Fast optimization and dose calculation in scanned ion beam therapy

被引:7
|
作者
Hild, S. [1 ,2 ,3 ,4 ]
Graeff, C. [5 ]
Trautmann, J. [5 ]
Kraemer, M. [5 ]
Zink, K. [4 ,6 ]
Durante, M. [5 ,7 ]
Bert, C. [2 ,3 ,5 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch GmbH, Dept Biophys, D-64291 Darmstadt, Germany
[2] Univ Clin Erlangen, Dept Radiat Oncol, D-91054 Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, D-91054 Erlangen, Germany
[4] Univ Appl Sci, Inst Med Phys & Radiat Protect, D-35390 Giessen, Germany
[5] GSI Helmholtzzentrum Schwerionenforsch GmbH, Dept Biophys, D-64289 Darmstadt, Germany
[6] Univ Hosp Giessen Marburg, Dept Radiotherapy & Radiooncol, D-35043 Marburg, Germany
[7] Tech Univ Darmstadt, Fac Phys, D-64289 Darmstadt, Germany
关键词
particle therapy; prostate cancer; adaptive treatment planning; fast dose calculation; RADIOTHERAPY; SYSTEM; CT; DESIGN; TUMORS; MODEL;
D O I
10.1118/1.4881522
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Particle therapy (PT) has advantages over photon irradiation on static tumors. An increased biological effectiveness and active target conformal dose shaping are strong arguments for PT. However, the sensitivity to changes of internal geometry complicates the use of PT for moving organs. In case of interfractionally moving objects adaptive radiotherapy (ART) concepts known from intensity modulated radiotherapy (IMRT) can be adopted for PT treatments. One ART strategy is to optimize a new treatment plan based on daily image data directly before a radiation fraction is delivered [treatment replanning (TRP)]. Optimizing treatment plans for PT using a scanned beam is a time consuming problem especially for particles other than protons where the biological effective dose has to be calculated. For the purpose of TRP, fast optimization and fast dose calculation have been implemented into the GSI in-house treatment planning system (TPS) TRiP98. Methods: This work reports about the outcome of a code analysis that resulted in optimization of the calculation processes as well as implementation of routines supporting parallel execution of the code. To benchmark the new features, the calculation time for therapy treatment planning has been studied. Results: Compared to the original version of the TPS, calculation times for treatment planning (optimization and dose calculation) have been improved by a factor of 10 with code optimization. The parallelization of the TPS resulted in a speedup factor of 12 and 5.5 for the original version and the code optimized version, respectively. Hence the total speedup of the new implementation of the authors' TPS yielded speedup factors up to 55. Conclusions: The improved TPS is capable of completing treatment planning for ion beam therapy of a prostate irradiation considering organs at risk in this has been overseen in the review process. Also see below 6 min. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Fast Pencil Beam Dose calculation for Proton Therapy Using a Double-Gaussian Beam Model
    da Silva, Joakim
    Ansorge, Richard
    Jena, Rajesh
    FRONTIERS IN ONCOLOGY, 2015, 5
  • [22] TREATMENT PLANNING FOR SCANNED ION BEAM THERAPY IN CLINICAL ROUTINE
    Ellerbrock, M.
    Ackermann, B.
    Brons, S.
    Heeg, P.
    Henkner, K.
    Ecker, S.
    Nairz, O.
    Winter, M.
    Mairani, A.
    Parodi, K.
    Jaekel, O.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S542 - S543
  • [23] SPATIAL DOSE UNIFORMITY MONITOR FOR ELECTRICALLY SCANNED ION-BEAM
    NATSUAKI, N
    OHYU, K
    TOKUYAMA, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1978, 49 (09): : 1300 - 1304
  • [24] A novel algorithm for the calculation of physical and biological irradiation quantities in scanned ion beam therapy: the beamlet superposition approach
    Russo, G.
    Attili, A.
    Battistoni, G.
    Bertrand, D.
    Bourhaleb, F.
    Cappucci, F.
    Ciocca, M.
    Mairani, A.
    Milian, F. M.
    Molinelli, S.
    Morone, M. C.
    Muraro, S.
    Orts, T.
    Patera, V.
    Sala, P.
    Schmitt, E.
    Vivaldo, G.
    Marchetto, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01): : 183 - 214
  • [25] Layout optimization of the beam spot locations scanned by electromagnets in particle beam therapy
    Sakamato, Yusuke
    Nagashima, Takayuki
    Sato, Yuki
    Izui, Kazuhiro
    Nishiwaki, Shiniji
    MECHANICAL ENGINEERING JOURNAL, 2022,
  • [26] A PENCIL BEAM ALGORITHM FOR HELIUM ION BEAM DOSE CALCULATION
    Fuchs, H.
    Stroebele, J.
    Schreiner, T.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S39 - S40
  • [27] Robustness of target dose coverage to motion uncertainties for scanned carbon ion beam tracking therapy of moving tumors
    Eley, John Gordon
    Newhauser, Wayne David
    Richter, Daniel
    Luechtenborg, Robert
    Saito, Nami
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (04): : 1717 - 1740
  • [28] Impact of spot size variations on dose in scanned proton beam therapy
    Kraan, A. C.
    Depauw, N.
    Clasie, B.
    Madden, T.
    Kooy, H. M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 58 - 64
  • [29] Fast electron beam simulation and dose calculation in radiotherapy
    Trindade, A
    Rodrigues, P
    Peralta, L
    Lopes, MC
    Alves, C
    Chaves, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (03): : 568 - 578
  • [30] Multigating, a 4D Optimized Beam Tracking in Scanned Ion Beam Therapy
    Graeff, Christian
    Constantinescu, Anna
    Luechtenborg, Robert
    Durante, Marco
    Bert, Christoph
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (06) : 497 - 504