Agreement and repeatability of pupillometry using videokeratography and infrared devices

被引:45
|
作者
Wachler, BSB
Krueger, RR
机构
[1] Univ Calif Los Angeles, Jules Stein Eye Inst, Dept Ophthalmol, Los Angeles, CA 90095 USA
[2] Cleveland Eye Clin, Dept Ophthalmol, Cleveland, OH USA
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2000年 / 26卷 / 01期
关键词
D O I
10.1016/S0886-3350(99)00331-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the accuracy and repeatability of the pupil-measuring modules of several corneal topography devices. Setting: Department of Ophthalmology, Saint Louis University Eye Institute, St. Louis, Missouri, USA. Methods: In 14 eyes of 7 healthy myopic patients, pupillometry was performed with 3 corneal topography devices and with an infrared pupillometer under luminance-matched conditions for the Placido projection of the topography devices. Pupils were also measured under a mesopic condition. Outcomes were pupil diameters, limits of agreement, and coefficient of repeatability of the topography devices. Results: Mean pupil diameter measurements with the Technomed C-Scan, Humphrey Masterview, Alcon EyeMap, and under a mesopic condition were 3.35 mm, 2.96 mm, 2.34 mm, and 5.94 mm, respectively. All pupil diameter measurements differed significantly from one another except those by the Masterview and C-Scan devices. The mean difference between the C-Scan and luminance-matched infrared measurements was 0.74 mm and between the Masterview and luminance-matched infrared measurements, 0.27 mm. The limits of agreement +/-2 standard deviations was 4.12 mm and 1.56 mm for the C-Scan and Masterview devices, respectively. Coefficients of repeatability were 0.56 mm, 0.46 mm, and 0.44 mm for the C-Scan, Masterview, and EyeMap devices, respectively. Conclusions: Although topography pupillometry was repeatable, it underestimated the largest natural pupil diameter because of the luminance of the Placido rings. The difference in limits of agreement between the C-Scan and Masterview devices may be explained by pupil physiology and the static nature of videokeratoscopy. These results have implications when topography pupillometry is used to assess pupil diameters prior to refractive surgery. We do not recommend using pupil diameters measured by topography to preoperatively determine halo-related safety. J Cataract Refract Surg 2000; 26:35-40 (C) 2000 ASCRS and ESCRS.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 50 条
  • [21] Agreement and repeatability of central corneal thickness measurements by four different optical devices and an ultrasound pachymeter
    Gokcinar, Nesrin Buyuktortop
    Yumusak, Erhan
    Ornek, Nurgul
    Yorubulut, Serap
    Onaran, Zafer
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (07) : 1589 - 1598
  • [22] Agreement and repeatability of central corneal thickness measurements by four different optical devices and an ultrasound pachymeter
    Nesrin Buyuktortop Gokcinar
    Erhan Yumusak
    Nurgul Ornek
    Serap Yorubulut
    Zafer Onaran
    International Ophthalmology, 2019, 39 : 1589 - 1598
  • [23] Repeatability, reproducibility, agreement characteristics of 2 SD-OCT devices for anterior chamber angle
    Akil, Handan
    Dastiridou, Anna
    Marion, Kenneth
    Francis, Brian
    Chopra, Vikas
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2017, 52 (02): : 166 - 170
  • [25] Scotopic pupil size in a normal pediatric population using infrared pupillometry
    Eva-Maria Kohnen
    Alina A. Zubcov
    Thomas Kohnen
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2004, 242 : 18 - 23
  • [26] Measurement Agreement (Repeatability) for a Countermovement Jump Protocol Using a Portable Forceplate
    Williams, Morgan D.
    Bradshaw, Elizabeth J.
    Maschette, Wayne E.
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2007, 2 (04) : 445 - 448
  • [27] Repeatability and agreement of CCT measurement in myopia using entacam and ultrasound pachymetry
    Luo, Yong-Heng
    Zhong, Qian
    Ouyang, Ping-Bo
    Guo, Xian-Jian
    Duan, Xuan-Chu
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2012, 5 (03) : 329 - 333
  • [28] Scotopic pupil size in a normal pediatric population using infrared pupillometry
    Kohnen, EM
    Zubcov, AA
    Kohnen, T
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2004, 242 (01) : 18 - 23
  • [29] Portable infrared pupillometry in critical care
    Merlin D. Larson
    Vineeta Singh
    Critical Care, 20
  • [30] Portable infrared pupillometry in critical care
    Larson, Merlin D.
    Singh, Vineeta
    CRITICAL CARE, 2016, 20