EFFECT OF MLC LEAF WIDTH AND PTV MARGIN ON THE TREATMENT PLANNING OF INTENSITY-MODULATED STEREOTACTIC RADIOSURGERY (IMSRS) OR RADIOTHERAPY (IMSRT)

被引:18
|
作者
Chang, Jenghwa [1 ]
Yenice, Kamil M.
Jiang, Kailiu
Hunt, Margie
Narayana, Ashwatha
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
Stereotactic radiosurgery; Intensity modulation; Micro-multileaf collimator; Leaf width; PTV margin; RADIATION-THERAPY; COLLIMATOR; FRAME; SYSTEM; IMPACT;
D O I
10.1016/j.meddos.2008.06.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We studied the effect of MLC (multileaf collimator) leaf width and PTV (planning target volume) margin on treatment planning of intensity modulated stereotactic racdiosurgery (IMSRS) or radiotherapy (IMSRT). Twelve patients previously treated with IMSRS/IMSRT were retrospectively planned with 5- and 3-mm MLC leaf widths and 3- and 2-mm PTV margins using the already contoured clinical target volume and critical structures. The same beam arrangement, planning parameters, and optimization method were used in each of the 4 plans for a given patient. Each plan was normalized so that the prescription dose covered at least 99% of the PTV. Plan indices -D(mean) (mean dose), conformity index (CI), V(70) (volume receiving >= 70% of the prescription dose), and V(50) (volume receiving >= 50% of the prescription dose) - were calculated from the dose-volume histograms (DVHs) of the PTV, normal tissue, and organs at risk (OARs). Hypothesis testing was performed on the mean ratios of plan indices to determine the statistical significance of the relative differences. The PTV was well covered for all plans, as no significant differences were observed for D(95), V(95), D(max), D(min), and D(mean) of the PTV. The irradiated volume was similar to 23% smaller when 2-mm instead of 3-mm PTV margin was used, but it was only reduced by similar to 6% when the MLC leaf width was reduced from 5 mm to 3 mm. For normal tissue and brainstem, V(70), V(50), and D(mean) were reduced more effectively by a decrease in MLC width, while D(mean) of optic nerve and chiasm were more sensitive to a change in PTV margin. The DVH statistics for the PTV and normal structures from the treatment plan with 5-mm MLC and 2-mm PTV margin were equal to those with 3-mm MLC and 3-mm PTV margin. PTV margin reduction is more effective in sparing the normal tissue and OARs than a reduction in MLC leaf width. For IMSRS, where highly accurate setup and small PTV margins are routinely employed, the use of 5-mm MLC is therefore less desirable. (C) 2009 American Association of Medical Dosimetrists.
引用
收藏
页码:110 / 116
页数:7
相关论文
共 50 条
  • [41] The effect of multileaf collimator leaf width on the radiosurgery planning for spine lesion treatment in terms of the modulated techniques and target complexity
    Soo-Min Chae
    Gi Woong Lee
    Seok Hyun Son
    Radiation Oncology, 9
  • [42] The effect of multileaf collimator leaf width on the radiosurgery planning for spine lesion treatment in terms of the modulated techniques and target complexity
    Chae, Soo-Min
    Lee, Gi Woong
    Son, Seok Hyun
    RADIATION ONCOLOGY, 2014, 9
  • [43] Intensity-modulated radiotherapy of nasopharyngeal carcinoma: a comparative treatment planning study of photons and protons
    Zahra Taheri-Kadkhoda
    Thomas Björk-Eriksson
    Simeon Nill
    Jan J Wilkens
    Uwe Oelfke
    Karl-Axel Johansson
    Peter E Huber
    Marc W Münter
    Radiation Oncology, 3
  • [44] Inverse radiotherapy treatment planning for intensity-modulated beams using the linear programming method
    Hilbig, M
    Hanne, R
    Kneschaurek, P
    Wilkens, J
    Zimmermann, F
    Schweikard, A
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 477 - 482
  • [45] Intensity-modulated radiotherapy of nasopharyngeal carcinoma: a comparative treatment planning study of photons and protons
    Taheri-Kadkhoda, Zahra
    Bjork-Eriksson, Thomas
    Nill, Simeon
    Wilkens, Jan J.
    Oelfke, Uwe
    Johansson, Karl-Axel
    Huber, Peter E.
    Muenter, Marc W.
    RADIATION ONCOLOGY, 2008, 3 (1)
  • [46] Performance Comparison of Four Commercial Treatment Planning Systems Applied to Intensity-Modulated Radiotherapy
    Cao, Y.
    Li, R.
    Chi, Z.
    MEDICAL PHYSICS, 2014, 41 (06) : 367 - 368
  • [47] Concave Approximations of Target Volume Dose Metrics for Intensity-Modulated Radiotherapy Treatment Planning
    Xie, Y.
    Chen, Y.
    Wickerhauser, M.
    Deasy, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 312 - 312
  • [48] A comparison of forward and inverse treatment planning for intensity-modulated radiotherapy of head and neck cancer
    Bär, W
    Schwarz, M
    Alber, M
    Bos, LJ
    Mijnheer, BJ
    Rasch, C
    Schneider, C
    Nüsslin, F
    Damen, EMF
    RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) : 251 - 258
  • [49] Intensity-modulated Radiotherapy Planning at Mediastinal Lymphoma Treatment: Sandglass, Rainbow and Butterfly Techniques
    Yucel, Serap
    Gural, Zeynep
    Agaoglu, Fulya
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (01): : 37 - 40
  • [50] Treatment Planning Comparison for Carbon Ion Radiotherapy, Proton Therapy and Intensity-modulated Radiotherapy for Spinal Sarcoma
    Matsumoto, Keiji
    Nakamura, Katsumasa
    Shioyama, Yoshiyuki
    Sasaki, Tomonari
    Ohga, Saiji
    Yamaguchi, Toshihiro
    Yoshitake, Tadamasa
    Asai, Kaori
    Kakiuchi, Genyu
    Honda, Hiroshi
    ANTICANCER RESEARCH, 2015, 35 (07) : 4083 - 4089