The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis

被引:48
|
作者
Cha, Jae-Kook [1 ]
Paeng, Kyeongwon [1 ]
Jung, Ui-Won [1 ]
Choi, Seong-Ho [1 ]
Sanz, Mariano [2 ,3 ]
Sanz-Martin, Ignacio [2 ]
机构
[1] Yonsei Univ, Dept Periodontol, Coll Dent, Res Inst Periodontal Regenerat, 50-1 Yonsei Ro, Seoul 120752, South Korea
[2] Univ Complutense Madrid, Fac Odontol, Sect Grad Periodontol, Madrid, Spain
[3] Univ Complutense Madrid, ETEP Etiol & Therapy Periodontal Dis Res Grp, Madrid, Spain
关键词
confocal microscope; dental implants; peri-implantitis; scanning electron microscope; surface decontamination; surface macrotopography; titanium; TITANIUM DENTAL IMPLANTS; ULTRASONIC SCALER TIPS; HUMAN GINGIVAL FIBROBLASTS; PERI-IMPLANTITIS; PROLIFERATION; ATTACHMENT; DECONTAMINATION; DEBRIDEMENT; VIABILITY; REMOVAL;
D O I
10.1111/clr.13446
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To evaluate in vitro the changes in implant surface topography and roughness of commercial implants after instrumentation with five decontamination protocols. Material and methods Seventy-two titanium implants with a sandblasted and acid-etched (SLA) surface were placed 5 mm supra-crestally. Five groups of twelve implants were instrumented with the following protocols: a metal scaler tip (SCAL), a thermoplastic scaler tip (PEEK), a round titanium brush (RBRU), a tufted brush with titanium bristles (TNBRU), and a glycine-based air-powder abrasive (GLYC). A sixth group with untreated implants was used as control. Scanning electron microscope and confocal laser scanning microscope were utilized to evaluate the changes in the implant surfaces. Results The SCAL caused pronounced macroscopic alterations and damage of the implant surface, the PEEK left remnants of the plastic tip in the implant surface, and both titanium brush groups flattened the thread profile, while minimal alterations were observed in the GLYC. When compared to the control group, the roughness parameters (Sa) in the buccal aspect increased in the thread area of SCAL, and a minor reduction was observed in the PEEK while in the other groups, these values remained unchanged. In the valley areas, however the RBRU, TNBRU, and GLYC experienced a significant reduction (smoothening) indicating different accessibility of the decontamination protocols to the thread and valley. Similarly, the buccal aspects had more pronounced changes than those in the palatal aspect. Conclusion Within the limitations of this in vitro investigation, the tested protocols induced different macroscopic alterations and surface roughness changes that varied in the thread and valley area.
引用
收藏
页码:578 / 587
页数:10
相关论文
共 50 条
  • [1] Roughness analysis from tablet surfaces with a Confocal Laser Scanning Microscope
    Peltonen, L
    Mannermaa, JP
    Yliruusi, J
    PHARMAZIE, 1997, 52 (11): : 860 - 863
  • [2] CHARACTERIZATION OF SURFACE TOPOGRAPHY WITH SCANNING ELECTRON MICROSCOPE
    PRUDEN, LH
    KORDA, EJ
    WILLIAMS, JP
    AMERICAN CERAMIC SOCIETY BULLETIN, 1967, 46 (08): : 750 - &
  • [3] CHARACTERIZATION OF SURFACE TOPOGRAPHY WITH SCANNING ELECTRON MICROSCOPE
    PRUDEN, LH
    KORDA, EJ
    WILLIAMS, JP
    AMERICAN CERAMIC SOCIETY BULLETIN, 1966, 45 (09): : 813 - &
  • [4] Confocal laser scanning microscope
    不详
    OPTICS AND LASER TECHNOLOGY, 1997, 29 (03): : R7 - R7
  • [5] Scanning electron microscope analysis of the root surface after instrumentation
    Marques, Sandra
    Ramos, Renata
    Pinto, Miguel
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2007, 48 (02): : 81 - 86
  • [6] SURFACE ROUGHNESS DETERMINATION USING LASER SCANNING CONFOCAL MICROSCOPE ZEISS LSM 700
    Bezak, Tomas
    Kusy, Martin
    Elias, Michal
    Kopcek, Michal
    METAL 2013: 22ND INTERNATIONAL CONFERENCE ON METALLURGY AND MATERIALS, 2013, : 947 - 952
  • [7] SURFACE ROUGHNESS MEASUREMENT BY SCANNING ELECTRON MICROSCOPE (SEM).
    Sato, Hisayoshi
    Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 1983, 49 (438): : 227 - 234
  • [8] Enhanced scanning control in a confocal scanning laser microscope
    Trepte, O
    SCANNING, 1996, 18 (05) : 356 - 361
  • [9] Non-contact surface morphology analysis of CO2 laser-irradiated teeth by scanning electron microscope and confocal laser scanning, microscope
    Yamada, MK
    Uo, M
    Ohkawa, S
    Akasaka, T
    Watari, A
    MATERIALS TRANSACTIONS, 2004, 45 (04) : 1033 - 1040
  • [10] Waveguide Roughness Measuring Metrology with Confocal Laser Scanning Microscope (CLSM)
    Shang, Hongpeng
    Sun, DeGui
    Jiang, Huilin
    2018 IEEE INTERNATIONAL CONFERENCE ON MANIPULATION, MANUFACTURING AND MEASUREMENT ON THE NANOSCALE (3M-NANO) - CONFERENCE PROCEEDINGS, 2018, : 155 - 158