Impact of impinging jet ventilation on thermal comfort and indoor air quality in office buildings

被引:63
|
作者
Staveckis, Arturs [1 ,2 ]
Borodinecs, Anatolijs [1 ]
机构
[1] Riga Tech Univ, Kalku Iela H 1, LV-1658 Riga, Latvia
[2] Tech Univ Berlin, Str 17 Juni 135, D-10623 Berlin, Germany
关键词
Air parameters; Impinging jet ventilation; Office buildings; Thermal comfort; Ventilation effectiveness;
D O I
10.1016/j.enbuild.2021.110738
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper is dedicated to research of impinging jet (IJV) air distribution method. This system provides the desired indoor climate in office buildings. This paper describes the experimental requirements and boundary conditions for the CFD simulation and experiment in the climate chamber. The necessary modelling scenarios were developed to review the operation of the ventilation system according to different climatic conditions (winter, summer), human positions in the room and the shape of the supply duct. It is concluded that the shape of the air opening has little effect on the contaminant and heat removal effectiveness, 114%-122% and 1.12-1.16 respectively. At the same time, there is a large impact on the air exchange effectiveness (0.74-0.91). It was experimentally noted that in terms of contaminant removal and air exchange effectiveness, the circular opening provides better results. The human position depends on the supply temperature and flow velocity. By analyzing different scenarios, it was determined that the minimum acceptable distance to maintain thermal comfort within the standard requirements from the supply outlet is 1.7 m. As the distance from the air opening increases, the vertical air temperature difference at the height of 0.1-1.1 m decreases more than 2 times - from 1.9 K/m to 0.7 K/m. It is concluded that impinging jet ventilation has a great potential for use in office spaces both in winter and summer scenarios. This system significantly improves thermal comfort and indoor air quality. Applying impinging jet ventilation (IJV), limitations and peculiarities of the system such as supply air velocity, temperature and shape of the air duct must be carefully evaluated. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Indoor air quality in urban office buildings
    Faria, T.
    Almeida-Silva, M.
    Dias, Ana
    Almeida, S. M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL TECHNOLOGY AND MANAGEMENT, 2016, 19 (3-4) : 236 - 256
  • [22] Enhancing indoor air quality and thermal comfort in indoor swimming pool facilities: investigating the impact of ventilation system configurations
    Hanafi A.M.
    Ibrahim M.A.
    Abou-deif T.M.
    Morcos S.M.
    Journal of Engineering and Applied Science, 2023, 70 (01):
  • [23] Advances in research for underground buildings: Energy, thermal comfort and indoor air quality
    Yu, Jia
    Kang, Yanming
    Zhai, Zhiqiang
    ENERGY AND BUILDINGS, 2020, 215
  • [24] Investigation of indoor air quality and thermal comfort condition in airport terminal buildings
    Akyuz, Mehmet Kadri
    Kafali, Hasim
    Altuntas, Onder
    AIRCRAFT ENGINEERING AND AEROSPACE TECHNOLOGY, 2021, 93 (01): : 25 - 34
  • [25] NUMERICAL INVESTIGATIONS OF EFFECT OF INDOOR AIR QUALITY ON THERMAL COMFORT IN RESIDENTIAL BUILDINGS
    Krzaczek, M.
    Tejchman, J.
    ARCHIVES OF CIVIL ENGINEERING, 2014, 60 (01) : 91 - 121
  • [26] Study of indoor local thermal comfort for impinging jet ventilation combined with ductless personalized ventilation under different cooling loads
    Duan, Tao
    Ye, Xiao
    Du, Peng
    Qi, Hechuang
    Kang, Yanming
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2024, 265
  • [27] INDOOR AIR-QUALITY AND HEALTH IN 2 OFFICE BUILDINGS WITH DIFFERENT VENTILATION SYSTEMS
    HEDGE, A
    STERLING, TD
    STERLING, EM
    COLLETT, CW
    STERLING, DA
    NIE, V
    ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) : 115 - 128
  • [28] Numerical study of Indoor Air Quality and thermal comfort under stratum ventilation
    Tian, Lin
    Lin, Zhang
    Liu, Jing
    Wang, Qiuwang
    PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2008, 8 (7-8): : 541 - 548
  • [29] Computational investigation on the factors influencing thermal comfort for impinging jet ventilation
    Chen, Huijuan
    Moshfegh, Bahram
    Cehlin, Mathias
    BUILDING AND ENVIRONMENT, 2013, 66 : 29 - 41
  • [30] Effects of combined central air conditioning diffusers and window-integrated ventilation system on indoor air quality and thermal comfort in an office
    Park, Dong Yoon
    Chang, Seongju
    SUSTAINABLE CITIES AND SOCIETY, 2020, 61