The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis

被引:48
|
作者
Cha, Jae-Kook [1 ]
Paeng, Kyeongwon [1 ]
Jung, Ui-Won [1 ]
Choi, Seong-Ho [1 ]
Sanz, Mariano [2 ,3 ]
Sanz-Martin, Ignacio [2 ]
机构
[1] Yonsei Univ, Dept Periodontol, Coll Dent, Res Inst Periodontal Regenerat, 50-1 Yonsei Ro, Seoul 120752, South Korea
[2] Univ Complutense Madrid, Fac Odontol, Sect Grad Periodontol, Madrid, Spain
[3] Univ Complutense Madrid, ETEP Etiol & Therapy Periodontal Dis Res Grp, Madrid, Spain
关键词
confocal microscope; dental implants; peri-implantitis; scanning electron microscope; surface decontamination; surface macrotopography; titanium; TITANIUM DENTAL IMPLANTS; ULTRASONIC SCALER TIPS; HUMAN GINGIVAL FIBROBLASTS; PERI-IMPLANTITIS; PROLIFERATION; ATTACHMENT; DECONTAMINATION; DEBRIDEMENT; VIABILITY; REMOVAL;
D O I
10.1111/clr.13446
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To evaluate in vitro the changes in implant surface topography and roughness of commercial implants after instrumentation with five decontamination protocols. Material and methods Seventy-two titanium implants with a sandblasted and acid-etched (SLA) surface were placed 5 mm supra-crestally. Five groups of twelve implants were instrumented with the following protocols: a metal scaler tip (SCAL), a thermoplastic scaler tip (PEEK), a round titanium brush (RBRU), a tufted brush with titanium bristles (TNBRU), and a glycine-based air-powder abrasive (GLYC). A sixth group with untreated implants was used as control. Scanning electron microscope and confocal laser scanning microscope were utilized to evaluate the changes in the implant surfaces. Results The SCAL caused pronounced macroscopic alterations and damage of the implant surface, the PEEK left remnants of the plastic tip in the implant surface, and both titanium brush groups flattened the thread profile, while minimal alterations were observed in the GLYC. When compared to the control group, the roughness parameters (Sa) in the buccal aspect increased in the thread area of SCAL, and a minor reduction was observed in the PEEK while in the other groups, these values remained unchanged. In the valley areas, however the RBRU, TNBRU, and GLYC experienced a significant reduction (smoothening) indicating different accessibility of the decontamination protocols to the thread and valley. Similarly, the buccal aspects had more pronounced changes than those in the palatal aspect. Conclusion Within the limitations of this in vitro investigation, the tested protocols induced different macroscopic alterations and surface roughness changes that varied in the thread and valley area.
引用
收藏
页码:578 / 587
页数:10
相关论文
共 50 条
  • [21] Optical spectrometer for a confocal scanning laser microscope
    1600, Found Adv Med Sci Inc, Mahwah, NJ, USA (17):
  • [22] A video rate laser scanning confocal microscope
    Ma, Hongzhou
    Jiang, James
    Ren, Hongwu
    Cable, Alex E.
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XV, 2008, 6861
  • [23] A SETUP FOR A CONFOCAL SCANNING LASER INTERFERENCE MICROSCOPE
    STELZER, EHK
    MARSMAN, HJB
    VANRESANDT, RWW
    OPTIK, 1986, 73 (01): : 30 - 33
  • [24] AN OPTICAL SPECTROMETER FOR A CONFOCAL SCANNING LASER MICROSCOPE
    TREPTE, O
    SCANNING, 1995, 17 (03) : 171 - 174
  • [25] Roughness measurement of rock discontinuities using a confocal laser scanning microscope and the Fourier spectral analysis
    Chae, BG
    Ichikawa, Y
    Jeong, GC
    Seo, YS
    Kim, BC
    ENGINEERING GEOLOGY, 2004, 72 (3-4) : 181 - 199
  • [26] The analysis of confocal fluorescent microscope with laser scanning microarray system
    Yuan, W
    Ma, JS
    Fu, DX
    Hou, LL
    Chen, JB
    Holography, Diffractive Optics, and Applications II, Pts 1 and 2, 2005, 5636 : 455 - 458
  • [27] CONFOCAL SCANNING LASER - SCANNING PROBE HYBRID MICROSCOPE FOR BIOLOGICAL APPLICATIONS
    SCHABERT, F
    KNAPP, H
    KARRASCH, S
    HARING, R
    ENGEL, A
    ULTRAMICROSCOPY, 1994, 53 (02) : 147 - 157
  • [28] Variable-ambient scanning stage for a laser scanning confocal microscope
    Sirbuly, DJ
    Schmidt, JP
    Mason, MD
    Summers, MA
    Buratto, SK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (10): : 4366 - 4368
  • [29] MEASUREMENT OF SMALL ROUGHNESS OF SPECIMEN SURFACE BY SCANNING ELECTRON-MICROSCOPE
    SOEZIMA, H
    HIRAI, T
    JOURNAL OF ELECTRON MICROSCOPY, 1977, 26 (03): : 272 - 272
  • [30] Evaluation of caries inhibition effect with confocal laser scanning microscope.
    Okuda, M
    Pereira, PNR
    Nikaido, T
    Yoshimitsu, K
    Tagami, J
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 147 - 147