Reproducibility and accuracy of measurements with a hand held autorefractor in children

被引:64
|
作者
Harvey, EM
Miller, JM
Wagner, LK
Dobson, V
机构
[1] UNIV ARIZONA, CTR OPT SCI, TUCSON, AZ 85719 USA
[2] UNIV ARIZONA, DEPT PSYCHOL, TUCSON, AZ 85719 USA
关键词
D O I
10.1136/bjo.81.11.941
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim-To determine reproducibility and accuracy of the Nikon Retinomax autorefractor when used with children who were made cycloplegic. Methods-Autorefraction and retinoscopy or subjectively refined retinoscopy (where, under the patient's direction, the refraction was varied until the best visual acuity was achieved) were performed on the right eye of 47 children, age 11-93 months. Autorefraction was performed using the Nikon Retinomax, which provides up to eight measured values of refractive error and one representative measurement of refractive error. Results-Autorefractor measurements were successfully obtained from 7/9 children age 3 years or younger, and from all older children. Vector methods were used to calculate differences. Retinomax reproducibility averaged 0.43 D. Unbiased Retinomax and retinoscopy measurements differed by an average of 0.82 D. Unbiased Retinomax and subjectively refined retinoscopy differed by an average of 1.03 D. Conclusions-Reproducibility of Retinomax measured values in children is comparable with reproducibility of retinoscopy, subjective refraction, and autorefraction measurements in adults. Agreement between Retinomax and retinoscopy and agreement between Retino-MATERIALS max and subjective refinement in children is comparable with agreement between autorefraction and subjective refraction in adults. The study indicates that the Retinomax is a useful instrument for measuring refractive errors in young children.
引用
收藏
页码:941 / 948
页数:8
相关论文
共 50 条
  • [21] Screening for amblyopia with a hand-held autorefractor in pre-school children: automated data interpretation with the aid of a neural network system
    Angi, MF
    Sturaro, M
    Pandin, M
    Didone, G
    PERCEPTION, 1997, 26 (06) : 770 - 771
  • [22] Screening for refractive errors in children: accuracy of the hand held refractor Retinomax to screen for astigmatism
    Cordonnier, M
    Dramaix, M
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (02) : 157 - 161
  • [23] Plusoptix Vision Screener: the accuracy and repeatability of refractive measurements using a new autorefractor
    Dahlmann-Noor, A. H.
    Comyn, O.
    Kostakis, V.
    Misra, A.
    Gupta, N.
    Heath, J.
    Brown, J.
    Iron, A.
    McGill, S.
    Vrotsou, K.
    Vivian, A. J.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (03) : 346 - 349
  • [24] Effectiveness of screening for refractive errors with a hand-held autorefractor in a preschool population with a high prevalence of astigmatism
    Harvey, EM
    Miller, JM
    Dobson, V
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4529 - 4529
  • [25] Non-cycloplegic screening for amblyopia via refractive findings with the Nikon Retinomax hand held autorefractor in 3 year old kindergarten children
    Barry, JC
    König, HH
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (10) : 1179 - 1182
  • [26] Accuracy and reproducibility of wavefront measurements with the aberrometer.
    Kaemmerer, M
    Mierdel, P
    Mrochen, M
    Seiler, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S679 - S679
  • [27] Instrument accuracy and reproducibility in measurements of pulmonary function
    Jensen, Robert L.
    Teeter, John G.
    England, Richard D.
    White, Heather J.
    Pickering, Eve H.
    Crapo, Robert O.
    CHEST, 2007, 132 (02) : 388 - 395
  • [28] Accuracy and reproducibility of TEE measurements of the ascending aorta
    Reich, DL
    Doshi, RR
    Ehrlich, M
    Konstadt, SN
    Ergin, MA
    ANESTHESIA AND ANALGESIA, 1999, 88 (02):
  • [29] Accuracy and reproducibility of ultrasound measurements in obstetric management
    Nakai, A
    Oya, A
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 2002, 54 (01) : 31 - 36
  • [30] Test accuracy of hand-held echocardiographic imaging
    Prinz, C.
    Dohrmann, J.
    Van Buuren, F.
    Bitter, T.
    Bogunovic, N.
    Horstkotte, D.
    Faber, L.
    EUROPEAN HEART JOURNAL, 2012, 33 : 856 - 857