NON-INVASIVE VASCULAR RADIAL/CIRCUMFERENTIAL STRAIN IMAGING AND WALL SHEAR RATE ESTIMATION USING VIDEO IMAGES OF DIAGNOSTIC ULTRASOUND

被引:16
|
作者
Wan, Jinjin [1 ]
He, Fangli [1 ]
Zhao, Yongfeng [2 ]
Zhang, Hongmei [1 ]
Zhou, Xiaodong [2 ]
Wan, Mingxi [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Life Sci & Technol, Dept Biomed Engn, Key Lab Biomed Informat Engn,Minist Educ, Xian 710049, Peoples R China
[2] Fourth Mil Med Univ, Xijing Hosp, Dept Ultrasound, Xian 710032, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2014年 / 40卷 / 03期
基金
中国国家自然科学基金;
关键词
Carotid; Atherosclerosis; Routine screening; Gray-scale correction; Radial strain; Circumferential strain; Transverse Doppler; Wall shear rate; IN-VIVO; INTRAVASCULAR ULTRASOUND; MYOCARDIAL ELASTOGRAPHY; BLOOD-FLOW; ELASTICITY; ATHEROSCLEROSIS; ARTERY; DISPLACEMENT; STRESS; RESOLUTION;
D O I
10.1016/j.ultrasmedbio.2013.10.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of this work was to develop a convenient method for radial/circumferential strain imaging and shear rate estimation that could be used as a supplement to the current routine screening for carotid atherosclerosis using video images of diagnostic ultrasound. A reflection model-based correction for gray-scale non-uniform distribution was applied to B-mode video images before strain estimation to improve the accuracy of radial/circumferential strain imaging when applied to vessel transverse cross sections. The incremental and cumulative radial/circumferential strain images can then be calculated based on the displacement field between consecutive B-mode images. Finally, the transverse Doppler spectra acquired at different depths along the vessel diameter were used to construct the spatially matched instantaneous wall shear values in a cardiac cycle. Vessel phantom simulation results revealed that the signal-to-noise ratio and contrast-to-noise ratio of the radial and circumferential strain images were increased by 2.8 and 5.9 dB and by 2.3 and 4.4 dB, respectively, after non-uniform correction. Preliminary results for 17 patients indicated that the accuracy of radial/circumferential strain images was improved in the lateral direction after non-uniform correction. The peak-to-peak value of incremental strain and the maximum cumulative strain for calcified plaques are evidently lower than those for other plaque types, and the echolucent plaques had higher values, on average, than the mixed plaques. Moreover, low oscillating wall shear rate values, found near the plaque and stenosis regions, are closely related to plaque formation. In conclusion, the method described can provide additional valuable results as a supplement to the current routine ultrasound examination for carotid atherosclerosis and, therefore, has significant potential as a feasible screening method for atherosclerosis diagnosis in the future. (E-mail:mxwan@mail.xjtu.edu.cn) (C) 2014 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:622 / 636
页数:15
相关论文
共 50 条
  • [21] Non-invasive Estimation of Pressure Gradients in Pulsatile Flow using Ultrasound
    Olesen, Jacob Bjerring
    Hoyos, Carlos Armando Villagomez
    Traberg, Marie Sand
    Jensen, Jorgen Arendt
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2257 - 2260
  • [22] Non-invasive estimation of blood pressure using ultrasound contrast agents
    Andersen, Klaus Scheldrup
    Jensen, Jorgen Arendt
    INTERNATIONAL CONGRESS ON ULTRASONICS, PROCEEDINGS, 2010, 3 (01): : 245 - 253
  • [23] Direct ultrasound measurement of longitudinal, circumferential, and radial strain using 2-dimensional strain imaging in normal adults
    Hurlburt, Heather M.
    Aurigemma, Gerard P.
    Hill, Jeffrey C.
    Narayanan, Arumugam
    Gaasch, William H.
    Vinch, Craig S.
    Meyer, Theo E.
    Tighe, Dennis A.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (07): : 723 - 731
  • [24] Respiratory Rate Estimation by a Non-invasive Optical Method Based on Video Image Processing
    Hurtado-Otalora, C. A.
    Pulgarin-Giraldo, J. D.
    Gonzalez-Vargas, A. M.
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 242 - 251
  • [25] Non-invasive evaluation of Poisson's ratio of arterial wall using ultrasound
    Hasegawa, H
    Kanai, H
    Chubachi, N
    Koiwa, Y
    ELECTRONICS LETTERS, 1997, 33 (04) : 340 - 342
  • [26] Re-evaluating the Appropriateness of Non-invasive Arterial Vascular Imaging and Diagnostic Modalities
    Misher J.M.
    Galmer A.M.
    Weinberg M.W.
    Pellerito J.S.
    Lau J.F.
    Current Treatment Options in Cardiovascular Medicine, 2017, 19 (8)
  • [27] A non-invasive study of alterations of the carotid artery with age using ultrasound images
    Balasundaram, Jayanthi K.
    Banu, R. S. D. Wahida
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (09) : 767 - 772
  • [28] A non-invasive study of alterations of the carotid artery with age using ultrasound images
    Jayanthi K. Balasundaram
    R. S. D. Wahida Banu
    Medical and Biological Engineering and Computing, 2006, 44 : 767 - 772
  • [29] Non-invasive Intravascular Pressure Gradient Estimation using Synthetic Aperture Ultrasound
    Haslund, Lars Emil
    Kurukuladithya, Shamal Surain
    Ariyasinghe, Malmindi
    Stuart, Matthias Bo
    Traberg, Marie Sand
    Jensen, Jorgen Arendt
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [30] Optimization of the Strain Tensor Estimation For Cross Sectional Non-Invasive Elastography of the Carotid using Plane Wave Imaging
    Poree, Jonathan
    Garcia, Damien
    Ohayon, Jacques
    Cloutier, Guy
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012,