Molecular weight cut-off determination of organic solvent nanofiltration membranes using poly(propylene glycol)

被引:34
|
作者
Davey, Christopher John [1 ,2 ]
Low, Ze-Xian [2 ,3 ]
Wirawan, Remigius H. [1 ]
Patterson, Darrell Alec [1 ,2 ,3 ]
机构
[1] Univ Bath, Ctr Sustainable Chem Technol, Bath BA2 7AY, Avon, England
[2] Univ Bath, Dept Chem Engn, Bath BA2 7AY, Avon, England
[3] Univ Bath, Ctr Adv Separat Engn, Bath BA2 7AY, Avon, England
基金
欧洲研究理事会; 英国工程与自然科学研究理事会;
关键词
Molecular weight cut-off (MWCO); Organic solvent nanofiltration (OSN); Solvent Resistant Nanofiltration (SRNF); Polypropylene glycol) (PPG); Polypropylene oxide) (PPO); Reverse phase high-performance liquid chromatography (HPLC); Evaporative light scattering detection (ELSD); Membranes; RESISTANT NANOFILTRATION; PERFORMANCE; SEPARATION; REJECTION; TRANSPORT; POLARITY;
D O I
10.1016/j.memsci.2016.12.038
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A new method for determining the molecular weight cut-off (MWCO) of an organic solvent nanofiltration (OSN) membrane has been developed utilising poly(propylene glycol) (PPG) oligomers. This new MWCO method overcomes the limitations of the currently popular methods: namely the high molecule cost in the popular polystyrene method, the Donnan Exclusion effects when using dye molecules and the solvent compatibility and HPLC separation resolution limitations of the lesser used poly(ethylene glycol) (PEG) method. A new reverse phase high-performance liquid chromatography separation with evaporative light scattering detection (ELSD) allows the concentration of each oligomer of PPG to be accurately determined and from this the MWCO curves are constructed. The method has a high resolution (size increment of 58 g mol(-1) corresponding to the OCH(CH3)CH2 structural unit) and can be used in polar, polar aprotic, and non-polar solvents. The accuracy of the method has been demonstrated in three different solvents (methanol, acetone, and toluene) and 5 different OSN membranes (DuraMem (R) 150, 200, 500, PuraMem (R) 280 and StarMem (TM) 240). Other advantages include; oligomers of PPG are cheap and widely available, can probe a wide range of MWCO and provide high resolution MWCO curves. Consequently, it is proposed that this method be adopted as a new standard MWCO test for OSN membranes.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 50 条
  • [22] Study on molecular weight cut-off of the anaerobic ultrafiltration membrane bioreactor
    He, Yiliang
    Li, Chunjie
    Wu, Zhichao
    Gu, Guowei
    Zhongguo Jishui Paishui/China Water & Wastewater, 1999, 15 (09): : 10 - 12
  • [23] Preparation method of standard molecules for the precise estimation of molecular weight cut-off of membranes by gel permeation chromatography
    Chung, Youngkun
    Kim, Yeo-Jin
    Kim, Jeong F.
    Lee, Mi-Young
    Nam, Seung-Eun
    Kang, Seoktae
    DESALINATION AND WATER TREATMENT, 2020, 180 : 74 - 79
  • [24] An Efficient Method to Determine Membrane Molecular Weight Cut-Off Using Fluorescent Silica Nanoparticles
    Fadel, Mariam
    Wyart, Yvan
    Moulin, Philippe
    MEMBRANES, 2020, 10 (10) : 1 - 14
  • [25] A molecular simulation protocol for swelling and organic solvent nanofiltration of polymer membranes
    Liu, Jie
    Xu, Qisong
    Jiang, Jianwen
    JOURNAL OF MEMBRANE SCIENCE, 2019, 573 : 639 - 646
  • [26] Organic solvent resistant poly(ether-ether-ketone) nanofiltration membranes
    Burgal, Joao da Silva
    Peeva, Ludmila G.
    Kumbharkar, Santosh
    Livingston, Andrew
    JOURNAL OF MEMBRANE SCIENCE, 2015, 479 : 105 - 116
  • [27] Nanotechnological method to control the molecular weight cut-off and/or pore diameter of organic-inorganic composite membrane
    Okazaki, I
    Ohya, H
    Semenova, SI
    Kikuchi, S
    Aihara, M
    Negishi, Y
    JOURNAL OF MEMBRANE SCIENCE, 1998, 141 (01) : 65 - 74
  • [28] FULLERENOL-POLYAMIDE THIN FILM COMPOSITE HOLLOW FIBER MEMBRANES FOR LOW MOLECULAR WEIGHT CUT-OFF ULTRAFILTRATION
    Bildyukevich, A., V
    Plisko, T., V
    Liubimova, A. S.
    Penkova, A., V
    Dmitrenko, M. E.
    DOKLADY NATSIONALNOI AKADEMII NAUK BELARUSI, 2018, 62 (02): : 185 - 192
  • [29] Atomic force microscopy characterization of ultrafiltration membranes: correspondence between surface pore dimensions and molecular weight cut-off
    Bowen, WR
    Doneva, TA
    SURFACE AND INTERFACE ANALYSIS, 2000, 29 (08) : 544 - +
  • [30] Fluorescence imaging of macromolecule transport in high molecular weight cut-off microdialysis
    Jiangtao Chu
    Vitali Koudriavtsev
    Klas Hjort
    Andreas P. Dahlin
    Analytical and Bioanalytical Chemistry, 2014, 406 : 7601 - 7609