The impact of patient table on size-specific dose estimate (SSDE)

被引:28
|
作者
Anam, Choirul [1 ,2 ]
Haryanto, Freddy [2 ]
Widita, Rena [2 ]
Arif, Idam [2 ]
Dougherty, Geoff [3 ]
McLean, Donald [4 ]
机构
[1] Diponegoro Univ, Dept Phys, Fac Math & Nat Sci, Semarang 50275, Central Java, Indonesia
[2] Bandung Inst Technol, Dept Phys, Fac Math & Nat Sci, Ganesha 10, Bandung 40132, West Java, Indonesia
[3] CSUCI, Appl Phys & Med Imaging, Camarillo, CA 93012 USA
[4] Canberra Hosp, Med Phys & Radiat Engn, Garran, ACT 2605, Australia
关键词
Water equivalent diameter (D-W); Size-specific dose estimates (SSDE); Volume CT dose index (CTDIVOL); Patient dose; Patient table; ATTENUATION-BASED ESTIMATION; RAY COMPUTED-TOMOGRAPHY; PEDIATRIC CHEST CT; INDEX; IMPLEMENTATION; DIAMETER; MEDICINE; PURPOSE; CANCER; RISKS;
D O I
10.1007/s13246-016-0497-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of parameters water equivalent diameter (D-W) and size-specific dose estimate (SSDE) are becoming increasingly established as a recognised method to relate patient dose from a CT examination to the dose indicator volume CT dose index (CTDIVOL). However, the role of the attenuation due to the patient table in these estimations requires careful consideration and is the subject of this study. The aim of this study is to investigate the impact of a minimal part of the patient table when calculating the D-W and SSDE. We investigated 164 patients who had undergone CT examinations for the pelvis, abdomen, thorax and head. We subsequently calculated D-W and SSDE using two methods: one using a small circular region of interest (ROI) including a minimal part of the patient table and the other using a ROI fitted to the patient border alone. The results showed that the water equivalent diameter calculated with the table included in the ROI (D-W,D- t) is greater, compared to that without the consideration of the patient table (D-W,D- nt), by 1.5-6.2% depending on the anatomy being imaged. On the other hand, the SSDE calculated with inclusion of the patient table (SSDEt) is smaller than otherwise (SSDEnt) by 1.0-5.5% again depending on the anatomy being imaged. The effect of the patient table on D-W and SSDE in the thorax CT examination was statistically significant, but its effect on D-W and SSDE in the other examinations of head, pelvis and abdomen was relatively small and not statistically significant.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 50 条
  • [41] Evaluation of direct point dose estimation based on the distribution of the size-specific dose estimate
    Anam, Choirul
    Sutanto, Heri
    Amilia, Riska
    Marini, Rini
    Barokah, Sinta Nur
    Osman, Noor Diyana
    Dougherty, Geoff
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (04) : 1525 - 1535
  • [42] Variation of size-specific dose estimates (SSDE) of cone-beam CT (CBCT) scans with the scan length
    Abuhaimed, A.
    Martin, C.
    Demirkaya, O.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S907 - S907
  • [43] Influence of Water Equivalent Diameter (Dw) Variability Inside the Scan Area on Size-Specific Dose Estimates (SSDE)
    Abuhaimed, A.
    Martin, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E540 - E540
  • [44] How accurate is size-specific dose estimate in pediatric body CT examinations?
    Karmazyn, Boaz
    Ai, Huisi
    Klahr, Paul
    Ouyang, Fangqian
    Jennings, S. Gregory
    PEDIATRIC RADIOLOGY, 2016, 46 (09) : 1234 - 1240
  • [45] How accurate is size-specific dose estimate in pediatric body CT examinations?
    Boaz Karmazyn
    Huisi Ai
    Paul Klahr
    Fangqian Ouyang
    S. Gregory Jennings
    Pediatric Radiology, 2016, 46 : 1234 - 1240
  • [46] THE SIZE-SPECIFIC DOSE ESTIMATE OF PAEDIATRIC HEAD CT EXAMINATIONS FOR VARIOUS PROTOCOLS
    Fahmi, Arif
    Anam, Choirul
    Ali, Mohd Hanafi
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (04) : 522 - 528
  • [47] Improved Estimates of Trunk and Head CT Radiation Dose: Development of Size-Specific Dose Estimate
    Strauss, Keith J.
    McKenney, Sarah E.
    Brady, Samuel L.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2020, 17 (04) : 560 - 562
  • [48] Dose-Reduced Kidney Stone CT Protocol Optimized with Size-Specific Dose Estimate
    Deng, S.
    Kulkarni, A.
    Harris, N.
    Zimmermann, L.
    Al Helo, R.
    Jordan, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E395 - E395
  • [49] Correlation of Body Mass Index (BMI) and Water Equivalent Diameter (Dw) Used for Size-Specific Dose Estimates (SSDE)
    Abuhaimed, A.
    Martin, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E522 - E522
  • [50] Size-Specific Dose Estimates (SSDE) for Patients Examined with Loss-Dose Lung Cancer Screening Using Different CT Manufacturers
    Barreto, I.
    Quails, N.
    Carranza, C.
    Correa, N.
    Rill, L.
    Arreola, M.
    MEDICAL PHYSICS, 2018, 45 (06) : E600 - E600