The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis

被引:48
|
作者
Cha, Jae-Kook [1 ]
Paeng, Kyeongwon [1 ]
Jung, Ui-Won [1 ]
Choi, Seong-Ho [1 ]
Sanz, Mariano [2 ,3 ]
Sanz-Martin, Ignacio [2 ]
机构
[1] Yonsei Univ, Dept Periodontol, Coll Dent, Res Inst Periodontal Regenerat, 50-1 Yonsei Ro, Seoul 120752, South Korea
[2] Univ Complutense Madrid, Fac Odontol, Sect Grad Periodontol, Madrid, Spain
[3] Univ Complutense Madrid, ETEP Etiol & Therapy Periodontal Dis Res Grp, Madrid, Spain
关键词
confocal microscope; dental implants; peri-implantitis; scanning electron microscope; surface decontamination; surface macrotopography; titanium; TITANIUM DENTAL IMPLANTS; ULTRASONIC SCALER TIPS; HUMAN GINGIVAL FIBROBLASTS; PERI-IMPLANTITIS; PROLIFERATION; ATTACHMENT; DECONTAMINATION; DEBRIDEMENT; VIABILITY; REMOVAL;
D O I
10.1111/clr.13446
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To evaluate in vitro the changes in implant surface topography and roughness of commercial implants after instrumentation with five decontamination protocols. Material and methods Seventy-two titanium implants with a sandblasted and acid-etched (SLA) surface were placed 5 mm supra-crestally. Five groups of twelve implants were instrumented with the following protocols: a metal scaler tip (SCAL), a thermoplastic scaler tip (PEEK), a round titanium brush (RBRU), a tufted brush with titanium bristles (TNBRU), and a glycine-based air-powder abrasive (GLYC). A sixth group with untreated implants was used as control. Scanning electron microscope and confocal laser scanning microscope were utilized to evaluate the changes in the implant surfaces. Results The SCAL caused pronounced macroscopic alterations and damage of the implant surface, the PEEK left remnants of the plastic tip in the implant surface, and both titanium brush groups flattened the thread profile, while minimal alterations were observed in the GLYC. When compared to the control group, the roughness parameters (Sa) in the buccal aspect increased in the thread area of SCAL, and a minor reduction was observed in the PEEK while in the other groups, these values remained unchanged. In the valley areas, however the RBRU, TNBRU, and GLYC experienced a significant reduction (smoothening) indicating different accessibility of the decontamination protocols to the thread and valley. Similarly, the buccal aspects had more pronounced changes than those in the palatal aspect. Conclusion Within the limitations of this in vitro investigation, the tested protocols induced different macroscopic alterations and surface roughness changes that varied in the thread and valley area.
引用
收藏
页码:578 / 587
页数:10
相关论文
共 50 条
  • [31] Autofluorescence of chloroplasts measured by a laser scanning confocal microscope
    Feng Q.
    Wang W.
    Li H.
    Pan X.
    Pan, Xun (panx@biomed.tsinghua.edu.cn), 1600, Tsinghua University (57): : 651 - 654and660
  • [32] A scanning force microscope combined with a scanning electron microscope for multidimensional data analysis
    Troyon, M
    Lei, HN
    Wang, ZH
    Shang, GY
    MICROSCOPY MICROANALYSIS MICROSTRUCTURES, 1997, 8 (06): : 393 - 402
  • [33] Confocal laser scanning microscope in the cell biology investigations
    Sobol, MA
    Yatsenko, VA
    CAOL 2005: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ADVANCED OPTOELECTRONICS AND LASERS, VOL 1, 2005, : 303 - 305
  • [34] Confocal scanning Laser holography, and an associated microscope: A proposal
    Herring, RA
    OPTIK, 1997, 105 (02): : 65 - 68
  • [35] Lateral Resolution Test for Confocal Laser Scanning Microscope
    Cui, J. J.
    MICRO-NANO TECHNOLOGY XV, 2014, 609-610 : 1159 - 1164
  • [36] Resolution in the ApoTome and the confocal laser scanning microscope: comparison
    Weigel, Arwed
    Schild, Detlev
    Zeug, Andre
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (01)
  • [37] Confocal scanning laser holography, and an associated microscope: a proposal
    Herring, R.A.
    Optik (Jena), 1997, 105 (02): : 65 - 68
  • [38] USE OF CONFOCAL LASER-SCANNING MICROSCOPE IN CYTOCHEMISTRY
    TAKAMATSU, T
    FUJITA, S
    ACTA HISTOCHEMICA ET CYTOCHEMICA, 1994, 27 (05) : 495 - 498
  • [39] Microscopic Spectrophotometry Using Confocal Laser Scanning Microscope
    Matsumoto, Tomoko
    Shiraki, Ryuichi
    Matsumoto, Jin
    Shiragami, Tsutomu
    Yasuda, Masahide
    BUNSEKI KAGAKU, 2008, 57 (10) : 819 - 824
  • [40] SPHERICAL-COORDINATE SCANNING CONFOCAL LASER MICROSCOPE
    DOUKOGLOU, TD
    HUNTER, IW
    OPTICAL ENGINEERING, 1995, 34 (07) : 2103 - 2108