Fluorescence imaging of macromolecule transport in high molecular weight cut-off microdialysis

被引:0
|
作者
Jiangtao Chu
Vitali Koudriavtsev
Klas Hjort
Andreas P. Dahlin
机构
[1] Uppsala University,Department of Engineering Sciences
来源
关键词
Microdialysis; High molecular weight cut-off; Membrane; Fluorescence; Imaging; FITC; Dextran;
D O I
暂无
中图分类号
学科分类号
摘要
When microdialysis (MD) membrane exceeds molecular weight cut-off (MWCO) of 100 kDa, the fluid mechanics are in the ultrafiltration regime. Consequently, fluidic mass transport of macromolecules in the perfusate over the membrane may reduce the biological relevance of the sampling and cause an inflammatory response in the test subject. Therefore, a method to investigate the molecular transport of high MWCO MD is presented. An in vitro test chamber was fabricated to facilitate the fluorescent imaging of the MD sampling process, using fluoresceinylisothiocyanate (FITC) dextran and fluorescence microscopy. Qualitative studies on dextran behavior inside and outside the membrane were performed. Semiquantitative results showed clear dextran leakage from both 40 and 250 kDa dextran when 100 kDa MWCO membranes were used. Dextran 40 kDa leaked out with an order of magnitude higher concentration and the leakage pattern resembled more of a convective flow pattern compared with dextran 250 kDa, where the leakage pattern was more diffusion based. No leakage was observed when dextran 500 kDa was used as a colloid osmotic agent. The results in this study suggest that fluorescence imaging could be used as a method for qualitative and semiquantitative molecular transport and fluid dynamics studies of MD membranes and other hollow fiber catheter membranes.
引用
收藏
页码:7601 / 7609
页数:8
相关论文
共 50 条
  • [1] Fluorescence imaging of macromolecule transport in high molecular weight cut-off microdialysis
    Chu, Jiangtao
    Koudriavtsev, Vitali
    Hjort, Klas
    Dahlin, Andreas P.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (29) : 7601 - 7609
  • [2] Impact of static pressure on transmembrane fluid exchange in high molecular weight cut off microdialysis
    Chu, Jiangtao
    Hjort, Klas
    Larsson, Anders
    Dahlin, Andreas P.
    BIOMEDICAL MICRODEVICES, 2014, 16 (02) : 301 - 310
  • [3] Impact of static pressure on transmembrane fluid exchange in high molecular weight cut off microdialysis
    Jiangtao Chu
    Klas Hjort
    Anders Larsson
    Andreas P. Dahlin
    Biomedical Microdevices, 2014, 16 : 301 - 310
  • [4] In Vivo Microdialysis Method to Collect Large Extracellular Proteins from Brain Interstitial Fluid with High-molecular Weight Cut-off Probes
    Yamada, Kaoru
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (139):
  • [5] A convenient method for the determination of molecular weight cut-off of ultrafiltration membranes
    Cunyu Li
    Yun Ma
    Hongyang Li
    Guoping Peng
    ChineseJournalofChemicalEngineering, 2017, 25 (01) : 62 - 67
  • [6] Study on molecular weight cut-off of the anaerobic ultrafiltration membrane bioreactor
    He, Yiliang
    Li, Chunjie
    Wu, Zhichao
    Gu, Guowei
    Zhongguo Jishui Paishui/China Water & Wastewater, 1999, 15 (09): : 10 - 12
  • [7] A convenient method for the determination of molecular weight cut-off of ultrafiltration membranes
    Li, Cunyu
    Ma, Yun
    Li, Hongyang
    Peng, Guoping
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2017, 25 (01) : 62 - 67
  • [8] A high vacuum cut-off
    Schmitt, OH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1937, 8 : 68 - 69
  • [9] A HIGH VACUUM CUT-OFF
    SERFASS, EJ
    MURACA, RF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1945, 16 (08): : 225 - 225
  • [10] FLUORESCENCE SPECTRA OF SHARP CUT-OFF FILTERS
    FRENCH, CS
    APPLIED OPTICS, 1965, 4 (04): : 514 - &