Continuous-Flow Microelectroextraction for Enrichment of Low Abundant Compounds

被引:20
|
作者
Schoonen, Jan-Willem [1 ,2 ]
van Duinen, Vincent [1 ,2 ]
Oedit, Arnar [1 ,2 ]
Vulto, Paul [1 ,2 ]
Hankemeier, Thomas [1 ,2 ]
Lindenburg, Petrus W. [1 ,2 ]
机构
[1] Leiden Univ, Leiden Acad Ctr Drug Res, Div Analyt Biosci, Leiden, Netherlands
[2] Netherlands Metab Ctr, Leiden, Netherlands
关键词
SAMPLE PREPARATION; ELECTROEXTRACTION; SEPARATION; PRECONCENTRATION; ELECTROPHORESIS; CARNITINE; ACYLCARNITINES; FEASIBILITY; METABOLITES; EXTRACTION;
D O I
10.1021/ac500707v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a continuous-flow microelectroextraction flow cell that allows for electric field enhanced extraction of analytes from a large volume (1 mL) of continuously flowing donor phase into a micro volume of stagnant acceptor phase (13.4 mu L). We demonstrate for the first time that the interface between the stagnant acceptor phase and fast-flowing donor phase can be stabilized by a phaseguide. Chip performance was assessed by visual experiments using crystal violet. Then, extraction of a mixture of acylcarnitines was assessed by off-line coupling to reversed phase liquid chromatography coupled to time-of-flight mass spectrometry, resulting in concentration factors of 80.0 +/- 9.2 times for hexanoylcarnitine, 73.8 +/- 9.1 for octanoylcarnitine, and 34.1 +/- 4.7 times for lauroylcarnitine, corresponding to recoveries of 107.8 +/- 12.3%, 98.9 +/- 12.3%, and 45.7 +/- 6.3%, respectively, in a sample of 500 mu L delivered at a flow of 50 mu L min(-1) under an extraction voltage of 300 V. Finally, the method was applied to the analysis of acylcarnitines spiked to urine, resulting in detection limits as low as 0.3-2 nM. Several putative endogenous acylcarnitines were found. The current flowing-to-stagnant phase microelectroextraction setup allows for the extraction of milliliter range volumes and is, as a consequence, very suited for analysis of low-abundant metabolites.
引用
收藏
页码:8048 / 8056
页数:9
相关论文
共 50 条
  • [21] CONTINUOUS-FLOW ENTHALPIMETRY
    PRIESTLE.PT
    SEBBORN, WS
    SELMAN, RFW
    ANALYST, 1965, 90 (1075) : 589 - &
  • [22] Lignin oxidative depolymerization to phenolic compounds in a continuous-flow manufacturing platform
    Lian, Pengfei
    Liu, Shuangjie
    Ma, Zihao
    Wang, Xing
    Han, Ying
    INDUSTRIAL CROPS AND PRODUCTS, 2024, 212
  • [23] Review of Gasification of Organic Compounds in Continuous-Flow, Supercritical Water Reactors
    Pinkard, Brian R.
    Gorman, David J.
    Tiwari, Kartik
    Kramlich, John C.
    Reinhall, Per G.
    Novosselov, Igor V.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (10) : 3471 - 3481
  • [24] DETERMINATION OF LOW SURFACE-AREAS BY CONTINUOUS-FLOW METHOD
    LOWELL, S
    KARP, S
    ANALYTICAL CHEMISTRY, 1972, 44 (09) : 1706 - &
  • [25] CONTINUOUS-FLOW FLUOROMETRY OF LOW GALACTOSE CONCENTRATIONS IN BLOOD OR PLASMA
    HENDERSON, JM
    FALES, FW
    CLINICAL CHEMISTRY, 1980, 26 (02) : 282 - 285
  • [26] LOW RESULTS FOR INORGANIC PHOSPHORUS WITH THE SMAC CONTINUOUS-FLOW ANALYZER
    ROBERTSON, EA
    ELIN, RJ
    JOHNSON, E
    CLINICAL CHEMISTRY, 1981, 27 (03) : 490 - 492
  • [27] An inexpensive apparatus for up to 97% continuous-flow parahydrogen enrichment using liquid helium
    Du, Yong
    Zhou, Ronghui
    Ferrer, Maria-Jose
    Chen, Minda
    Graham, John
    Malphurs, Bill
    Labbe, Greg
    Huang, Wenyu
    Bowers, Clifford R.
    JOURNAL OF MAGNETIC RESONANCE, 2020, 321
  • [28] FLOW AND SEDIMENTATION IN CONTINUOUS-FLOW CENTRIFUGE
    REUTER, H
    CHEMIE INGENIEUR TECHNIK, 1967, 39 (5-6) : 311 - &
  • [29] CONTINUOUS-FLOW FILTRATION - LEUKOPHERESIS
    DJERASSI, I
    SUVANSRI, U
    MITRAKUL, C
    KIM, JS
    CIESIELKA, W
    TRANSFUSION, 1972, 12 (02) : 75 - +
  • [30] CONTINUOUS-FLOW ANALYSIS - THE AUTOANALYZER
    CRANDELL, C
    JOURNAL OF AUTOMATIC CHEMISTRY, 1985, 7 (03): : 145 - 148