NON-INVASIVE VASCULAR RADIAL/CIRCUMFERENTIAL STRAIN IMAGING AND WALL SHEAR RATE ESTIMATION USING VIDEO IMAGES OF DIAGNOSTIC ULTRASOUND

被引:16
|
作者
Wan, Jinjin [1 ]
He, Fangli [1 ]
Zhao, Yongfeng [2 ]
Zhang, Hongmei [1 ]
Zhou, Xiaodong [2 ]
Wan, Mingxi [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Life Sci & Technol, Dept Biomed Engn, Key Lab Biomed Informat Engn,Minist Educ, Xian 710049, Peoples R China
[2] Fourth Mil Med Univ, Xijing Hosp, Dept Ultrasound, Xian 710032, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2014年 / 40卷 / 03期
基金
中国国家自然科学基金;
关键词
Carotid; Atherosclerosis; Routine screening; Gray-scale correction; Radial strain; Circumferential strain; Transverse Doppler; Wall shear rate; IN-VIVO; INTRAVASCULAR ULTRASOUND; MYOCARDIAL ELASTOGRAPHY; BLOOD-FLOW; ELASTICITY; ATHEROSCLEROSIS; ARTERY; DISPLACEMENT; STRESS; RESOLUTION;
D O I
10.1016/j.ultrasmedbio.2013.10.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of this work was to develop a convenient method for radial/circumferential strain imaging and shear rate estimation that could be used as a supplement to the current routine screening for carotid atherosclerosis using video images of diagnostic ultrasound. A reflection model-based correction for gray-scale non-uniform distribution was applied to B-mode video images before strain estimation to improve the accuracy of radial/circumferential strain imaging when applied to vessel transverse cross sections. The incremental and cumulative radial/circumferential strain images can then be calculated based on the displacement field between consecutive B-mode images. Finally, the transverse Doppler spectra acquired at different depths along the vessel diameter were used to construct the spatially matched instantaneous wall shear values in a cardiac cycle. Vessel phantom simulation results revealed that the signal-to-noise ratio and contrast-to-noise ratio of the radial and circumferential strain images were increased by 2.8 and 5.9 dB and by 2.3 and 4.4 dB, respectively, after non-uniform correction. Preliminary results for 17 patients indicated that the accuracy of radial/circumferential strain images was improved in the lateral direction after non-uniform correction. The peak-to-peak value of incremental strain and the maximum cumulative strain for calcified plaques are evidently lower than those for other plaque types, and the echolucent plaques had higher values, on average, than the mixed plaques. Moreover, low oscillating wall shear rate values, found near the plaque and stenosis regions, are closely related to plaque formation. In conclusion, the method described can provide additional valuable results as a supplement to the current routine ultrasound examination for carotid atherosclerosis and, therefore, has significant potential as a feasible screening method for atherosclerosis diagnosis in the future. (E-mail:mxwan@mail.xjtu.edu.cn) (C) 2014 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:622 / 636
页数:15
相关论文
共 50 条
  • [1] A global strain estimation algorithm for non-invasive vascular ultrasound elastography
    Li, Hongliang
    Poree, Jonathan
    Chayer, Boris
    Cardinal, Marie-Helene Roy
    Cloutier, Guy
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 2210 - 2213
  • [2] Robust estimation of arterial strain from non-invasive carotid ultrasound images
    Chan, RC
    Karl, WC
    Lees, RS
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1313 - 1314
  • [3] Non-invasive Vascular Ultrasound Strain Imaging: Different Arteries, Different Approaches
    Hansen, H. H. G.
    Lopata, R. G. P.
    Holewijn, S.
    Truijers, M.
    de Korte, C. L.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 298 - 302
  • [4] IN VIVO VASCULAR WALL SHEAR RATE AND CIRCUMFERENTIAL STRAIN OF RENAL DISEASE PATIENTS
    Park, Dae Woo
    Kruger, Grant H.
    Rubin, Jonathan M.
    Hamilton, James
    Gottschalk, Paul
    Dodde, Robert E.
    Shih, Albert J.
    Weitzel, William F.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (02): : 241 - 252
  • [5] Non-Invasive Quantitative Imaging of arterial wall elasticity using Supersonic Shear Imaging
    Couade, Mathieu
    Pernot, Mathieu
    Tanter, Mickael
    Prada, Claire
    Messas, Emmanuel
    Fink, Mathias
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 946 - +
  • [6] Non-invasive quantitative Imaging of arterial wall elasticity using supersonic shear imaging
    Couade, M.
    Pernot, M.
    Tanter, M.
    Prada, C.
    Perri, C.
    Emmerich, J.
    Fink, M.
    Messas, E.
    EUROPEAN HEART JOURNAL, 2009, 30 : 49 - 49
  • [7] NON-INVASIVE ESTIMATION OF TEMPERATURE USING DIAGNOSTIC ULTRASOUND DURING HIFU THERAPY
    Georg, O.
    Wilkens, V.
    PROCEEDINGS FROM THE 13TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2017, 1816
  • [8] Quantitative analysis and applications of non-invasive temperature estimation using diagnostic ultrasound
    Simon, C
    VanBaren, P
    Ebbini, E
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 1319 - 1322
  • [9] Direct Estimation of Carotid Artery Wall Shear Strain Parameters Using Autocorrelation of High Frame Rate Ultrasound Images
    Adibi, Yasaman
    Divani, Afshin
    Ebbini, Emad
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1810 - 1813
  • [10] Non-invasive temperature imaging using ultrasound echo strain: Preliminary simulations
    Bamber, JC
    Meaney, P
    Doyley, MM
    Clarke, RL
    ter Haar, GR
    ACOUSTICAL IMAGING, VOL 23, 1997, 23 : 25 - 33