EFFECT OF MLC LEAF WIDTH AND PTV MARGIN ON THE TREATMENT PLANNING OF INTENSITY-MODULATED STEREOTACTIC RADIOSURGERY (IMSRS) OR RADIOTHERAPY (IMSRT)

被引:18
|
作者
Chang, Jenghwa [1 ]
Yenice, Kamil M.
Jiang, Kailiu
Hunt, Margie
Narayana, Ashwatha
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
Stereotactic radiosurgery; Intensity modulation; Micro-multileaf collimator; Leaf width; PTV margin; RADIATION-THERAPY; COLLIMATOR; FRAME; SYSTEM; IMPACT;
D O I
10.1016/j.meddos.2008.06.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We studied the effect of MLC (multileaf collimator) leaf width and PTV (planning target volume) margin on treatment planning of intensity modulated stereotactic racdiosurgery (IMSRS) or radiotherapy (IMSRT). Twelve patients previously treated with IMSRS/IMSRT were retrospectively planned with 5- and 3-mm MLC leaf widths and 3- and 2-mm PTV margins using the already contoured clinical target volume and critical structures. The same beam arrangement, planning parameters, and optimization method were used in each of the 4 plans for a given patient. Each plan was normalized so that the prescription dose covered at least 99% of the PTV. Plan indices -D(mean) (mean dose), conformity index (CI), V(70) (volume receiving >= 70% of the prescription dose), and V(50) (volume receiving >= 50% of the prescription dose) - were calculated from the dose-volume histograms (DVHs) of the PTV, normal tissue, and organs at risk (OARs). Hypothesis testing was performed on the mean ratios of plan indices to determine the statistical significance of the relative differences. The PTV was well covered for all plans, as no significant differences were observed for D(95), V(95), D(max), D(min), and D(mean) of the PTV. The irradiated volume was similar to 23% smaller when 2-mm instead of 3-mm PTV margin was used, but it was only reduced by similar to 6% when the MLC leaf width was reduced from 5 mm to 3 mm. For normal tissue and brainstem, V(70), V(50), and D(mean) were reduced more effectively by a decrease in MLC width, while D(mean) of optic nerve and chiasm were more sensitive to a change in PTV margin. The DVH statistics for the PTV and normal structures from the treatment plan with 5-mm MLC and 2-mm PTV margin were equal to those with 3-mm MLC and 3-mm PTV margin. PTV margin reduction is more effective in sparing the normal tissue and OARs than a reduction in MLC leaf width. For IMSRS, where highly accurate setup and small PTV margins are routinely employed, the use of 5-mm MLC is therefore less desirable. (C) 2009 American Association of Medical Dosimetrists.
引用
收藏
页码:110 / 116
页数:7
相关论文
共 50 条
  • [21] Dosimetric effects of multileaf collimator leaf width on intensity-modulated radiotherapy for head and neck cancer
    Ju, S. G.
    Hong, C. S.
    Kim, M. K.
    Kim, J. I.
    Suh, T. S.
    Han, Y. I.
    Ahn, Y. C.
    Choi, D. H.
    Nam, H. R.
    Park, H. C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S156 - S157
  • [22] IMPACTS OF MULTILEAF COLLIMATORS LEAF WIDTH ON INTENSITY-MODULATED RADIOTHERAPY PLANNING FOR NASOPHARYNGEAL CARCINOMA: ANALYSIS OF TWO COMMERCIAL ELEKTA DEVICES
    Wang, Shichao
    Gong, Youling
    Xu, Qingfeng
    Bai, Sen
    Lu, You
    Jiang, Qingfeng
    Chen, Nianyong
    MEDICAL DOSIMETRY, 2011, 36 (02) : 153 - 159
  • [23] Intensity-modulated stereotactic radiotherapy vs. stereotactic conformal radiotherapy for the treatment of meningioma located predominantly in the skull base
    Baumert, BG
    Norton, IA
    Davis, JB
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (02): : 580 - 592
  • [24] Adverse effect of a distended rectum in intensity-modulated radiotherapy (IMRT) treatment planning of prostate cancer
    Guckenberger, M
    Pohl, F
    Baier, K
    Meyer, J
    Vordermark, D
    Flentje, M
    RADIOTHERAPY AND ONCOLOGY, 2006, 79 (01) : 59 - 64
  • [25] Intensity-modulated stereotactic radiotherapy for the treatment of medically inoperable patients with NSCLC stage I
    Laechelti, Stephan
    Alber, Markus
    Soehn, Matthias
    Bamberg, Michael
    Steger, Volker
    Weinmann, Martin
    ONCOLOGY REPORTS, 2012, 28 (04) : 1309 - 1314
  • [26] The Effect of Multileaf Collimator Leaf Width on the Quality of Volumetric-Modulated Arc Therapy Stereotactic Radiosurgery Treatment Plans
    Laoui, S.
    Kuo, J. V.
    Al-Ghazi, M.
    Roa, D. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E682 - E683
  • [27] Multiplan treatment-planning framework: A paradigm shift for intensity-modulated radiotherapy
    Meyer, Robert R.
    Zhang, Hao H.
    Goadrich, Laura
    Nazareth, Daryl P.
    Shi, Leyuan
    D'Souza, Warren D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (04): : 1178 - 1189
  • [28] An Exact Method for the Minimum Cardinality Problem in the Treatment Planning of Intensity-Modulated Radiotherapy
    Ernst, Andreas T.
    Mak, Vicky H.
    Mason, Luke R.
    INFORMS JOURNAL ON COMPUTING, 2009, 21 (04) : 562 - 574
  • [29] Underestimation of low-dose radiation in treatment planning of intensity-modulated radiotherapy
    Jang, Si Young
    Liu, H. Helen
    Mohan, Radhe
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (05): : 1537 - 1546
  • [30] A genetic algorithm approach to the inverse problem of treatment planning for intensity-modulated radiotherapy
    Ahmad, Sabbir U.
    Bergen, Stuart W. A.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2010, 5 (03) : 189 - 195