Reduction of Detection Volume in Total Internal Reflection Fluorescence Microscopy Using Graphene

被引:0
|
作者
Uddin, Shiekh Zia [1 ]
Talukder, Muhammad Anisuzzaman [1 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Elect & Elect Engn, Dhaka 1205, Bangladesh
关键词
Total Internal Reflection Fluorescence Microscopy; Graphene; Detection Volume; OPTICS; BIOLOGY; MEDIA;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We show that it is possible to decrease the thickness of the detection volume of total internal reflection fluorescence microscopy (TIRFM) by similar to 35% using a graphene layer in the interface between glass and water layers of a typical TIRFM structure without sacrificing the fluorescence intensity. The highly mobile surface bound electrons of a graphene mono-layer quenches the fluorophores that are less than similar to 40 nm away from it. The decreased detection volume using the proposed structure will increase the resolution of a typical TIRFM technique. We find that the results are qualitatively similar for different incidence angles and polarizations of the excitation field. So, the proposed structure will also find applications in variants of TIRFM techniques, e.g., where incidence angles and polarizations are varied.
引用
收藏
页码:143 / 146
页数:4
相关论文
共 50 条
  • [31] Imaging with total internal reflection fluorescence microscopy for the cell biologist
    Mattheyses, Alexa L.
    Simon, Sanford M.
    Rappoport, Joshua Z.
    JOURNAL OF CELL SCIENCE, 2010, 123 (21) : 3621 - 3628
  • [32] Total internal reflection fluorescence microscopy (TIRFM) in cell biology
    Schneckenburger, H
    CYTOMETRY PART A, 2006, 69A (01) : 46 - 46
  • [33] Total internal reflection fluorescence microscopy in single molecule nanobioscience
    Wazawa, T
    Ueda, M
    MICROSCOPY TECHNIQUES, 2005, 95 : 77 - 106
  • [34] Scanning total internal reflection fluorescence microscopy and its applications
    Chon, JWM
    Gu, M
    BIOMEDICAL APPLICATIONS OF MICRO- AND NANOENGINEERING, 2002, 4937 : 202 - 210
  • [35] Total Internal Reflection Fluorescence (TIRF) Microscopy of Chlamydomonas Flagella
    Engel, Benjamin D.
    Lechtreck, Karl-Ferdinand
    Sakai, Tsuyoshi
    Ikebe, Mitsuo
    Witman, George B.
    Marshall, Wallace F.
    CILIA: MODEL ORGANISMS AND INTRAFLAGELLAR TRANSPORT, 2009, 93 : 157 - +
  • [36] Single molecule imaging of BK channels using total internal reflection fluorescence microscopy
    Ikeda, Chikako
    Yamamura, Hisao
    Ohya, Susumu
    Imaizumi, Yuji
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2007, 127 : 169 - 172
  • [37] Super-resolved total internal reflection fluorescence microscopy using random illuminations
    Affannoukoue, Kevin
    Labouesse, Simon
    Maire, Guillaume
    Gallais, Laurent
    Savatier, Julien
    Allain, Marc
    Rasedujjaman, Md
    Legoff, Loic
    Idier, Jerome
    Poincloux, Renaud
    Pelletier, Florence
    Leterrier, Christophe
    Mangeat, Thomas
    Sentenac, Anne
    OPTICA, 2023, 10 (08): : 1009 - 1017
  • [38] Single molecule kinetics using total internal reflection fluorescence microscopy and digital imaging
    Drake, AW
    Thompson, NL
    BIOPHYSICAL JOURNAL, 1997, 72 (02) : TU439 - TU439
  • [39] Structured illumination in total internal reflection fluorescence microscopy using a spatial light modulator
    Fiolka, Reto
    Beck, Markus
    Stemmer, Andreas
    OPTICS LETTERS, 2008, 33 (14) : 1629 - 1631
  • [40] Using Total Internal Reflection Fluorescence Microscopy To Visualize Rhodopsin-Containing Cells
    Keffer, J. L.
    Sabanayagam, C. R.
    Lee, M. E.
    DeLong, E. F.
    Hahn, M. W.
    Maresca, J. A.
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2015, 81 (10) : 3442 - 3450