Evaluation of Biomechanically Corrected Intraocular Pressure Measurements in Keratoconus and Forme Fruste Keratoconus

被引:7
|
作者
Nishida, Tomoya [1 ]
Kojima, Takashi [1 ,2 ]
Kataoka, Takahiro [1 ]
Isogai, Naoki [1 ]
Yoshida, Yoko [1 ]
Nakamura, Tomoaki [1 ]
机构
[1] Nagoya Eye Clin, Nagoya, Aichi, Japan
[2] Keio Univ, Dept Ophthalmol, Sch Med, Tokyo, Japan
关键词
Biomechanically corrected intraocular pressure; Corvis ST® Forme fruste keratoconus; Keratoconus; Scheimpflug camera; TRANSEPITHELIAL PHOTOREFRACTIVE KERATECTOMY; CORNEAL RESPONSE PARAMETERS; APPLANATION TONOMETRY; CROSS-LINKING; THICKNESS; ANALYZER; HEALTHY;
D O I
10.1159/000506839
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction: Although biomechanically corrected intraocular pressure (bIOP) is available, the effectiveness of intraocular pressure (IOP) correction in keratoconus and forme fruste keratoconus (FFK) eyes has not been investigated. Objective: Evaluation of bIOP measurements in eyes with keratoconus and FFK. Methods: Forty-two eyes in 21 patients with keratoconus in one eye and FFK in the fellow eye were examined (KC/FFK group; mean age 24.62 +/- 8.6 years; 16 males and 5 females). The control group consisted of 62 eyes in 31 unaffected subjects (mean age 26.26 +/- 3.64 years; 15 males and 16 females). The bIOP was determined using a Scheimpflug-based tonometer (Corvis Scheimpflug Technology [Corvis ST (R)]) after measuring the IOP with a conventional non-contact tonometer (NIOP). The agreement between NIOP and bIOP values was examined using the Bland-Altman plot. The difference between NIOP and bIOP (bIOP correction amount) was compared between keratoconus and FFK eyes. Results: In the control group, there were no significant differences between right and left eyes in both NIOP and bIOP values (p = 0.975 and p = 0.224, respectively). In the KC/FFK group, NIOP values were significantly lower in the keratoconus eyes (9.93 +/- 1.96 mm Hg) than in the FFK eyes (12.23 +/- 3.03 mm Hg; p = 0.0003). There was no significant difference in bIOP values between the right and left eyes of the KC/FFK group (p = 0.168). The bIOP correction amount was significantly increased in keratoconus eyes (3.58 +/- 2.12 mm Hg) compared to in FFK eyes (1.80 +/- 3.32 mm Hg; p = 0.011). Conclusions: For eyes with keratoconus and FFK, the bIOP method is effective to adjust IOP measurements based on corneal biomechanical properties.
引用
收藏
页码:541 / 549
页数:9
相关论文
共 50 条
  • [21] Topography-guided surface ablation for forme fruste keratoconus
    Koller, Tobias
    Iseli, Hans Peter
    Donitzky, Christof
    Papadopoulos, Nikolaos
    Seiler, Theo
    OPHTHALMOLOGY, 2006, 113 (12) : 2198 - 2202
  • [22] One-year follow-up of toric intraocular lens implantation in forme fruste keratoconus
    Navas, Alejandro
    Suarez, Raul
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (11): : 2024 - 2027
  • [23] Evaluation of Total and Corneal Wavefront High Order Aberrations for the Detection of Forme Fruste Keratoconus
    Saad, Alain
    Gatinel, Damien
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (06) : 2978 - 2992
  • [24] Intraocular pressure in keratoconus
    Read, Scott A.
    Collins, Michael J.
    ACTA OPHTHALMOLOGICA, 2011, 89 (04) : 358 - 364
  • [25] Comparison of Dual Scheimpflug imaging parameters in eyes with forme fruste keratoconus, keratoconus and low and high ametropia
    Henriquez, Maria
    Izquierdo, Luis
    Moreyra, Harumi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [26] Diagnostic Value of Corneal Epithelial and Stromal Thickness Distribution Profiles in Forme Fruste Keratoconus and Subclinical Keratoconus
    Toprak, Ibrahim
    Vega, Alfredo
    Alio del Barrio, Jorge L.
    Espla, Elias
    Cavas, Francisco
    Alio, Jorge L.
    CORNEA, 2021, 40 (01) : 61 - 72
  • [27] Combined corneal biomechanical and tomographical indices in subclinical and forme fruste keratoconus
    Ganesh, Meghna
    Arora, Ritu
    Titiyal, Jeewan S.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (09)
  • [28] Enhanced Combined Tomography and Biomechanics Data for Distinguishing Forme Fruste Keratoconus
    Luz, Allan
    Lopes, Bernardo
    Hallahan, Katie M.
    Valbon, Bruno
    Ramos, Isaac
    Faria-Correia, Fernando
    Schor, Paulo
    Dupps, William J., Jr.
    Ambrosio, Renato, Jr.
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (07) : 479 - +
  • [29] Evidence of corneal ectasia susceptibility: a new definition of forme fruste keratoconus
    Koh, Shizuka
    Ambrosio, Renato, Jr.
    Maeda, Naoyuki
    Nishida, Kohji
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (11): : 1570 - 1572
  • [30] Corneal biomechanical properties and anterior segment parameters in forme fruste keratoconus
    Kozobolis, Vassilios
    Sideroudi, Haris
    Giarmoukakis, Athanassios
    Gkika, Maria
    Labiris, Georgios
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (06) : 920 - 930