A novel valveless rotary pump for cardiac assist

被引:0
|
作者
Rosenfeldt, FL [1 ]
Ostberg, BN [1 ]
Tcherkas, DD [1 ]
PastorizaPinol, JV [1 ]
Southwell, JE [1 ]
机构
[1] ALFRED HOSP,PRAHRAN,VIC 3181,AUSTRALIA
关键词
rotary pump; pulsatile; nonpulsatile;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe the design and preliminary testing of a novel pump designed for cardiac assist. It is a valveless rotary pump that can generate pulsatile or nonpulsatile output. The basis of the pump design is a cylindrical cavity swept by a vane sliding in a rotating disc. During rotation, rollers at the ends of the vane are in constant contact with the internal wall of the cavity so that a fluid-containing space is swept around the cavity from the inflow to the outflow ports. Bench tests showed that the output was relatively independent of the outflow resistance at pressures up to 100 mm Hg. In tests in dogs, the pimp performed satisfactorily as a left ventricular assist device and as a pump for total cardiopulmonary bypass. We believe that this simple pump design has potential as a left ventricular assist device or total artificial heart and merits further investigation.
引用
收藏
页码:420 / 425
页数:6
相关论文
共 50 条
  • [21] Necessity of Telemonitoring in Patients Treated by Means of Cardiac Assist Systems on the Example of Polish Rotary Blood Pump ReligaHeart ROT
    Gawlikowski, Maciej
    Kustosz, Roman
    Gonsior, Malgorzata
    Czak, Miroslaw
    Kurtyka, Przemyslaw
    Pacholewicz, Jerzy
    Zakliczynski, Michal
    Kapelak, Boguslaw
    Wierzbicki, Karol
    Siondalski, Piotr
    INNOVATIONS IN BIOMEDICAL ENGINEERING, 2019, 925 : 85 - 95
  • [22] Minimally Invasive Flow Estimation for a Rotary Cardiac Assist Device
    Yu, Yih-Choung
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 3, 2010, : 600 - 605
  • [23] Cardiac transplant or rotary blood pump: Contemporary evidence
    Westaby, Stephen
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (01): : 24 - 31
  • [24] Ischemic cardiomyopathy: cardiac transplant or rotary blood pump?
    Westaby, S.
    CARDIOLOGY, 2013, 126 : 53 - 53
  • [25] The estimation of cardiac function from the rotary blood pump
    Nakata, K
    Shiono, M
    Akiyama, K
    Orime, Y
    Saito, A
    Tutomu, H
    Negishi, N
    Sezai, Y
    Sankai, T
    ARTIFICIAL ORGANS, 2001, 25 (09) : 709 - 712
  • [26] PULSATILE CONTROL OF ROTARY BLOOD PUMP AND CARDIAC WORKLOAD
    Arakawa, Mamoru
    Tatsumi, Eisuke
    Nishimura, Takashi
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (04): : 1144 - 1145
  • [27] Performance of a new implantable cardiac assist centrifugal pump
    Tevaearai, HT
    Mueller, XM
    Jegger, D
    Augsburger, M
    Burki, M
    von Segesser, LK
    ARTIFICIAL ORGANS, 2001, 25 (01) : 67 - 69
  • [28] In vitro testing of a new implantable ventricular assist rotary pump made in China
    Li, Jingxing
    Li, Guorong
    Zhu, Xiaodong
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2000, 17 (03): : 259 - 261
  • [29] Cora rotary pump for implantable left ventricular assist device: Biomaterial aspects
    Monties, JR
    Dion, I
    Havlik, P
    Rouais, F
    Trinkl, J
    Baquey, C
    ARTIFICIAL ORGANS, 1997, 21 (07) : 730 - 734
  • [30] Hemodynamic modes of ventricular assist with a rotary blood pump: Continuous, pulsatile, and failure
    Vandenberghe, S
    Segers, P
    Antaki, JF
    Meyns, B
    Verdonck, PR
    ASAIO JOURNAL, 2005, 51 (06) : 711 - 718