The impact of patient table on size-specific dose estimate (SSDE)

被引:28
|
作者
Anam, Choirul [1 ,2 ]
Haryanto, Freddy [2 ]
Widita, Rena [2 ]
Arif, Idam [2 ]
Dougherty, Geoff [3 ]
McLean, Donald [4 ]
机构
[1] Diponegoro Univ, Dept Phys, Fac Math & Nat Sci, Semarang 50275, Central Java, Indonesia
[2] Bandung Inst Technol, Dept Phys, Fac Math & Nat Sci, Ganesha 10, Bandung 40132, West Java, Indonesia
[3] CSUCI, Appl Phys & Med Imaging, Camarillo, CA 93012 USA
[4] Canberra Hosp, Med Phys & Radiat Engn, Garran, ACT 2605, Australia
关键词
Water equivalent diameter (D-W); Size-specific dose estimates (SSDE); Volume CT dose index (CTDIVOL); Patient dose; Patient table; ATTENUATION-BASED ESTIMATION; RAY COMPUTED-TOMOGRAPHY; PEDIATRIC CHEST CT; INDEX; IMPLEMENTATION; DIAMETER; MEDICINE; PURPOSE; CANCER; RISKS;
D O I
10.1007/s13246-016-0497-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of parameters water equivalent diameter (D-W) and size-specific dose estimate (SSDE) are becoming increasingly established as a recognised method to relate patient dose from a CT examination to the dose indicator volume CT dose index (CTDIVOL). However, the role of the attenuation due to the patient table in these estimations requires careful consideration and is the subject of this study. The aim of this study is to investigate the impact of a minimal part of the patient table when calculating the D-W and SSDE. We investigated 164 patients who had undergone CT examinations for the pelvis, abdomen, thorax and head. We subsequently calculated D-W and SSDE using two methods: one using a small circular region of interest (ROI) including a minimal part of the patient table and the other using a ROI fitted to the patient border alone. The results showed that the water equivalent diameter calculated with the table included in the ROI (D-W,D- t) is greater, compared to that without the consideration of the patient table (D-W,D- nt), by 1.5-6.2% depending on the anatomy being imaged. On the other hand, the SSDE calculated with inclusion of the patient table (SSDEt) is smaller than otherwise (SSDEnt) by 1.0-5.5% again depending on the anatomy being imaged. The effect of the patient table on D-W and SSDE in the thorax CT examination was statistically significant, but its effect on D-W and SSDE in the other examinations of head, pelvis and abdomen was relatively small and not statistically significant.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 50 条
  • [31] A fully automated calculation of size-specific dose estimates (SSDE) in thoracic and head CT examinations
    Anam, C.
    Haryanto, F.
    Widita, R.
    Arif, I.
    Dougherty, G.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [32] A Body Mass Index-Based Method for Size-Specific Dose Estimates (SSDE) in Adults
    Yan, D.
    Chen, B.
    Lu, W.
    Qiu, J.
    Shi, L.
    MEDICAL PHYSICS, 2020, 47 (06) : E507 - E507
  • [33] SIZE-specific dose estimate for lower-limb CT
    Kobayashi, Masanao
    Nishihara, Yusei
    Haba, Tomonobu
    Matsunaga, Yuta
    Asada, Yasuki
    Kobayashi, Shigeki
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (04) : 1183 - 1191
  • [34] A comparison study of size-specific dose estimate calculation methods
    Parikh, Roshni A.
    Wien, Michael A.
    Novak, Ronald D.
    Jordan, David W.
    Klahr, Paul
    Soriano, Stephanie
    Ciancibello, Leslie
    Berlin, Sheila C.
    PEDIATRIC RADIOLOGY, 2018, 48 (01) : 56 - 65
  • [35] SIZE-specific dose estimate for lower-limb CT
    Masanao Kobayashi
    Yusei Nishihara
    Tomonobu Haba
    Yuta Matsunaga
    Yasuki Asada
    Shigeki Kobayashi
    Physical and Engineering Sciences in Medicine, 2022, 45 : 1183 - 1191
  • [36] A comparison study of size-specific dose estimate calculation methods
    Roshni A. Parikh
    Michael A. Wien
    Ronald D. Novak
    David W. Jordan
    Paul Klahr
    Stephanie Soriano
    Leslie Ciancibello
    Sheila C. Berlin
    Pediatric Radiology, 2018, 48 : 56 - 65
  • [37] DEVELOPMENT OF RADIATION DOSE CALCULATION SOFTWARE USING THE SIZE-SPECIFIC DOSE ESTIMATE
    Shohji, Tomokazu
    Tachibana, Atsushi
    Higuchi, Sousuke
    Nakata, Norio
    Hayashi, Daichi
    Katoh, Yo
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (03) : 359 - 369
  • [38] Patient size matters: Effect of tube current modulation on size-specific dose estimates (SSDE) and image quality in low-dose lung cancer screening CT
    Barreto, Izabella
    Verma, Nupur
    Quails, Nathan
    Olguin, Catherine
    Correa, Nathalie
    Mohammed, Tan-Lucien
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (04): : 87 - 94
  • [39] PATIENT DOSE SURVEY BASED ON SIZE-SPECIFIC DOSE ESTIMATE AND ACCEPTABLE QUALITY DOSE IN CHEST AND ABDOMEN/PELVIS CT EXAMINATIONS
    Mehdipour, Ali
    Parsi, Masoumeh
    Khorram, Faezeh-Sadat
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (02) : 176 - 182
  • [40] Consideration of the usefulness of a size-specific dose estimate in pediatric CT examination
    Tsujiguchi, Takakiyo
    Obara, Hideki
    Ono, Shuichi
    Saito, Yoko
    Kashiwakura, Ikuo
    JOURNAL OF RADIATION RESEARCH, 2018, 59 (04) : 430 - 435