Impact of impinging jet ventilation on thermal comfort and indoor air quality in office buildings

被引:63
|
作者
Staveckis, Arturs [1 ,2 ]
Borodinecs, Anatolijs [1 ]
机构
[1] Riga Tech Univ, Kalku Iela H 1, LV-1658 Riga, Latvia
[2] Tech Univ Berlin, Str 17 Juni 135, D-10623 Berlin, Germany
关键词
Air parameters; Impinging jet ventilation; Office buildings; Thermal comfort; Ventilation effectiveness;
D O I
10.1016/j.enbuild.2021.110738
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper is dedicated to research of impinging jet (IJV) air distribution method. This system provides the desired indoor climate in office buildings. This paper describes the experimental requirements and boundary conditions for the CFD simulation and experiment in the climate chamber. The necessary modelling scenarios were developed to review the operation of the ventilation system according to different climatic conditions (winter, summer), human positions in the room and the shape of the supply duct. It is concluded that the shape of the air opening has little effect on the contaminant and heat removal effectiveness, 114%-122% and 1.12-1.16 respectively. At the same time, there is a large impact on the air exchange effectiveness (0.74-0.91). It was experimentally noted that in terms of contaminant removal and air exchange effectiveness, the circular opening provides better results. The human position depends on the supply temperature and flow velocity. By analyzing different scenarios, it was determined that the minimum acceptable distance to maintain thermal comfort within the standard requirements from the supply outlet is 1.7 m. As the distance from the air opening increases, the vertical air temperature difference at the height of 0.1-1.1 m decreases more than 2 times - from 1.9 K/m to 0.7 K/m. It is concluded that impinging jet ventilation has a great potential for use in office spaces both in winter and summer scenarios. This system significantly improves thermal comfort and indoor air quality. Applying impinging jet ventilation (IJV), limitations and peculiarities of the system such as supply air velocity, temperature and shape of the air duct must be carefully evaluated. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] A review on windcatcher for passive cooling and natural ventilation in buildings, Part 1: Indoor air quality and thermal comfort assessment
    Jomehzadeh, Fatemeh
    Nejat, Payam
    Calautit, John Kaiser
    Yusof, Mohd Badruddin Mohd
    Zaki, Sheikh Ahmad
    Hughes, Ben Richard
    Yazid, Muhammad Noor Afiq Witri Muhammad
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 70 : 736 - 756
  • [32] Modeling of Subjective Responses to Indoor Air Quality and Thermal Conditions in Office Buildings
    Kostiainen, T.
    Welling, I.
    Lahtinen, M.
    Salmi, K.
    Kahkonen, E.
    Lampinen, J.
    HVAC&R RESEARCH, 2008, 14 (06): : 905 - 923
  • [33] Experimental assessment of the impact of natural ventilation on indoor air quality and thermal comfort conditions of educational buildings in the Eastern Mediterranean region during the heating period
    Heracleous, C.
    Michael, A.
    JOURNAL OF BUILDING ENGINEERING, 2019, 26
  • [34] Impact of windcatcher on the thermal comfort and indoor air quality in a modern house
    Mamari, Manal Al
    Khan, Hayder Murad
    Al Saadi, Saleh
    Al Hashim, Alya
    BUILDING RESEARCH AND INFORMATION, 2025, 53 (1-2): : 204 - 219
  • [35] Improving indoor air quality and thermal comfort in office building by using combination filters
    Kabrein, H.
    Yusof, M. Z. M.
    Hariri, A.
    Leman, A. M.
    Afandi, A.
    2ND INTERNATIONAL CONFERENCE ON COMPUTATIONAL FLUID DYNAMICS IN RESEARCH AND INDUSTRY (CFDRI 2017), 2017, 243
  • [36] Thermal and air quality comfort of office buildings based on new principles of dimensioning in Hungary
    Kajtár, László
    Erdosi, István
    Bakó-Bíró, Zsolt
    Periodica Polytechnica Mechanical Engineering, 2000, 44 (02): : 265 - 274
  • [37] IMPACT OF REDUCED INFILTRATION AND VENTILATION ON INDOOR AIR-QUALITY IN RESIDENTIAL BUILDINGS
    HOLLOWELL, CD
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1978, 20 (12): : 60 - 60
  • [38] A Comprehensive Assessment of Indoor Air Quality and Thermal Comfort in Educational Buildings in the Mediterranean Climate
    Miao, S.
    Gangolells, M.
    Tejedor, B.
    INDOOR AIR, 2023, 2023
  • [39] Comparison of indoor air quality and thermal comfort standards and variations in exceedance for school buildings
    Babich, Francesco
    Torriani, Giulia
    Corona, Jacopo
    Lara-Ibeas, Irene
    JOURNAL OF BUILDING ENGINEERING, 2023, 71
  • [40] Indoor air quality, thermal comfort and ventilation in deep energy retrofitted Irish dwellings
    Coggins, Ann Marie
    Wemken, Nina
    Mishra, Asit Kumar
    Sharkey, Martin
    Horgan, Liam
    Cowie, Hilary
    Bourdin, Emmanuel
    McIntyre, Brian
    Building and Environment, 2022, 219