Reproducibility and accuracy of measurements with a hand held autorefractor in children

被引:64
|
作者
Harvey, EM
Miller, JM
Wagner, LK
Dobson, V
机构
[1] UNIV ARIZONA, CTR OPT SCI, TUCSON, AZ 85719 USA
[2] UNIV ARIZONA, DEPT PSYCHOL, TUCSON, AZ 85719 USA
关键词
D O I
10.1136/bjo.81.11.941
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim-To determine reproducibility and accuracy of the Nikon Retinomax autorefractor when used with children who were made cycloplegic. Methods-Autorefraction and retinoscopy or subjectively refined retinoscopy (where, under the patient's direction, the refraction was varied until the best visual acuity was achieved) were performed on the right eye of 47 children, age 11-93 months. Autorefraction was performed using the Nikon Retinomax, which provides up to eight measured values of refractive error and one representative measurement of refractive error. Results-Autorefractor measurements were successfully obtained from 7/9 children age 3 years or younger, and from all older children. Vector methods were used to calculate differences. Retinomax reproducibility averaged 0.43 D. Unbiased Retinomax and retinoscopy measurements differed by an average of 0.82 D. Unbiased Retinomax and subjectively refined retinoscopy differed by an average of 1.03 D. Conclusions-Reproducibility of Retinomax measured values in children is comparable with reproducibility of retinoscopy, subjective refraction, and autorefraction measurements in adults. Agreement between Retinomax and retinoscopy and agreement between Retino-MATERIALS max and subjective refinement in children is comparable with agreement between autorefraction and subjective refraction in adults. The study indicates that the Retinomax is a useful instrument for measuring refractive errors in young children.
引用
收藏
页码:941 / 948
页数:8
相关论文
共 50 条
  • [41] LONG-TERM STABILITY OF HAND-HELD DYNAMOMETRIC MEASUREMENTS IN CHILDREN WHO HAVE MYELOMENINGOCELE
    EFFGEN, SK
    BROWN, DA
    PHYSICAL THERAPY, 1992, 72 (06): : 458 - 465
  • [42] Criteria for assessing autorefractor accuracy and accommodation - Reply
    Wesemann, W
    Dick, B
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (07): : 945 - 946
  • [43] Reproducibility of nearwork-induced transient myopia measurements using the WAM-5500 autorefractor in its dynamic mode
    Lin, Zhong
    Vasudevan, Balamurali
    Zhang, Yi Cao
    Qiao, Li Ya
    Liang, Yuan Bo
    Wang, Ning Li
    Ciuffreda, Kenneth J.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (10) : 1477 - 1483
  • [44] ARE HAND-HELD TCD MEASUREMENTS ACCEPTABLE FOR ESTIMATES OF CBFv?
    Saeed, Nazia P.
    Panerai, Ronney B.
    Robinson, Thompson G.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (10): : 1839 - 1844
  • [45] Reproducibility of Optical Coherence Tomography Measurements in Children
    Altemir, Irene
    Pueyo, Victoria
    Elia, Noemi
    Polo, Vicente
    Larrosa, Jose M.
    Oros, Daniel
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (01) : 171 - 176
  • [46] Using Hand-Held Arrays for Automotive NVH Measurements
    Gade, Svend
    Gomes, Jesper
    Hald, Jorgen
    SOUND AND VIBRATION, 2014, 48 (03): : 12 - 16
  • [47] Reproducibility of nearwork-induced transient myopia measurements using the WAM-5500 autorefractor in its dynamic mode
    Zhong Lin
    Balamurali Vasudevan
    Yi Cao Zhang
    Li Ya Qiao
    Yuan Bo Liang
    Ning Li Wang
    Kenneth J. Ciuffreda
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2012, 250 : 1477 - 1483
  • [48] Accuracy and reproducibility of 3-dimensional digital model measurements
    Sousa, Marines Vieira S.
    Vasconcelos, Eliziane Cossetin
    Janson, Guilherme
    Garib, Daniela
    Pinzan, Arnaldo
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (02) : 269 - 273
  • [49] Reassessing the accuracy and reproducibility of Diers formetric measurements in healthy volunteers
    Lason, Gregoire
    Peeters, Luc
    Vandenberghe, Koen
    Byttebier, Geert
    Comhaire, Frank
    INTERNATIONAL JOURNAL OF OSTEOPATHIC MEDICINE, 2015, 18 (04) : 247 - 254
  • [50] Accuracy of hand-held ultrasound scanning in detecting meniscal tears
    Shetty, A. A.
    Tindall, A. J.
    James, K. D.
    Relwani, J.
    Fernando, K. W.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (08): : 1045 - 1048