A Comparison of the Mechanical Measures Used for Assessing Orthodontic Mini-Implant Stability

被引:9
|
作者
Hosein, Yara K. [1 ]
Dixon, S. Jeffrey [2 ]
Rizkalla, Amin S. [3 ]
Tassi, Ali [4 ]
机构
[1] Western Univ, Bone & Joint Inst, Schulich Sch Med & Dent, Div Grad Orthodont, London, ON, Canada
[2] Western Univ, Bone & Joint Inst, Schulich Sch Med & Dent, Dept Physiol & Pharmacol,Div Grad Orthodont, London, ON, Canada
[3] Western Univ, Schulich Sch Med Dent, Dept Chem & Biochem Engn, Div Grad Orthodont,Bone & Joint Inst,Fac Engn, London, ON, Canada
[4] Western Univ, Div Grad Orthodont, Schulich Sch Med & Dent, London, ON, Canada
关键词
torque; pull-out load; implant loosening; Periotest; mechanical retention; PULL-OUT STRENGTH; INSERTION TORQUE; SURFACE-TREATMENT; DAMPING CAPACITY; TAPER SHAPE; MINISCREWS; LENGTH; THREAD; IMPACT; DIAMETER;
D O I
10.1097/ID.0000000000000514
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:Mechanical loosening remains a common complication associated with mini-implant failure. The purpose of this study was to compare common mechanical measures of mini-implant stability to determine their association and reliability.Materials and Methods:Ninety self-drilling orthodontic mini-implants from 6 manufacturers were inserted into artificial bone blocks. Insertion torques (ITs) and Periotest values (PVs) were measured. Subsequently, mini-implants underwent pull-out testing for measures of pull-out load (POL) and screw displacement (ScrD). Stability measurements were compared using one-way ANOVA, associations among them were assessed using correlation analyses, and reliability was evaluated using coefficients of variation (COVs).Results:Variations in stability of mini-implants were found, specific to the mechanical measure used for assessment (P < 0.05). The strongest correlations were found between IT and PV (r = -0.68) and between IT and POL (r = 0.66). Overall, PV showed the greatest variability (COV: 11%-100%) compared with IT (11%), POL (4%), and ScrD (19%).Conclusions:IT, PV, and POLs only agreed moderately in their assessment of mini-implant stability, and Periotest showed the least reliability in predicting mini-implant stability. As such, independent and interchangeable use of these stability measures should be avoided.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [41] Bone density at interradicular sites: implications for orthodontic mini-implant placement
    Chun, Y. S.
    Lim, W. H.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2009, 12 (01) : 25 - 32
  • [42] Outcome of orthodontic mini-implant loss in relation to interleukin 6 polymorphisms
    Reichow, A. M.
    Melo, A. C.
    de Souza, C. M.
    Castilhos, B. B.
    Olandoski, M.
    Alvim-Pereira, C. C. K.
    Alvim-Pereira, F.
    Trevilatto, P. C.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (05) : 649 - 657
  • [43] Root and Bone Response to the Proximity of a Mini-Implant under Orthodontic Loading
    Lee, Yang-Ku
    Kim, Jong-Wan
    Baek, Seung-Hak
    Kim, Tae-Woo
    Chang, Young-Il
    ANGLE ORTHODONTIST, 2010, 80 (03) : 452 - 458
  • [44] Finite element simulation and statistical investigation of an orthodontic mini-implant's stability in a novel screw design
    Pouyafar, Vahid
    Meshkabadi, Ramin
    Sadr Haghighi, Amir Hooman
    Navid, Ali
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2021, 235 (09) : 1046 - 1057
  • [45] The effect of varying healing times on orthodontic mini-implant stability: a microscopic computerized tomographic and biomechanical analysis
    Zhang, Qiang
    Zhao, Lixing
    Wu, Yeke
    Wang, Hui
    Zhao, Zhihe
    Xu, Zhenrui
    Wei, Xing
    Tang, Tian
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 112 (04): : 423 - 429
  • [46] How Does Orthodontic Mini-Implant Thread Minidesign Influence the Stability?-Systematic Review with Meta-Analysis
    Jedlinski, Maciej
    Janiszewska-Olszowska, Joanna
    Mazur, Marta
    Grocholewicz, Katarzyna
    Suquia, Pedro Suarez
    Quintanilla, David Suarez
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (18)
  • [47] Orthodontic mini-implant stability in different healing times before loading: A microscopic computerized tomographic and biomechanical analysis
    Zhao, Lixing
    Xu, Zhenrui
    Yang, Zhi
    Wei, Xing
    Tang, Tian
    Zhao, Zhihe
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (02): : 196 - 202
  • [48] Analysis of the association of IL4 polymorphisms with orthodontic mini-implant loss
    Lopes, T. F.
    Souza, C. M.
    Reichow, A. M.
    Melo, A. C.
    Trevilatto, P. C.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 48 (07) : 982 - 988
  • [49] Replacing a failed mini-implant with a miniplate to prevent interruption during orthodontic treatment
    Lee, Jin-Hwa
    Choo, HyeRan
    Kim, Seong-Hun
    Chung, Kyu-Rhim
    Giannuzzi, Lucille A.
    Ngan, Peter
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 139 (06) : 849 - 857
  • [50] Quantitative assessment of orthodontic mini-implant displacement: The effect of initial force application
    Holst, Alexandra Ioana
    Karl, Matthias
    Karolczak, Marek
    Goellner, Matthias
    Holst, Stefan
    QUINTESSENCE INTERNATIONAL, 2010, 41 (01): : 59 - 66