Reduction of Detection Volume in Total Internal Reflection Fluorescence Microscopy Using Graphene

被引:0
|
作者
Uddin, Shiekh Zia [1 ]
Talukder, Muhammad Anisuzzaman [1 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Elect & Elect Engn, Dhaka 1205, Bangladesh
关键词
Total Internal Reflection Fluorescence Microscopy; Graphene; Detection Volume; OPTICS; BIOLOGY; MEDIA;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We show that it is possible to decrease the thickness of the detection volume of total internal reflection fluorescence microscopy (TIRFM) by similar to 35% using a graphene layer in the interface between glass and water layers of a typical TIRFM structure without sacrificing the fluorescence intensity. The highly mobile surface bound electrons of a graphene mono-layer quenches the fluorophores that are less than similar to 40 nm away from it. The decreased detection volume using the proposed structure will increase the resolution of a typical TIRFM technique. We find that the results are qualitatively similar for different incidence angles and polarizations of the excitation field. So, the proposed structure will also find applications in variants of TIRFM techniques, e.g., where incidence angles and polarizations are varied.
引用
收藏
页码:143 / 146
页数:4
相关论文
共 50 条
  • [21] Imaging stimulated exocytosis with total internal reflection fluorescence microscopy
    Allersma, MW
    Holz, RW
    Axelrod, D
    BIOPHYSICAL JOURNAL, 2002, 82 (01) : 614A - 615A
  • [22] Imaging constitutive exocytosis with total internal reflection fluorescence microscopy
    Schmoranzer, J
    Goulian, M
    Axelrod, D
    Simon, SM
    JOURNAL OF CELL BIOLOGY, 2000, 149 (01): : 23 - 31
  • [23] Practical applications of total internal reflection fluorescence microscopy for nanocatalysis
    Yan, Chengyang
    Mei, Xuanhao
    Gong, Xue
    Xu, Weilin
    INDUSTRIAL CHEMISTRY & MATERIALS, 2024, 2 (01): : 85 - 99
  • [24] Total internal reflection fluorescence microscopy: Applications to cell biology
    Axelrod, D
    Sund, SE
    Johns, LM
    Holz, RW
    JOURNAL OF GENERAL PHYSIOLOGY, 1999, 114 (01): : 4A - 4A
  • [25] Sequential exocytosis detected by total internal reflection fluorescence microscopy
    Tran, Samuel
    Huet, Sebastien
    Fanget, Isabelle
    Cribier, Sophie
    Henry, Jean-Pierre
    Karatekin, Erdem
    BIOPHYSICAL JOURNAL, 2007, : 171A - 171A
  • [26] Combined scanning probe and total internal reflection fluorescence microscopy
    Oreopoulos, John
    Yip, Christopher M.
    METHODS, 2008, 46 (01) : 2 - 10
  • [27] Around-the-objective total internal reflection fluorescence microscopy
    Burghardt, Thomas P.
    Hipp, Andrew D.
    Ajtai, Katalin
    APPLIED OPTICS, 2009, 48 (32) : 6120 - 6131
  • [28] Extending The Resolution In Total Internal Reflection Fluorescence (TIRF) Microscopy
    Fiolka, Reto P.
    Stemmer, Andreas
    BIOPHYSICAL JOURNAL, 2009, 96 (03) : 636A - 636A
  • [29] Transient State Monitoring by Total Internal Reflection Fluorescence Microscopy
    Spielmann, Thiemo
    Blom, Hans
    Geissbuehler, Matthias
    Lasser, Theo
    Widengren, Jerker
    JOURNAL OF PHYSICAL CHEMISTRY B, 2010, 114 (11): : 4035 - 4046
  • [30] Around-the-Objective Total Internal Reflection Fluorescence Microscopy
    Burghardt, Thomas P.
    Hipp, Andrew D.
    Ajtai, Katalin
    BIOPHYSICAL JOURNAL, 2010, 98 (03) : 177A - 178A