A novel valveless rotary pump for cardiac assist

被引:0
|
作者
Rosenfeldt, FL [1 ]
Ostberg, BN [1 ]
Tcherkas, DD [1 ]
PastorizaPinol, JV [1 ]
Southwell, JE [1 ]
机构
[1] ALFRED HOSP,PRAHRAN,VIC 3181,AUSTRALIA
关键词
rotary pump; pulsatile; nonpulsatile;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe the design and preliminary testing of a novel pump designed for cardiac assist. It is a valveless rotary pump that can generate pulsatile or nonpulsatile output. The basis of the pump design is a cylindrical cavity swept by a vane sliding in a rotating disc. During rotation, rollers at the ends of the vane are in constant contact with the internal wall of the cavity so that a fluid-containing space is swept around the cavity from the inflow to the outflow ports. Bench tests showed that the output was relatively independent of the outflow resistance at pressures up to 100 mm Hg. In tests in dogs, the pimp performed satisfactorily as a left ventricular assist device and as a pump for total cardiopulmonary bypass. We believe that this simple pump design has potential as a left ventricular assist device or total artificial heart and merits further investigation.
引用
收藏
页码:420 / 425
页数:6
相关论文
共 50 条
  • [31] Theoretical analysis of novel valveless piezoelectric pump with cluster of unsymmetrical hump structure
    Xia, Qi-Xiao
    Zhang, Jian-Hui
    Lei, Hong
    Wang, Shou-Yin
    Cheng, Wei
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2008, 16 (12): : 2391 - 2397
  • [32] Design and Simulation of a Valveless Micro Pump
    Dau, Van Thanh
    Dinh, Thien Xuan
    Tanaka, Katsuhiko
    Sugiyama, Susumu
    JOURNAL OF ADVANCED MECHANICAL DESIGN SYSTEMS AND MANUFACTURING, 2009, 3 (01): : 69 - 75
  • [33] A piezoelectric valveless pump with flexible actuators
    Chen, Song
    Zhang, Jie
    Huang, Zijian
    Wang, Liewei
    Liu, Haidong
    Meng, Fanxu
    Kan, Junwu
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2023, 34 (12) : 1455 - 1462
  • [34] FLEXIBLE VALVELESS PUMP FOR BIO APPLICATIONS
    Naghdi, Masoud
    Farzbod, Farhad
    Goggans, Paul M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 10, 2020,
  • [35] Dielectric elastomer actuator-based valveless pump as Fontan failure assist device: introduction and preliminary study
    Benouhiba, Amine
    Walter, Armando
    Jahren, Silje Ekroll
    Martinez, Thomas
    Clavica, Francesco
    Heinisch, Paul Philipp
    Obrist, Dominik
    Civet, Yoan
    Perriard, Yves
    INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY, 2024, 38 (04):
  • [36] Features of the Design of a Valveless Spur Pump
    A. V. Grigor’ev
    G. A. Nesterenko
    Chemical and Petroleum Engineering, 2020, 55 : 996 - 1002
  • [37] Simulation of a valveless pump with an elastic tube
    Shin, Soo Jai
    Chang, Cheong Bong
    Sung, Hyung Jin
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2012, 38 : 13 - 23
  • [38] Physiology of continuous blood flow in recipients of rotary cardiac assist devices
    Thalmann, M
    Schima, H
    Wieselthaler, G
    Wolner, E
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (03): : 237 - 245
  • [39] Features of the Design of a Valveless Spur Pump
    Grigor'ev, A. V.
    Nesterenko, G. A.
    CHEMICAL AND PETROLEUM ENGINEERING, 2020, 55 (11-12) : 996 - 1002
  • [40] PULSATILE CONTROL OF ROTARY BLOOD PUMP AND CARDIAC WORKLOAD Reply
    Pirbodaghi, Tohid
    Axiak, Shannon
    Weber, Alberto
    Vandenberghe, Stijn
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (04): : 1145 - 1146