NON-INVASIVE VASCULAR RADIAL/CIRCUMFERENTIAL STRAIN IMAGING AND WALL SHEAR RATE ESTIMATION USING VIDEO IMAGES OF DIAGNOSTIC ULTRASOUND

被引:16
|
作者
Wan, Jinjin [1 ]
He, Fangli [1 ]
Zhao, Yongfeng [2 ]
Zhang, Hongmei [1 ]
Zhou, Xiaodong [2 ]
Wan, Mingxi [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Life Sci & Technol, Dept Biomed Engn, Key Lab Biomed Informat Engn,Minist Educ, Xian 710049, Peoples R China
[2] Fourth Mil Med Univ, Xijing Hosp, Dept Ultrasound, Xian 710032, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2014年 / 40卷 / 03期
基金
中国国家自然科学基金;
关键词
Carotid; Atherosclerosis; Routine screening; Gray-scale correction; Radial strain; Circumferential strain; Transverse Doppler; Wall shear rate; IN-VIVO; INTRAVASCULAR ULTRASOUND; MYOCARDIAL ELASTOGRAPHY; BLOOD-FLOW; ELASTICITY; ATHEROSCLEROSIS; ARTERY; DISPLACEMENT; STRESS; RESOLUTION;
D O I
10.1016/j.ultrasmedbio.2013.10.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of this work was to develop a convenient method for radial/circumferential strain imaging and shear rate estimation that could be used as a supplement to the current routine screening for carotid atherosclerosis using video images of diagnostic ultrasound. A reflection model-based correction for gray-scale non-uniform distribution was applied to B-mode video images before strain estimation to improve the accuracy of radial/circumferential strain imaging when applied to vessel transverse cross sections. The incremental and cumulative radial/circumferential strain images can then be calculated based on the displacement field between consecutive B-mode images. Finally, the transverse Doppler spectra acquired at different depths along the vessel diameter were used to construct the spatially matched instantaneous wall shear values in a cardiac cycle. Vessel phantom simulation results revealed that the signal-to-noise ratio and contrast-to-noise ratio of the radial and circumferential strain images were increased by 2.8 and 5.9 dB and by 2.3 and 4.4 dB, respectively, after non-uniform correction. Preliminary results for 17 patients indicated that the accuracy of radial/circumferential strain images was improved in the lateral direction after non-uniform correction. The peak-to-peak value of incremental strain and the maximum cumulative strain for calcified plaques are evidently lower than those for other plaque types, and the echolucent plaques had higher values, on average, than the mixed plaques. Moreover, low oscillating wall shear rate values, found near the plaque and stenosis regions, are closely related to plaque formation. In conclusion, the method described can provide additional valuable results as a supplement to the current routine ultrasound examination for carotid atherosclerosis and, therefore, has significant potential as a feasible screening method for atherosclerosis diagnosis in the future. (E-mail:mxwan@mail.xjtu.edu.cn) (C) 2014 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:622 / 636
页数:15
相关论文
共 50 条
  • [41] Non-invasive assessment of skeletal muscle fibrosis in mice using nuclear magnetic resonance imaging and ultrasound shear wave elastography
    Martins-Bach, Aurea B.
    Bachasson, Damien
    Araujo, Ericky C. A.
    Soustelle, Lucas
    de Sousa, Paulo Loureiro
    Fromes, Yves
    Carlier, Pierre G.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [42] Non-invasive Estimation of Pressure Changes along a Streamline using Vector Velocity Ultrasound
    Olesen, Jacob Bjerring
    Villagomez-Hoyos, Carlos Armando
    Traberg, Marie Sand
    Jensen, Jorgen Arendt
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [43] Non-invasive estimation of vascular compliance and distensibility in the arm vessels: a novel ultrasound-based protocol
    Cappelletti, Sara
    Caimi, Alessandro
    Caldiroli, Alice
    Baroni, Irene
    Votta, Emiliano
    Riboldi, Stefania A.
    Marrocco-Trischitta, Massimiliano M.
    Redaelli, Alberto
    Sturla, Francesco
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (07) : 3515 - +
  • [44] Motion compensation algorithm for non-invasive two-dimensional temperature estimation using diagnostic pulse-echo ultrasound
    Simon, C
    VanBaren, P
    Ebbini, E
    SURGICAL APPLICATIONS OF ENERGY, PROCEEDINGS OF, 1998, 3249 : 182 - 192
  • [45] Non-invasive fractional flow reserve estimation in coronary arteries using angiographic images
    Edrisnia, Hadis
    Sarkhosh, Mohammad Hossein
    Mohebbi, Bahram
    Parhizgar, Seyed Ehsan
    Alimohammadi, Mona
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [46] Non-invasive Investigations of a Wall Painting using Optical Coherence Tomography and Hyperspectral Imaging
    Liang, Haida
    Lange, Rebecca
    Howard, Helen
    Spooner, Jane
    O3A: OPTICS FOR ARTS, ARCHITECTURE, AND ARCHAEOLOGY III, 2011, 8084
  • [47] Non-invasive evaluation of testicular torsion using ultrasound shear wave elastography: an experimental study
    Lin, Yunyong
    Lu, Wenjie
    Li, Guojing
    Mao, Lin
    Ouyang, Liangyan
    Zhu, Zhimin
    Chen, Shiyan
    Liang, Peixian
    Jin, Haowei
    Gao, Linlin
    Liang, Jianjing
    Qiu, Shaodong
    Chen, Fei
    ULTRASONOGRAPHY, 2024, 43 (02) : 98 - 109
  • [48] Non-invasive method for the aortic blood pressure waveform estimation using the measured radial EBI
    Krivoshei, Andrei
    Lamp, Juergen
    Min, Mart
    Uuetoa, Tiina
    Uuetoa, Hasso
    Annus, Paul
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [49] Left Ventricular Radial and Circumferential Wall Motion Analysis in Horses Using Strain, Strain Rate, and Displacement by 2D Speckle Tracking
    Schwarzwald, C. C.
    Schober, K. E.
    Berli, A. -S J.
    Bonagura, J. D.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2009, 23 (04) : 890 - 900
  • [50] Non-invasive real-time imaging of atherosclerosis in mice using ultrasound biomicroscopy
    Gan, Li-ming
    Gronros, Julia
    Hagg, Ulrika
    Wikstrom, Johannes
    Theodoropoulos, Catherine
    Friberg, Peter
    Fritsche-Danielson, Regina
    ATHEROSCLEROSIS, 2007, 190 (02) : 313 - 320