Continuous-Flow Microelectroextraction for Enrichment of Low Abundant Compounds

被引:20
|
作者
Schoonen, Jan-Willem [1 ,2 ]
van Duinen, Vincent [1 ,2 ]
Oedit, Arnar [1 ,2 ]
Vulto, Paul [1 ,2 ]
Hankemeier, Thomas [1 ,2 ]
Lindenburg, Petrus W. [1 ,2 ]
机构
[1] Leiden Univ, Leiden Acad Ctr Drug Res, Div Analyt Biosci, Leiden, Netherlands
[2] Netherlands Metab Ctr, Leiden, Netherlands
关键词
SAMPLE PREPARATION; ELECTROEXTRACTION; SEPARATION; PRECONCENTRATION; ELECTROPHORESIS; CARNITINE; ACYLCARNITINES; FEASIBILITY; METABOLITES; EXTRACTION;
D O I
10.1021/ac500707v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a continuous-flow microelectroextraction flow cell that allows for electric field enhanced extraction of analytes from a large volume (1 mL) of continuously flowing donor phase into a micro volume of stagnant acceptor phase (13.4 mu L). We demonstrate for the first time that the interface between the stagnant acceptor phase and fast-flowing donor phase can be stabilized by a phaseguide. Chip performance was assessed by visual experiments using crystal violet. Then, extraction of a mixture of acylcarnitines was assessed by off-line coupling to reversed phase liquid chromatography coupled to time-of-flight mass spectrometry, resulting in concentration factors of 80.0 +/- 9.2 times for hexanoylcarnitine, 73.8 +/- 9.1 for octanoylcarnitine, and 34.1 +/- 4.7 times for lauroylcarnitine, corresponding to recoveries of 107.8 +/- 12.3%, 98.9 +/- 12.3%, and 45.7 +/- 6.3%, respectively, in a sample of 500 mu L delivered at a flow of 50 mu L min(-1) under an extraction voltage of 300 V. Finally, the method was applied to the analysis of acylcarnitines spiked to urine, resulting in detection limits as low as 0.3-2 nM. Several putative endogenous acylcarnitines were found. The current flowing-to-stagnant phase microelectroextraction setup allows for the extraction of milliliter range volumes and is, as a consequence, very suited for analysis of low-abundant metabolites.
引用
收藏
页码:8048 / 8056
页数:9
相关论文
共 50 条
  • [41] Continuous-flow peritoneal dialysis
    Amerling, R
    Ronco, C
    Levin, NW
    PERITONEAL DIALYSIS INTERNATIONAL, 2000, 20 : S172 - S177
  • [42] STUDIES OF A CONTINUOUS-FLOW PINCH
    ABAS, S
    ELFAYOUMI, MKK
    PLASMA PHYSICS AND CONTROLLED FUSION, 1977, 19 (08) : 715 - 736
  • [43] IMPROVEMENTS IN CONTINUOUS-FLOW ANALYSIS
    CONETTA, A
    DORSHEIMER, WT
    DUCROS, MJF
    AMERICAN LABORATORY, 1981, 13 (09) : 116 - &
  • [44] CONTINUOUS-FLOW APNEIC VENTILATION
    SMITH, RB
    BABINSKI, M
    BUNEGIN, L
    GILBERT, J
    SWARTZMAN, S
    DIRTING, J
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1984, 28 (06) : 631 - 639
  • [45] Continuous-Flow Meerwein Arylation
    Vinay G. Bhaya
    Ramesh A. Joshi
    Amol A. Kulkarni
    Journal of Flow Chemistry, 2014, 4 : 211 - 216
  • [46] A MULTICHANNEL CONTINUOUS-FLOW ANALYZER
    THIERS, RE
    BRYAN, J
    OGLESBY, K
    CLINICAL CHEMISTRY, 1966, 12 (03) : 120 - &
  • [47] CONTINUOUS-FLOW INTERSECTIONS - RESPONSE
    GOLDBLATT, R
    ITE JOURNAL-INSTITUTE OF TRANSPORTATION ENGINEERS, 1995, 65 (11): : 17 - 17
  • [48] CONTINUOUS-FLOW NITROGEN TRAP
    VEZIROV, KN
    VEZIROVA, MG
    IBRAGIMOV, IN
    MAMEDBEILI, IA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1994, 37 (05) : 665 - 666
  • [49] Continuous-Flow Meerwein Arylation
    Bhaya, Vinay G.
    Joshi, Ramesh A.
    Kulkarni, Amol A.
    JOURNAL OF FLOW CHEMISTRY, 2014, 4 (04) : 211 - 216
  • [50] CONTINUOUS-FLOW ULTRAVIOLET MICRODENSITOMETER
    KAMINIR, LB
    UNDRITSOV, IM
    AGROSKIN, LS
    KREINDLIN, EY
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1971, 14 (05): : 1478 - +