it does not work well for heavy artifacts due to defects in scintillator or CCD. The purpose of this paper is to develop a data preprocessing method to reduce both kinds of artifacts. Methods: A hybrid method which involves detector random shifting and data inpainting is proposed to correct the projection data, so as to suppress the artifacts in the reconstructed CT images. The defects in scintillator or CCD-camera lead to data lost in some areas of the projection data. The Criminisi algorithm is employed to recover the lost data. By detector random shifting, the location of the lost data in one view might be shifted away in adjacent views. This feature is utilized to design the search window, such that the best match patch shall be searched across adjacent views. By this way, the best match patches should really enjoy high similarity. As a result, the heavy artifacts due to defects of scintillator or CCD-camera should be suppressed. Furthermore, a multiscale tessellation method is proposed to locate the defects and similarity patches, which makes the Criminisi algorithm very fast. Results: The authors tested the proposed method on both simulated projection data and real projection data. Experiments show that the proposed method could correct the bad data in the projections quite well. Compared to other popular methods, such as linear interpolation, wavelet combining Fourier transform, and TV-inpainting, experimental results suggest that the CT images reconstructed from the preprocessed data sets by our method is significantly better in quality. Conclusions: They have proposed a hybrid method for projection data preprocessing which fits well to typical Micro-CT systems. The hybrid method could suppress the ring artifacts in the reconstructed CT images efficiently, while the spatial resolution is not reduced even with a critical eye. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Fast X-Ray CT Metal Artifacts Reduction Based on Noniterative Sinogram Inpainting
    Zhang, Yi
    Pu, Yi-Fei
    Ru, Jin-Rong
    Zhou, Ji-Liu
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2462 - 2464
  • [2] Interior micro-CT with an offset detector
    Sen Sharma, Kriti
    Gong, Hao
    Ghasemalizadeh, Omid
    Yu, Hengyong
    Wang, Ge
    Cao, Guohua
    MEDICAL PHYSICS, 2014, 41 (06)
  • [3] A model for clubfoot based on micro-CT data
    Windisch, Gunther
    Salaberger, Dietmar
    Rosmarin, Walter
    Kastner, Johann
    Exner, Gerhard Ulrich
    Haldi-Brandle, Verena
    Anderhuber, Friedrich
    JOURNAL OF ANATOMY, 2007, 210 (06) : 761 - 766
  • [4] Multidomain CT Metal Artifacts Reduction Using Partial Convolution Based Inpainting
    Pimkin, Artem
    Samoylenko, Alexander
    Antipina, Natalia
    Ovechkina, Anna
    Golanov, Andrey
    Dalechina, Alexandra
    Belyaev, Mikhail
    2020 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2020,
  • [5] Inpainting micro-CT images of fibrous materials using deep learning
    Karamov, Radmir
    Lomov, Stepan, V
    Sergeichev, Ivan
    Swolfs, Yentl
    Akhatov, Iskander
    COMPUTATIONAL MATERIALS SCIENCE, 2021, 197
  • [6] X-ray CT metal artifacts reduction through curvature based sinogram inpainting
    Department of Engineering Physics, Tsinghua University, Beijing, 100084, China
    不详
    J X Ray Sci Technol, 2006, 2 (73-82):
  • [7] X-ray CT metal artifacts reduction through curvature based sinogram inpainting
    Gu, Jianwei
    Zhang, Li
    Yu, Guoqiang
    Xing, Yuxiang
    Chen, Zhiqiang
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2006, 14 (02) : 73 - 82
  • [8] A new CT metal artifacts reduction algorithm based on fractional-order sinogram inpainting
    Zhang, Yi
    Pu, Yi-Fei
    Hu, Jin-Rong
    Liu, Yan
    Zhou, Ji-Liu
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (03) : 373 - 384
  • [9] Reducing the Formation of Image Artifacts during Spectroscopic Micro-CT Acquisitions
    Zuber, Marcus
    Koenig, Thomas
    Hussain, Rubaiya
    Hamann, Elias
    Ballabriga, Rafael
    Campbell, Michael
    Fauler, Alex
    Fiederle, Michael
    Baumbach, Tilo
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [10] Geometric calibration for a dual tube/detector micro-CT system
    Johnston, Samuel M.
    Johnson, G. Allan
    Badeaa, Cristian T.
    MEDICAL PHYSICS, 2008, 35 (05) : 1820 - 1829